Maryland Journeyman HVACR Exam Guide: The Credential, the Hundred-Question Sitting, and the Route Between Them

Maryland’s Journeyman HVACR license is issued by the State Board of Heating, Ventilation, Air-Conditioning, and Refrigeration Contractors, in the Maryland Department of Labor, under Title 9A of the Business Regulation Article. The examination, administered by PSI, is an open-book sitting of 100 questions in 240 minutes, passed at a 70% minimum passing score, on an outline the bulletin states is identical to the master examination’s. The PassProfessor Maryland Journeyman HVACR program prepares candidates for that sitting and the apprentice years that earn it.

This program is part of the expanding PassProfessor catalog — join the notify list and we’ll email you when enrollment opens.

The credential at a glance

ItemVerified position
ProgramMaryland Journeyman HVACR: the Journeyman examination for the journeyman heating, ventilation, air-conditioning, and refrigeration license
RegulatorState Board of Heating, Ventilation, Air-Conditioning, and Refrigeration Contractors, Maryland Department of Labor; Business Regulation Article, Title 9A; COMAR 09.15
Examination vendorPSI Services LLC, contracted by the Board; eligibility screening by PSI on application
Format and duration100 questions, computer-administered by appointment, 240 minutes
Book policyOpen book — published references only; no study guides
Passing standard70% minimum passing score
Eligibility gateAt least four years holding an apprentice license and at least 6,000 hours of training under the direction and control of a licensed contractor
Examination fee$150, paid directly to PSI
Board license fee$25, under COMAR 09.15.01.03B — separate from the examination fee
TermTwo years, expiring on the first October 1 in an odd-numbered year after the effective date
Continuing educationNone — no education hours are imposed on journeyman licensees
Administrator notePassProfessor is independent and is not affiliated with the State Board of HVACR Contractors or the Maryland Department of Labor

Maryland is the opposite kind of examination problem from a department-run sitting with unpublished mechanics. Here almost everything is published — the vendor, the count, the minutes, the outline to the question, the reference list to the edition — and the difficulty moves to a different layer: the published materials do not all agree with each other, and the statute does not agree with the bulletin at the single most consequential point, the eligibility gate. This guide is therefore organized as an exercise in layer discipline: bulletin for the sitting, statute and regulation for the license, and a clear account of which document governs when they diverge. The program page, Maryland Journeyman HVACR Exam Preparation, states the credential in brief; this guide works through it in full.

Reading the verified facts

Three layers carry Maryland’s facts. The statute, Title 9A, owns the credential: the six license classes, the definitions, the eligibility gates, the pass grade in its statutory form, the renewal calendar, the reciprocity conditions, and the discipline grounds. The Board’s regulations, COMAR 09.15, own the fees, the pre-examination gate in regulatory form, the post-examination licensure deadline, and the code-adoption chain. The PSI bulletin owns the sitting: the count, the minutes, the outline, the references, the book and tabbing rules, and the day-of mechanics. Where a layer speaks outside its ownership — most importantly, where the bulletin’s journeyman paragraph states an eligibility gate the statute contradicts — the owning layer governs, and this guide says so explicitly rather than averaging the two. One figure is deliberately absent: no pretest or unscored count for this examination is published in any layer, and none is printed.

The six-class ladder, and where the journeyman stands

Title 9A licenses exactly six classes of individual: master; master restricted; limited; journeyman; journeyman restricted; and apprentice. Maryland licenses individuals only — there is no business or entity license — so a business provides services through licensed individuals under a contractor-tier licensee. An individual shall be licensed before providing or assisting in providing HVACR services in the State.

