Washington’s 06B certificate — formally the HVAC/refrigeration – Restricted certificate (06B) — is a specialty electrician certificate of competency issued by the Washington Department of Labor and Industries (L&I) under RCW 19.28 and WAC 296-46B, bounded by a primary-connection ceiling of 250 volts single phase or 120 amps and examined by PSI in two sections that must each be passed. The PassProfessor Washington 06B HVAC/R Restricted Specialty program prepares candidates for that examination and for the boundary judgement the certificate demands in the field. This guide is the companion to the Washington 06B HVAC/R Restricted Specialty program page.
This program is part of the expanding PassProfessor catalog — join the notify list and we’ll email you when enrollment opens.
The credential at a glance
| Item | Verified position |
|---|---|
| Program | Washington 06B HVAC/R Restricted Specialty: the HVAC/refrigeration – Restricted certificate (06B) |
| Regulator | Washington Department of Labor and Industries (L&I), Electrical Program, under RCW 19.28 and WAC 296-46B |
| Examination vendor | PSI Services LLC, under contract to L&I; L&I approval and an Exam Unique ID required before scheduling |
| Examination structure | NEC & Theory — 34 questions, 2 hours; Washington Code — 20 questions, 1 hour; 54 questions, 3 hours, plus 10 unscored experimental questions |
| Passing standard | Each section independently — verbatim forms in the section below |
| Book policy | Open book, under the bulletin’s material rules |
| Tested code layer | 2020 National Electrical Code, plus the current RCW 19.28 and WAC 296-46B |
| Adopted field layers | 2023 National Electrical Code; field mechanical code: 2021 International Mechanical Code with Washington amendments — neither is the tested layer |
| Experience gates | 1,000 hours for examination eligibility; 2,000 hours for certification; 24 hours of basic classroom instruction |
| Credential term | Three-year renewal cycle; 24 hours of continuing education per cycle (8 / 4 / 12) |
| Administrator note | PassProfessor is independent and is not affiliated with the Washington Department of Labor and Industries |
Most exam guides begin with breadth and arrive at limits late. This one inverts the order, because the 06B inverts it in law: the scope rule is a permission inside a boundary — a power-connection ceiling, an occupancy fence for low-voltage work, and two prohibitions binding this certificate alone. The examination tests the boundary as heavily as the permission. The guide therefore works boundary-first: the ceiling and fence in full, then the examination, then the two-step hours mechanism.
First, the structure: a restricted specialty inside the electrical family
The 06B lives in the same architecture as every Washington electrician certificate. The statute is RCW 19.28, Electricians. The rule is WAC 296-46B: section 920 lists certificate types and scopes, section 945 governs qualifying for examinations, section 960 governs examinations, section 909 sets fees, and section 970 frames continuing and classroom education. L&I administers the family and states its entry principle plainly: to work in the electrical construction trade in Washington, you must have a valid electrician certificate issued by L&I. The 06B is catalogued among the 2,000-hour specialties, reflecting its certification figure.
No Washington HVAC contractor license appears in that architecture, and no mechanical license of that kind appears there either. The verified negative prints as structure throughout this guide: the 06B is not a contractor credential in miniature and not authority for mechanical work in itself. It certifies an individual specialty electrician whose work is performed in HVAC and refrigeration systems, inside the restriction the rule writes for it.
The family ladder frames the restriction. Below the certificate, the trainee certificate is the entry instrument. Beside it sits the 06A full specialty, whose scope sentence removes any voltage, phase or amperage limit inside the specialty. Above both sits the general journey level (01) certificate. One credit provision connects the rungs: 06B certification hours count toward the 06A figure, and toward nothing beyond it.
The boundary in full: WAC 296-46B-920(2)(f)(iv) read clause by clause
The ceiling sentence
The restriction’s core is a single prohibition. The (06B) HVAC/refrigeration specialty may not perform any electrical work where the primary electrical power connection to the HVAC/refrigeration system exceeds: 250 volts, single phase, or 120 amps — or where the work is otherwise barred by the same subsection.
