Texas registers its air conditioning and refrigeration technicians by requirement and certifies them by choice. The Certified Technician designation, issued by the Texas Department of Licensing and Regulation, is a voluntary certification earned by passing the TDLR competency examination delivered by PSI — 60 scored items in 112 minutes, plus 4 non-scored items in 8 minutes, open book — with the rule’s standard stated in one sentence: “A passing grade is 70%.” This guide follows the credential layer by layer: the registration floor beneath it, the examination, the eligibility routes, the fees by instrument, and the two sourced effects certification actually carries.
This program is part of the expanding PassProfessor catalog — join the notify list and we’ll email you when enrollment opens.
The credential at a glance
| Item | Verified position |
|---|---|
| Program | Texas Certified A/C Technician — a voluntary TDLR certification for individual technicians |
| Regulator | Texas Department of Licensing and Regulation (TDLR), under Texas Occupations Code Chapter 1302 and 16 TAC Chapter 75 |
| Mandatory floor beneath it | Registered Technician — registration required to assist a licensed ACR contractor in ACR maintenance or repair work; no examination |
| Examination vendor | PSI Services LLC — scheduling only after TDLR approves eligibility (Candidate Information Bulletin © 2026, updated July 9, 2026) |
| Examination | 60 scored items + 4 non-scored items / 112 minutes + 8 minutes / open book, computer-based |
| Passing standard | “A passing grade is 70%” — 16 TAC § 75.21(b), stated verbatim |
| Tested codes | Effective September 1, 2026: the 2024 International Fuel Gas Code, the 2024 International Mechanical Code, and the 2024 Uniform Mechanical Code |
| PSI examination fee | $60 (paid to PSI) |
| TDLR application fee | $50 (paid to TDLR) |
| Term and renewal | 1-year term; renewal fee $35; no continuing education requirement applies to technicians |
| Language | English and Spanish at no additional cost |
| Administrator note | PassProfessor is independent and is not affiliated with the Texas Department of Licensing and Regulation |
Texas runs three distinct instruments in this trade, and almost every misunderstanding about this credential comes from merging them. At the base sits the Registered Technician: a mandatory registration, obtained without an examination. Above it sits the Certified Technician: a voluntary certification, obtained by examination, that changes a technician’s title and standing without changing the tasks the technician may perform. Above both sits the ACR contractor credential: the only instrument that authorises contracting with the public, carrying endorsements, classes, insurance duties, and continuing education of its own. This guide is about the middle instrument; the contractor tier appears only as a boundary, and at the one point where the statute connects the two — the alternate route that credits this certification. The companion program page at /texas-certified-ac-technician-exam-prep/ carries the shorter account.
Reading the verified facts
Facts in this guide are kept in the layer that published them. Statute facts come from Texas Occupations Code Chapter 1302; rule facts from 16 TAC Chapter 75; examination facts from the PSI Candidate Information Bulletin for TDLR air conditioning and refrigeration examinations, © 2026, updated July 9, 2026; application facts — ages, routes, fees, the term — from TDLR’s technician pages. Where the record is silent, this guide says so and prints nothing in the silence’s place. The clearest instance is the examination’s content: no content outline for this examination exists in the sources, and this guide prints none, implies none, and borrows none from the contractor sittings.
The route, step by step
Step one — hold the floor. Confirm registration: any person assisting a licensed ACR contractor in ACR maintenance or repair work must be registered as a technician, registered or certified. Step two — check the age and the route. Certification requires an applicant of at least 18 years, qualifying by the experience route or the approved training route below. Step three — apply to TDLR, paying the $50 application fee, and complete every requirement within 1 year of filing. Step four — wait for eligibility approval. Scheduling with PSI opens only after TDLR approves eligibility. Step five — sit and pass the examination: 60 scored items in 112 minutes, plus 4 non-scored items in 8 minutes, open book, to the rule’s standard — “A passing grade is 70%.” Step six — hold and renew on a 1-year term at a $35 renewal fee, with no continuing education requirement. There is no step at which certification widens the work itself.
The registration floor, in depth
The mandate is one sentence: any person who assists a licensed ACR contractor in performing ACR maintenance or repair work must register as a technician (registered or certified) (§ 1302.501(a)). The Registered Technician position built on that mandate is deliberately light: an applicant at least 16 years old, an application fee of $20, and — in TDLR’s stated position — no practical experience and no examination. Registration runs 1 year, renewed at $20.
That lightness is the point of the design. Texas chose to police the floor by registration — knowing who is doing the assisting work, and under whose supervision — rather than by examination; the examination enters the system only where a technician volunteers for it. A certification candidate should therefore be able to state the floor exactly. Confusing its figures with the certification’s — the $20 registration fee with the $50 application fee, the age of 16 with the age of 18 — is the most ordinary error available in this credential, and the guide keeps the two sets apart throughout.