The journeyman is defined by a single condition: a license to provide HVACR services while under the direction and control of a licensed contractor. The statute then closes the contracting door twice — a journeyman is not a licensed contractor, a term that expressly excludes apprentices and journeymen, and only a master, master restricted, or limited licensee can contract with the public and carry the contractor insurance duty — and performing services outside the scope of the journeyman license is a disciplinary ground in its own right. The credential is therefore unrestricted as to the kinds of HVACR work and restricted as to the capacity in which the work is done. The sibling tier must be separated at the outset, because Maryland’s most damaging factual error lives in the gap between them: the journeyman restricted license confines its holder to a single specialty area, is examined specialty by specialty, and carries its own, shorter eligibility gate; none of its figures belongs in this guide. Below the journeyman sits the apprentice, who assists while in training; anyone entering the trade must obtain an apprentice license, for which there are no prerequisites. Every class above apprentice is reached by examination, and there is no required course for an HVACR license examination.

The route, step by step

Step one — enter as an apprentice. Obtain the apprentice license, for which there are no prerequisites; the gate counts years holding that license, so the license itself, not merely the work, starts the clock. Step two — complete the statute gate. Accumulate at least four years as a licensed apprentice and at least 6,000 hours of training under the direction and control of a licensed contractor, taking any Board credits into account where they genuinely apply. Step three — apply to the testing service. Submit the application online with documentation uploaded and the $150 examination fee paid with it; an application without the fee is not processed, and approval arrives with scheduling instructions. Step four — sit and pass. Attend the computer-administered, open-book sitting with the five published references prepared within the tabbing rules, and reach the 70% minimum passing score; the result appears on screen at the end of the sitting. Step five — license within the year. Apply for original licensure with the $25 Board fee within one year of passing, or the test results cease to remain valid; the Board issues the license on receipt of the license fee, with no insurance proof required of the journeyman. Step six — hold and renew. Renew on the two-year, October-first, odd-year calendar, with no continuing education hours to accumulate — and, after any failed sitting, observe the thirty-day interval before sitting again.

The sitting in depth

The Board has contracted with PSI Services LLC to conduct its examination program, under a bulletin of record first copyrighted in 2024 and updated September 1, 2024. Application is online only — mail, fax, and email applications ceased to be processed after March 31, 2025 — with scheduling available online at any hour or by telephone, and qualification documentation uploaded with the application. Eligibility screening sits with the testing service: to be eligible to register, the applicant shall have satisfactorily completed the required work experience, and the testing service reviews the application to determine that the applicant meets all eligibility requirements. That sentence settles who screens, not which gate figure the screening applies — the gate itself is the statute’s, as the eligibility section of this guide sets out.

The sitting is administered by computer, by appointment, one question at a time, across 240 minutes for 100 questions. A tutorial of up to fifteen minutes runs before the examination and does not count against its time, and answers may be revisited and changed until time expires or the candidate ends the examination. Candidates arrive at least thirty minutes early, register under the legal name exactly as on their identification, and present one valid, unexpired, signature- and photo-bearing identification. Calculators are limited to non-programmable models — silent, battery-operated, without paper-tape printing and without an alphabetic keyboard — and a hardcover bound word-to-word translation dictionary, without pictures or definitions, is permitted; no other language provision for the examination is verified, and this guide states none.

Scoring is immediate. The passing or failing indication appears on screen at the end of the test, and results are otherwise confidential, revealed only to the candidate and to the Board and Department. A passing candidate receives no further notice from the testing service — licensing instructions come from the Department, and the one-year licensure fuse is already running. A failing candidate is given thirty minutes at the end of the examination to review the items missed, at no charge. The fee’s conditions are part of the sitting’s discipline: cancellation or rescheduling preserves the fee only with notice two days before the scheduled date (a Monday appointment requires notice by the previous Saturday), and voice mail is not an acceptable form of cancellation; missing the appointment, cancelling late, arriving too late, or lacking proper identification forfeits the fee; payment is valid for one examination only, fees are neither refundable nor transferable, and examination fees are valid for ninety days. No hands-on, practical, or drawing component is stated for this examination in the bulletin, the statute, the regulations, or the Department’s pages; the sourced examination is the computer-administered open-book sitting described here.