Three reading disciplines follow. First, the measured point is the primary electrical power connection to the system — not an internal circuit, a control voltage or a component rating inside the equipment. Placement judgement begins at the connection, before anything downstream of it. Second, the limits are disjunctive: exceeding either figure places the work outside the certificate — within the voltage figure but above the amperage figure is outside, and the reverse is outside. Third, the phase term is part of the limit: the ceiling is written for single-phase connections, with no corresponding permission stated for multiphase connections above these terms.
What the rule does not do is equally instructive. It states no tonnage ceiling, no system capacity figure, no equipment-class list and no general occupancy ceiling for the certificate’s line-voltage work. Material that restricts this certificate by tonnage or equipment type imports a limit Washington did not write. The measurement that decides the question is the primary connection: its voltage, its phase and its amperage.
The low-voltage fence and its three stories
Class 2 low-voltage control wiring follows a separate, occupancy-based fence. In all residential occupancies, the 06B may perform the Class 2 low-voltage control circuit wiring and components work the rule lists. In occupancies other than residential, the permission holds only where the occupancy has no more than three stories on or above grade. The count is of the occupancy’s stories on or above grade, and the fence applies to the low-voltage permission specifically; it is not a general building-size limit on the certificate’s in-equipment work under the ceiling.
The sibling comparison sharpens the point: the 06A’s low-voltage permissions include Class 2 wiring in all occupancies regardless of stories. The restricted fence is a real narrowing, located in a specific permission — exactly the kind of conditional difference the Washington Code section examines.
The permissions inside the boundary
Inside the ceiling and the fence, the rule grants the in-equipment permissions in wording parallel to its sibling’s: line voltage components within the equipment, including product-illumination luminaires inside refrigeration cases and factory-authorised accessories; internal components of the equipment disconnecting means or controller, if not located in a motor control centre or panelboard; short sections of raceway for physical protection of low-voltage cables; and supply whips not over six feet. Replacements must be like-in-kind or the manufacturer’s authorised replacement.
The practical shape follows: the restricted holder’s working centre is the equipment itself — its internal components, disconnect and controller internals, short protective raceway sections and supply whip — plus the control wiring the fence permits. The certificate is narrow at the connection and at the building, and competent at the machine.
The shared prohibitions
A set of prohibitions binds both specialties, and the restricted certificate carries them in full. It may not install line voltage controllers or disconnect switches external to the equipment, apart from the narrow exception: a like-in-kind surface-mounted disconnect enclosure rated not more than 20 amperes and 120 volts, with up to ten feet of protective raceway, not terminating in a panelboard. It may not install integrated building control systems other than HVAC and refrigeration systems; stand-alone line voltage equipment — heat cable, wall and baseboard heaters, contactors and motor starters are the rule’s examples — unless exclusively controlled by and integrally connected to the system; building-lighting luminaires; raceway or conduit systems; panelboards, switchboards or motor control centres external to the system; or line voltage service, feeder or branch circuit conductors, apart from the narrow supplementary-device exception.
The two bars that bind 06B alone
Two prohibitions in the restricted subsection have no counterpart in the full specialty’s list. First, the allowed telecommunications and low-voltage wiring is barred to this certificate when it runs in a conduit or raceway system — a method-based bar that placement judgement must check after the occupancy fence, not instead of it. Second, the classified-location bar is total: no wiring in NEC Articles 500 through 516 classified locations. The full specialty’s bar reaches only classified-location wiring outside the equipment. A restricted candidate who memorises the sibling’s version of this bar has memorised a permission this certificate does not hold.
The passing standard, verbatim
Washington publishes the standard twice, and the guide states it only in the published forms.
The PSI bulletin, in its Score Reporting section, states: “You must score 70% to pass.”
The L&I Electrical Examination page states: “You must pass each section of the examination with a score of 70% or greater.”
Each section must independently reach the standard. There is no combined score across the 54 questions and no averaging between the 34-question section and the 20-question section. For this certificate the point deserves emphasis, because the sections are asymmetric in a way that tempts a blended reading: the smaller section is the one that examines the boundary, and it holds full veto power over the result. Readiness is two verdicts, tracked separately, or it is not readiness at all.
The examination in full
Approval before scheduling
Candidates must be approved by L&I before scheduling; L&I sends an eligibility notice carrying an Exam Unique ID used to register with PSI. The examination is computer-administered at PSI centres, and the score appears on screen immediately. For 06B candidates, approval is sought from the examination-eligibility position at 1,000 hours, not the certification position at 2,000.