Supervision, advertising, and technician duties
Every technician, registered or certified, works under the supervision of a licensed ACR contractor and may not advertise air conditioning and refrigeration services (§ 1302.503). A company may use only licensed contractors, registered technicians, certified technicians, or qualifying students to perform maintenance work. Where a technician younger than 18 acts on a contractor’s behalf, the contractor must provide in-person supervision, directly or through a certified technician, at all times. That provision assigns the certified technician one distinct working function — standing as the in-person supervisor of a younger technician — stated here exactly at that size, as a supervision provision, not as a widening of the certified technician’s own task scope.
The technician duties at § 75.73 complete the picture: assure the mechanical integrity of the work performed; no misrepresentation; no non-exempt maintenance work knowingly performed without a licensed contractor’s supervision; no work knowingly performed for a company with no affiliated supervising contractor; no letting another person, or a non-employer company, use the registration or certificate. Altering a registration or certificate is prohibited, and a change of mailing address or telephone number must be reported to TDLR in writing within 30 calendar days. None of these duties changes on certification.
What certification adds — the two sourced effects, and the limit on both
First effect: the protected title. Only persons holding the designation may call themselves “certified technicians” (§ 1302.5055(b)), and a technician must not use the designation unless certified. In a trade where customers and employers cannot inspect competence directly, the title is a state-policed signal, usable only by those who volunteered for the examination and passed it.
Second effect: the contractor alternate route. Under § 1302.255(a)(2)(B), contractor eligibility may be met through technician certification held for the preceding 12 months together with at least 36 months of practical experience under a licensed ACR contractor in the preceding 48 months. For comparison, stated as a contractor-layer fact only, the standard contractor route requires 48 months of practical experience in the preceding 72 months (§ 1302.255(a)(2)(A)). The alternate route is the certification’s measurable career value — printed here as a contractor-eligibility provision that credits certification, never as a requirement a certification applicant must meet.
The limit, stated plainly. Against those two effects stands the same-tasks rule: a registered technician “is not required to be certified, and may perform the same tasks as a certified technician” (16 TAC § 75.73(f)). Certification confers no broader task scope — the same tasks, under the same contractor supervision, under the same advertising bar, bound by the same § 75.73 duties. Any account implying certified technicians may perform work registered technicians may not is contradicted by the rule’s own text. The honest summary is narrower and, for the right candidate, sufficient: certification proves examined competence, carries a protected title, and counts toward the contractor tier, while the work itself stays exactly as wide as registration already made it.
Structure that does not exist. The certification has no endorsements and no classes. Endorsements — environmental air conditioning, and commercial refrigeration and process cooling or heating — attach to the contractor credential alone (§ 1302.254(a)), and the license-number codes and Classes A and B sit at the contractor layer (§ 75.22(b)). No class, endorsement, specialty, or endorsement code for a Certified or Registered Technician appears anywhere in the Texas fact record. Material that sorts Texas air conditioning credentials by endorsement and class is describing the contractor tier.
The sitting itself
The examination is delivered by PSI Services LLC under TDLR’s contract, and a candidate may schedule only after TDLR approves eligibility, on the eligibility email or postcard from PSI. It is computer-based and open book: only references on the PSI Examination Reference Material List are allowed in the room, and candidates must bring their own. Materials may be highlighted, underlined, and noted before the session, and tabbed with permanent index tabs only; candidates may not write, highlight, or mark references during the session, and no temporary tabs or loose paper are permitted. A sitting of this design examines retrieval as much as recall — the candidate who has organised the references beforehand holds a real advantage over the candidate who merely owns them.
On the day: arrive 30 minutes early; present one valid government-issued photo identification matching the TDLR eligibility record; the only permitted calculators are non-programmable, silent, battery-operated models without paper-tape printing or an alphabet keyboard. The score is shown on screen immediately, an official score report is printed at the site, and a candidate who does not pass receives a diagnostic report by subject area. Cancelling or rescheduling without forfeiting the fee requires notice 2 days before the scheduled date; late arrival, a missed sitting, a late cancellation, or lack of proper identification forfeits the fee.
The examination is available in English and Spanish at no additional cost, and a bound word-to-word translation dictionary — no pictures, no definitions — may be brought. Retakes are unusually permissive: a candidate who does not pass may schedule a retake with PSI within 24 to 48 hours, and may retake without limit through the eligibility period — until the application expires, 1 year from submission. After expiration, a fresh application is required. Cheating is grounds for denial, suspension, or revocation and for an administrative penalty (§ 75.21(d)). No practical, hands-on, or drawing component is stated in the sources retrieved, and this guide claims none in either direction.