The pass standard, in its published forms

Maryland publishes its passing standard in three consistent forms, and this guide uses the bulletin’s form — 70% minimum passing score — as the headline, because that is the form attached to the examination the candidate sits. The bulletin’s score-reporting language states the same standard from the other side: a passing grade of 70 points is required to qualify for licensure. The statute carries it as a grade of at least 70 percent. Three documents, one standard, no conflict — a useful contrast with the eligibility gate, where the documents diverge and the statute must be followed. On a hundred-question sitting, seventy credited answers pass, and the outline weights show where those seventy must be gathered from.

The outline in full

The bulletin prints one six-topic outline for the journeyman examination and states that it is the same distribution as the master examination’s. The identity matters in both directions: the worker tier is examined across the contractor tier’s full subject range at the contractor tier’s weights, and a candidate who later climbs to the master examination will meet a familiar outline.

Electrical Knowledge, Motors, and Controls — 20. Alternating and direct current circuits; electric motors; controls. Piping — 15. Blueprints and schematics; materials, applications, and installation; joints and connections; hangers and supports; valves and fittings; testing and troubleshooting; piping insulation. Refrigeration and Air Conditioning — 25. Theory; refrigerants; equipment sizing and design; equipment and components; installation; system operation, troubleshooting, and maintenance — the largest topic, and the one the list’s single textbook principally serves. Heating Systems — 20. Theory and types; combustion air; equipment sizing; heating equipment; installation; operation, troubleshooting, and maintenance; steam, hydronics, and hydronic piping; vents and chimneys; fuel oil systems — examined through the mechanical code and the textbook, not through any separate fuel-gas volume. Air Distribution Systems — 15. Duct definitions, sizing, and design; assembly and installation; hangers and supports; materials and shapes; insulation; fire and smoke control; hoods and exhaust; testing and balancing; ventilation requirements; plans and symbols — the Ductulator’s topic, calculated rather than estimated in the sitting. Safety — 5. Material safety data; fall protection; trenches and excavations; contractor responsibilities; ladders; scaffolds — drawn from the construction-safety regulation on the reference list.

The references in full

Five references, and only five, are allowed in the testing room, and they will not be provided at the test center. The International Mechanical Code, with the bulletin’s operative instruction that, effective May 15, 2025, only the 2018 edition will be used. Modern Refrigeration and Air Conditioning, 21st or 22nd edition — the list’s textbook and the theory backbone of its largest topic. Manual J — Residential Load Calculation, 2006, Eighth Edition. The construction-safety regulation, 29 CFR Part 1926, with latest available amendments or in the testing service’s selections volume. And the ACCA Ductulator, present because air distribution sizing is performed, not recalled. The absences are as instructive as the entries: no fuel-gas code and no Maryland-specific volume appears on the list, although fuel work — combustion air, vents and chimneys, fuel oil systems — is examined through the mechanical code and the textbook.

The book rules govern how those five items may be prepared. No study guides are allowed. Books may be indexed and may contain highlighted or underlined text; all materials must be unmarked, not written in, and may contain no additional papers, loose or attached. Tabs are permitted only in specified permanent forms — named self-adhesive permanent plastic tabs and permanent adhesive index tabs are acceptable, flag-style tabs are expressly unacceptable — and the enforcement test is physical: if the proctor can remove a tab without ripping the page, the candidate removes the tabs before taking the examination.

Tested edition against field edition

The examination code is the International Mechanical Code, 2018 edition. The field code is reached by a chain candidates should be able to recite without collapsing it: the Board’s compliance regulation, amended effective April 13, 2026, adopts the most recent version of the mechanical code as incorporated in the Model Performance Code, which currently incorporates the 2021 edition; that code is not binding on a subdivision unless the subdivision adopts it; the Board enforces its code through county cooperative agreements; and a county code adopted before January 1, 1988 continues to apply within that county. The Maryland Building Performance Standards adopt neither the mechanical code nor any fuel-gas code. The field position is therefore genuinely local in a way the examination position is not: one edition in the room, a 2021 pointer in the chain, and county-level adoption and enforcement on the ground. Candidates are tested on 2018, and any item keyed to the 2021 edition as the examination answer is keyed to the wrong layer.