Section one: NEC & Theory — 34 questions, 2 hours
The bulletin outline for 06B-HVAC/R Restricted, Electrician column, distributes the 34 questions across knowledge areas, noting that the number in any individual area is approximate. The largest area is General Trade Knowledge & Theory, at 6 questions; wiring methods under NEC Articles 300 through 398 and the area spanning NEC Articles 430 through 450 — motors, HVAC, generators and transformers — carry 5 each.
The section is a reduced form of the family’s code-and-theory paper — the full specialty’s corresponding section carries 50 questions — but it is not diluted in kind. Theory questions remain general, drawn from general copyrighted electrical publications, and may include general mathematics and theory computation, all keyed to the tested 2020 NEC. A candidate preparing only at the level of equipment familiarity is exposed in the section’s largest area. The outline’s Administrator and Master Electrician columns belong to different certificates; only the Electrician column describes this examination, and the full specialty’s weightings are not this paper.
Section two: Washington Code — 20 questions, 1 hour
The Washington Code section matches the full specialty’s in size: 20 questions, 1 hour, examining the current Chapter 19.28 RCW and Chapter 296-46B WAC. The bulletin states the basis: all law, rule and code questions are based on the current RCW 19.28 and WAC 296-46B, and the 2020 National Electrical Code.
For the restricted candidate, this section is the examination’s centre of consequence. Its material includes the certificate’s own scope subsection — ceiling, fence, permissions, shared prohibitions and the two restricted-only bars — together with the qualifying-hours structure, supervision positions, examination procedure, fees and renewal education. Three minutes per question, in material decided by precise rule boundaries, rewards drilled placement: given a described system, connection, occupancy and method, state whether this certificate may perform the work, and name the deciding clause.
Experimental questions
In addition to the scored questions, 10 experimental questions may be administered. They will not be scored, and the time taken to answer them will not count against examination time. They are unmarked in the sitting: full care on every item, because the candidate cannot identify which items are experimental.
Open book, precisely
All examinations in this program are open book. The bulletin states: “All examinations are open book,” and permits any original copyrighted material with a silent, nonprinting, nonprogrammable calculator. L&I’s bring-list specifies the 2020 NEC book, printed Chapter 19.28 RCW and Chapter 296-46B WAC in a three-ring binder, and any original copyrighted material — examples include Ugly’s, Ferm’s Fast Finder and Soares Grounding.
Permanent index tabs, highlighting and underlining are allowed; handwritten notes and removable or sticky tabs are not, and materials with unacceptable notations may be confiscated. For this certificate, the binder deserves the greater share of preparation attention: the scope subsection and the qualifying section must be retrievable in seconds, in exact wording, because the boundary questions turn on wording — a voltage figure, a phase term, a story count, a method — that paraphrase reliably blurs.
Results, the one-year window and retakes
The score appears on screen immediately. A candidate has one year from the exam approval letter date to pass all sections; passed sections carry only within that period; and the first attempt must consist of all sections. At least 14 days must pass between attempts. After failing any section three times within a one-year period, 90 days — three months in the bulletin’s wording — must pass between further attempts. Results may be challenged in writing to the Chief Electrical Inspector within 20 days, under WAC 296-46B-960. The examination as published consists of the two computer-administered sections; no other component is stated for it.
The retake structure meets the hours structure at one point: a candidate who passes steps into the modified-trainee position described below, while a candidate who has not yet passed remains under 100 percent supervision. Retake timing is therefore also supervision planning.
The two-step hours rule: 1,000 to sit, 2,000 to certify
WAC 296-46B-945, Table 945-1, gives the restricted row two figures, and this guide prints them distinctly wherever either appears: 1,000 hours minimum work experience required to be eligible for examination, and 2,000 hours required for certification. Any single-figure statement of this certificate’s hours requirement is wrong against the rule’s table — including a flat statement that 2,000 hours are required before the examination, which would postpone a sitting the rule makes available a thousand hours earlier.