References without an outline
Preparation needs an honest map of what the sitting draws on, and the record supplies references rather than weights. The tested-edition banner, quoted below, keys the examinations to the 2024 International Fuel Gas Code, the 2024 International Mechanical Code, and the 2024 Uniform Mechanical Code. The bulletin’s business and law references are the Texas ACR License Law (Occupations Code Chapter 1302), the Texas ACR License Rules (16 TAC Chapter 75), and OSHA 29 CFR Part 1904. The technical reference named for this examination is **Modern Refrigeration and Air Conditioning, 22nd edition, 2025, with the ADI Duct Size Calculator**.
What the record does not supply matters as much. It publishes no subject-area outline and no topic weights for this examination. The only outline cells it records anywhere nearby belong to the contractor environmental examinations — contractor material, describing different sittings for a different credential, barred from this guide. References the bulletin states additionally for those contractor examinations are likewise not reassigned here. A programme that printed a percentage breakdown for this examination would be inventing it, and a candidate who memorised one would be pacing study time by numbers TDLR and PSI never published for this sitting. The defensible posture is the one this guide takes: cover the verified frame whole — the three tested code editions, the law and the rules, the named technical reference — and treat any imported weight as a defect in the source offering it.
Three code layers, kept apart
The tested layer. The PSI bulletin banner states it verbatim: “Effective September 1, 2026, the examinations will be referenced to the 2024 International Fuel Gas Code, the 2024 International Mechanical Code, and the 2024 Uniform Mechanical Code.” The bulletin body’s earlier listings of the 2021 editions are superseded for examinations on or after that date.
The adopted layer. Rule § 75.110, as amended, adopts the 2024 editions of the International Residential Code, the International Mechanical Code, the International Fuel Gas Code, and the Uniform Mechanical Code effective September 1, 2026; the pre-amendment rule adopted the 2021 editions of the same four codes. Note the discipline the layers demand: the adopted layer names four codes, the tested banner names three. Whether the 2024 International Residential Code is an allowed examination-room reference is not stated in the bulletin sections retrieved, and this guide states no examination-room claim for it. Adopted is not the same proposition as tested, even when — as here, after the September 2026 alignment — the editions coincide.
The municipal layer. The practice standard in a municipality is the code the municipality adopted by ordinance, consistent with the Act and Chapter 75; where no code has been adopted, the rule’s defaults apply. Daily work sits in this layer; the sitting sits in the tested layer; preparation should hold all three apart.
Eligibility, in depth
The age gate is 18 years, distinct from the registration floor of 16. An applicant who is 16 or 17 may register and work as a Registered Technician, but may not yet hold this certification.
The experience route requires 24 months of air conditioning and refrigeration related work under the supervision of a licensed ACR contractor, verified on a form completed by the supervising contractor — not by the applicant. That verification discipline is part of the route’s substance: the experience is attested by the contractor who supervised it, and an applicant should secure that attestation as the work accrues rather than reconstruct it at filing.
The training route requires completion of a department-approved certification training program of 2,000 hours of combined instruction and practical experience — the Chapter 75 definition sets the same 2,000-hour floor — with application materials received within 48 months of completing the program. The window makes this route time-sensitive in a way the experience route is not.
Military experience may be combined with, or used as part of, the experience requirement, supported by the Military Supplemental Application. No hour-for-hour conversion figure is stated in the sources, and this guide prints none.
Two closing conditions bind every route: the applicant must pass the TDLR competency examination, having first satisfied the eligibility requirements as of the filing date, and all requirements must be completed within 1 year of filing. The one-year fuse and the unlimited-retake window are the same period viewed from two sides — a candidate may sit repeatedly within it, but the file closes when it ends.
Fees, term, renewal — and the education requirement that is not there
Each dollar in this credential belongs to a named instrument, and this guide never merges them. The TDLR application fee is $50, non-refundable, paid to the department. The PSI examination fee is $60, paid to PSI at scheduling. No combined total is published anywhere in this package. Candidates comparing this credential’s costs with the contractor tier’s will find different figures at every layer, because the instruments are different.
The certification is valid for 1 year from the date of issue, and the renewal fee is $35. Late renewal follows the published ACR schedule: expired 90 days or less, 1.5 times the renewal fee; more than 90 days but less than 18 months, 2 times; at least 18 months but less than 3 years, 2 times, only with executive director approval. TDLR advises beginning renewal 30 to 60 days before expiration.
Renewal requires no continuing education — and the negative deserves its own paragraph, because contractor material routinely suggests otherwise. The continuing education rule at § 75.25 imposes its requirement, by its terms, only to renew a contractor credential; TDLR’s technician renewal position lists only the renewal application and the fee. The record therefore supports the negative as stated: no continuing education requirement applies to Registered or Certified Technicians, and completing contractor-tier education hours is not a condition of holding this certification.