Eligibility in depth: the statute gate, the credits, and the one exemption

The journeyman gate, in the statute’s own construction, has two limbs and an examination. The applicant shall have held, for a period of at least four years, an apprentice license, and during that period shall have completed at least 6,000 hours of training in providing HVACR services under the direction and control of a licensed contractor; and the applicant shall pass an examination. The Board’s regulation restates the same gate as a precondition of being examined, and the Department’s licensing requirements page agrees. That agreement is what makes the bulletin’s divergent journeyman paragraph identifiable as an error rather than a conflict: the paragraph prints a three-year period with a much smaller total of training hours — the figures the statute assigns to the journeyman restricted gate — in the journeyman section. This guide does not reproduce those figures as a journeyman requirement in any form, does not present the paragraph as an alternative gate, and does not speculate about which figure any screener applies at intake, because no source verifies the screening practice. Applicants plan on the statute: four years, six thousand hours, under a licensed contractor, as a licensed apprentice.

The Board’s credit powers soften the gate at its edges, each with a stated ceiling: not more than three years for a formal course of study or professional training the Board finds comparable; not more than six years for work experience that falls short of the stated requirements where the work provided comparable experience and the shortfall is not attributable to the applicant’s fault or neglect; and not more than three years for an applicant who has been teaching formal HVACR courses of study. A separate bulletin passage describing a Board application route on at least three years of qualifying experience among its fallback routes is recorded here as bulletin context only, never as the statutory gate. One exemption from the examination itself survives, and it is genuine: the Board shall issue a journeyman license without examination to an individual who has successfully completed an HVACR apprentice program approved by the Apprenticeship and Training Council and applies within two years of graduation, the window the bulletin and the regulation both attach. Every other without-examination route in the older statute is a spent transition provision, and none is presented as an available route. Post-examination, the successful applicant shall apply for licensure, with all applicable fees, within one year of passing for the results to remain valid, and on qualification the Board issues the license on receipt of the license fee alone — no insurance proof is required of a journeyman. Each applicant must report any felony or misdemeanor conviction and provide a true-test copy from the clerk of the court; concealment or non-disclosure may be treated more severely than the underlying conviction itself.

Fees, renewal, and the life of the license

The money divides by payee, and this guide never adds the two sides together. To the testing service: the examination fee of $150, paid with the application, under the regulation’s direction that an applicant pay the fee directly to the testing service the Board has chosen, at the fee that service establishes; the same fee is paid again for every retake, and examination fees are nonrefundable. To the Board: the journeyman license fee of $25, original and renewal alike, under COMAR 09.15.01.03B as of January 1, 2025; Board fees are set by regulation under a statute that itself contains no dollar amounts, and all Board fees are nonrefundable. Two superseded schedules circulate — a repealed statutory schedule still displayed on a state portal, and the regulatory schedule that preceded the current one — and neither is used here. Inactive status carries its own smaller scheduled fee, and mid-cycle reactivation from inactive status costs the full license fee for the former category.

The renewal calendar is Maryland’s own: unless renewed for a two-year term, a license expires on the first October 1 that comes after its effective date and in an odd-numbered year. Renewal requires entitlement, the renewal fee, the insurance proof the statute names — which operates for a journeyman through the employing contractor-tier licensee, since a journeyman working under such a licensee’s control and supervision need not hold separate contractor insurance — and the Board’s renewal application. No implementing schedule for the statute’s staggered-expiration authorization appears in the regulations, so the October-first odd-year rule is the rule stated here. Continuing education is the guide’s clearest negative: the statute’s renewal conditions list no education and the regulations impose none, for the journeyman or any other class; the sole education duty in the title binds inspectors to an annual Board course. Any vendor figure for journeyman education hours, any annual-renewal claim, and any additional license class are fabricated against the statute’s exhaustive six-class list.