The mechanism between the figures is the modified-trainee structure in the table’s notes. Until the examination is passed, the trainee works under 100 percent supervision — L&I’s summary for 2,000-hour specialties states the same position. Once it is passed, the modified trainee — holding the 0 percent supervision certificate — may work unsupervised while completing the balance of the 2,000 hours. That certificate is valid for no more than two years, and only one may be held in a specialty; if the hours are not completed in time, the trainee moves to a 75 percent supervision certificate until they are.
The gates around the hours are the family’s standard gates, at this specialty’s band: a current electrical training certificate; an employer employing an appropriate certified electrician; 24 hours of basic classroom instruction — the figure where 2,000 or more but less than 4,000 hours is required; age at least 16; and no more than 50 percent of the minimum experience from a training school program. An appropriate two-year registered apprenticeship route is also provided.
The route in order runs: earn hours under 100 percent supervision with the training certificate held and the 24 classroom hours completed; at 1,000 hours, obtain L&I approval and sit both sections; on passing, complete the balance of the 2,000 hours unsupervised as a modified trainee, within that certificate’s two-year validity; and receive certification at 2,000 hours. The credit provision then supplies the forward path: the 2,000 certification hours may be credited toward the 4,000 hours required for 06A certification, and cannot be credited toward the general journey level (01) examination. The credit runs to the full specialty and stops there.
Three code layers, never merged
The tested layer is the 2020 National Electrical Code, plus the current RCW 19.28 and WAC 296-46B. Every examination answer is keyed to that layer.
The adopted electrical layer is the 2023 edition of the National Electrical Code, adopted by WAC 296-46B-010 effective April 1, 2024 — with the same provision already stating that, effective December 31, 2026, the 2026 edition is adopted and replaces the 2023 edition. Field installations are inspected against the adopted layer; the examination tests the 2020 edition. Neither statement may borrow the other’s edition.
The field mechanical layer is the 2021 International Mechanical Code with Washington amendments, adopted at Chapter 51-52 WAC effective March 15, 2024 — field context only, not an examination reference for this NEC examination. Renewal repeats the discipline: code-update hours follow the adopted code, not the tested one.
Fees, by instrument
PSI — the examination instrument. PSI charges per hour: one hour $45.00, two hours $55.00, three hours $65.00, four hours $75.00, five hours $85.00, six hours $95.00, seven hours $105.00. This examination totals three hours — the $65.00 row, not the four-hour row pricing the full specialty’s sitting. Registration fees are not refundable or transferable, and retests are billed per hour. L&I confirms that PSI fees are in addition to L&I application fees.
L&I — the state instrument. Under WAC 296-46B-909, in its current text effective July 1, 2026, the application — including the original certificate and processing — is $114.60, with $44.20 nonrefundable after submission. Renewal is $106.40 on paper or $92.60 fully online; late renewal is $212.90 or $185.30. The fee rule’s department-administered examination figure applies to examinations the department itself administers; PSI administers this one, so that figure is not this program’s fee.
Renewal and continuing education
The certificate renews on a three-year cycle, with 24 hours of continuing education in the cycle: 8 hours on currently adopted NEC changes, 4 hours on Chapter 19.28 RCW and related Chapter 296-46B WAC, and 12 hours in any other approved course. The same class may not be taken twice for credit. The requirement matches the full specialty’s exactly — the restriction narrows scope, not the obligation to stay current.
A study plan built on placement judgement
First, fix the route calendar. Confirm the two-step position honestly: hours documented toward 1,000 for the sitting, the 24 classroom hours in place, the training certificate current, and a plan for the balance to 2,000 inside the modified certificate’s two-year validity after a pass.
Second, drill the boundary as the primary skill. Build placement exercises from the rule’s own variables: connection voltage, phase and amperage; occupancy and story count; wiring method, including the conduit and raceway question; equipment-internal against equipment-external work; classified against unclassified locations. For each job, the answer has three parts — permitted or barred, the deciding clause, and the deciding figure. Exactness decides: the ceiling’s numbers must be recalled without approximation.
Third, build the NEC & Theory base at this paper’s weight. General trade knowledge, theory and computation first — the largest area — then wiring methods and the motors, HVAC, generators and transformers area, in the tested NEC 2020, practised with the permanently tabbed book that will enter the room.
Fourth, read the Washington material as a working text — types and scopes, qualifying and supervision, procedure, fees and renewal education — organised in the binder for retrieval at three minutes per question. Fifth, rehearse as Washington scores: timed practice in the real proportions, scored per section against the verbatim standard.
The errors this examination is built to catch
Flattening the hours. Assuming a single hours figure — above all, requiring 2,000 hours before the sitting — contradicts Table 945-1. Inventing a different ceiling. Tonnage and equipment-class limits do not appear in the scope rule; the ceiling is the primary connection at 250 volts single phase or 120 amps. Borrowing the sibling’s permissions. The 06A’s broader low-voltage reach and narrower classified-location bar belong to the 06A; this certificate’s total classified-location bar and conduit-and-raceway bar are its own. Borrowing the sibling’s paper. Fifty questions, four hours and the $75.00 row describe the full specialty’s sitting, not this one. Blending the sections. Each section must reach its standard alone. Studying the adopted code for the sitting. The examination tests NEC 2020; the adopted editions govern the field. Merging the fees. PSI’s $65.00 and L&I’s $114.60 are separate instruments.
Washington 06B in one view
The 06B is Washington’s restricted electrical specialty for HVAC and refrigeration work: a certificate whose identity is a boundary — a primary connection that must not exceed 250 volts single phase or 120 amps, a low-voltage permission fenced at three stories outside residential occupancies, and two prohibitions its sibling does not carry — wrapped around genuine in-equipment authority. It opens its examination at 1,000 hours and its certification at 2,000, joined by a trainee mechanism with a two-year clock. It is examined in 34 NEC & Theory questions and the family’s full 20-question Washington Code section, each required to reach the published standard alone, and renewed on the same three-year, 24-hour cycle as the full specialty. Candidates who hold the boundary exactly — in numbers, in clauses, in hours — are the candidates this examination is designed to pass. The companion Washington 06B HVAC/R Restricted Specialty program page carries the program overview.
Frequently asked questions
What is the 06B ceiling, exactly?
WAC 296-46B-920 bars the specialty from any electrical work where the primary electrical power connection to the system exceeds 250 volts, single phase, or 120 amps. Exceeding either figure places the work outside the certificate. The rule states no tonnage or equipment-class limit.
What is the three-story fence?
The Class 2 low-voltage permission covers all residential occupancies, and other occupancies only where they have no more than three stories on or above grade.
Which two bars bind 06B but not 06A?
The allowed telecommunications and low-voltage HVAC and refrigeration wiring when run in a conduit or raceway system, and any NEC Articles 500 through 516 classified-location work. The full specialty’s classified-location bar reaches only wiring outside the equipment.
What score passes, exactly?
In the bulletin’s words: “You must score 70% to pass.” In L&I’s words: “You must pass each section of the examination with a score of 70% or greater.” Each of the two sections must reach the standard independently.
How is the examination structured?
NEC & Theory — 34 questions, 2 hours — and Washington Code — 20 questions, 1 hour: 54 questions and 3 hours in total, open book, plus 10 unscored experimental questions.
When may I sit — at 1,000 hours or 2,000?
At 1,000 hours. Examination eligibility requires 1,000 hours; certification requires 2,000. After passing, the remaining hours are completed as a modified trainee at 0 percent supervision, under a certificate valid for no more than two years; before passing, supervision is 100 percent.
What classroom instruction is required?
24 hours of basic classroom instruction, with a current electrical training certificate. Applicants must be at least 16, and no more than half the minimum experience may come from a training school program.
Which NEC edition does the examination test?
The 2020 edition, with the current RCW 19.28 and WAC 296-46B. The adopted field edition is the 2023 NEC (2026 edition effective December 31, 2026); the 2021 International Mechanical Code layer is field context only.
What are the fees?
PSI charges $65.00 for the three-hour examination. L&I’s application is $114.60, with $44.20 nonrefundable after submission. Renewal is $106.40 on paper or $92.60 fully online; late renewal is $212.90 or $185.30. The instruments are separate.
Do the hours count toward the 06A?
Yes: the 2,000 certification hours may be credited toward the 4,000 hours required for 06A certification — but not toward the general journey level (01) examination.
When does enrollment open for the PassProfessor program?
The program is in the works; enrollment is not yet open. PassProfessor is an independent preparation provider, not affiliated with L&I or PSI. Leave an email address and PassProfessor will write when the program is ready — only about this program.