Inactive status is available at renewal to a valid licensee: no services while inactive, renewal on fee and application without insurance proof, and return only on the full renewal requirements. Restoration after expiration is available on application within four years, on the required fees; beyond four years, the Board may require the initial-application process as if the applicant had never been licensed. A license is not transferable, with a narrow wind-up exception for a deceased contractor’s personal representative. Retakes run on one consistent rule across all three layers: no more often than every thirty days, with a new application and a new fee; misbehavior at a sitting bars reexamination for at least one year. A longer interval for repeat attempts appears on a single Department page and in no statute, regulation, or bulletin text; it is unsupported and is not part of the rule stated here. Reciprocity is statutory, conditional, and short: examination may be waived only for an equivalently licensed journeyman in good standing whose state waives Maryland licensees similarly, and the agreements the Board actually publishes are with Delaware and Virginia. Federal refrigerant-handling certification stands outside the system: nothing in the statute, regulations, Department pages, or bulletin makes it a condition of a Maryland HVACR license.

A study plan built on the published outline

Maryland publishes its outline, so this plan spends its hours where the bulletin spends its questions. First, refrigeration and air conditioning, the twenty-five-question topic, from the textbook’s theory through sizing, components, and the operation-troubleshooting-maintenance arc. Second, electrical knowledge and heating systems together — forty questions between them — anchored in the 2018 mechanical code. Third, piping and air distribution, with Ductulator drills until duct sizing is performed at sitting speed. Fourth, safety as its own short block, drawn from the construction-safety regulation. Throughout, practice open-book under the real rules: only the five references, indexed and highlighted, tabbed with permanent tabs only, timed at the sitting’s pace, with every code answer checked against the 2018 edition. Finally, prepare the application as carefully as the material — documentation assembled, the gate measured against the statute, and the fee ready with the application.

The errors this examination is built to catch

Maryland’s sitting and its licensing system together catch a characteristic set of errors. Planning on the bulletin’s shorter gate strands an applicant who arrives short of the statute’s requirement. Studying the wrong code edition — answering from the 2021 field pointer, or from a combined code set the list never contained — fails items the 2018 text answers plainly. Bringing a non-compliant book — written-in margins, inserted papers, removable flag tabs, an unlisted fuel-gas volume — converts preparation into an exam-day violation. Underweighting electrical work and safety ignores a large share of the outline. Assuming renewal works like other states’ — annual dates, education hours — misreads a biennial October calendar with no education requirement at all. And contracting independently on an unrestricted scope mistakes the one limit the statute states in the credential’s definition itself.

Maryland in one view

Maryland in one view is a published examination inside a statute-governed license, and the candidate’s task is to keep each fact in the document that owns it. The bulletin owns the sitting — a hundred questions, four hours, six topics shared with the master examination, five references, one code edition. The statute owns the credential — six classes, a four-year and six-thousand-hour gate, a two-year October calendar, Delaware and Virginia as the whole of reciprocity, and no education hours anywhere. The regulation owns the fees and the fuses — twenty-five dollars to the Board, a year to claim a passed result, four years to restore an expired license. Almost every error available here is a layer error: a gate read from a bulletin paragraph, an edition read from a field pointer, a fee read from a repealed schedule.

Frequently asked questions

Why does this guide state a different eligibility gate from the examination bulletin’s journeyman paragraph?

Because the bulletin’s paragraph transposes the gate of the journeyman restricted license into the journeyman section. The statute requires at least four years holding an apprentice license with at least 6,000 hours of training under a licensed contractor; the Board’s regulation and the Department’s licensing pages agree with the statute, and the statute governs.

Is the journeyman examination really the same outline as the master examination?

Yes — the bulletin states the same six-topic distribution for both examinations: Electrical Knowledge, Motors, and Controls 20; Piping 15; Refrigeration and Air Conditioning 25; Heating Systems 20; Air Distribution Systems 15; Safety 5.

Does the examination include a practical component?

No practical, hands-on, or drawing component is stated for this examination in any source pulled; the sourced examination is the computer-administered, open-book sitting this guide describes.

When does enrollment open for the PassProfessor program?

The program is in the works and enrollment is not yet open. Leave an email address on this page to be notified when it is ready.