A short history that still traps candidates
The former § 75.28 legacy certified-technician designation was repealed effective September 1, 2026. It is recorded here for one reason only: older material still in circulation describes it, and a candidate working from that material could mistake a repealed legacy provision for a live route. It is not one. The current certification rests on the provisions cited throughout this guide — the protected title at § 1302.5055, the application and examination framework, the same-tasks rule at § 75.73(f) — and never on § 75.28.
The errors this examination is built to catch
Calling the certification compulsory. It is voluntary; registration is the mandate. Calling it a contractor credential. It satisfies no part of the contracting bar at § 1302.251(a). Claiming wider work. Section 75.73(f) gives registered and certified technicians the same tasks. Importing contractor structure — endorsements, classes, insurance duties, continuing education — into a technician credential that carries none of them. Importing contractor numbers — another sitting’s counts, minutes, or fees — into this examination’s published split of 60 scored plus 4 non-scored items in 112 plus 8 minutes at a $60 PSI fee. Studying to an invented outline. No outline for this examination exists in the sources. Blending the ages and fees of registration and certification. Resting on the repealed legacy designation. Each error is corrected by returning to the layer that actually governs the proposition.
Federal EPA Section 608 technician certification belongs here as a boundary rather than an error: it is a separate federal credential and a separate PassProfessor program, and no provision of Chapter 1302, no passage of Chapter 75, and no TDLR technician page retrieved makes it a condition of this Texas certification.
A study plan built on the verified frame
First, the regime map. Registration mandate, supervision, advertising bar, § 75.73 duties, the same-tasks rule, the protected title, the alternate route — the short set of Texas positions that define this credential, learned at rule level. Second, the tested codes. The 2024 International Mechanical Code, International Fuel Gas Code, and Uniform Mechanical Code, worked as open-book retrieval: know where provisions live, tab within the bulletin’s rules, and practise finding answers under the clock. Third, the law and rules references — Chapter 1302 and Chapter 75, with OSHA 29 CFR Part 1904 in its referenced place. Fourth, the technical reference — Modern Refrigeration and Air Conditioning, 22nd edition, 2025, and the ADI Duct Size Calculator — brought by the candidate, organised beforehand. Fifth, timed sittings in the published shape — scored work paced against 112 minutes — with every miss sorted by kind: a fact not yet learned, a provision not found fast enough, a Texas position confused with another tier’s. Because no outline weights exist, no stage of this plan rations attention by percentage; the frame is covered whole.
After the sitting: holding a voluntary credential well
Certification runs on its 1-year term, renewed at $35 with no continuing education to log. The working duties never pause between renewals: contractor supervision, the advertising bar, the § 75.73 duties, the 30-day written notice of an address or telephone change. For the technician aiming at the contractor tier, the calendar matters from the date of issue: the alternate route at § 1302.255(a)(2)(B) counts certification held for the preceding 12 months, so the holding period itself is part of the qualification being built. For the technician staying at this tier, the credential’s value is the title itself — held only by those who met the standard the rule states in five words: “A passing grade is 70%.”
Frequently asked questions
Does Texas require technicians to be certified?
No. Certification is voluntary. Registration is mandatory for any person who assists a licensed ACR contractor in ACR maintenance or repair work (§ 1302.501(a)).
What is the difference between a Registered Technician and a Certified Technician?
Registration is the mandatory floor: age 16, a $20 fee, a 1-year term, no experience or examination required. Certification is the voluntary step above it: age 18, an eligibility route, a passed examination, a $50 application fee, a $35 renewal. Under § 75.73(f), both may perform the same tasks.
What does certification actually give the holder?
Two sourced effects: the protected “certified technician” title (§ 1302.5055(b)), which only holders may use, and the contractor alternate route at § 1302.255(a)(2)(B).
Does certification let a technician do more kinds of work?
No. Section 75.73(f) states that a registered technician is not required to be certified and may perform the same tasks as a certified technician. Certification confers no broader task scope, and supervision and advertising limits apply to both.
How is the examination structured?
60 scored items plus 4 non-scored items, in 112 minutes plus 8 minutes, open book and computer-based through PSI, scheduled after TDLR approval.
What score passes?
The rule states it verbatim: “A passing grade is 70%” (§ 75.21(b)).
Is there a content outline with topic weights for this examination?
No. None exists in the sources, and this guide prints and implies none. Outline figures for Texas contractor examinations are contractor material for different sittings.
Which code editions does the examination test?
Effective September 1, 2026, the 2024 International Fuel Gas Code, the 2024 International Mechanical Code, and the 2024 Uniform Mechanical Code, per the PSI bulletin banner. Earlier 2021 listings are superseded.
What are the eligibility routes?
Age 18, plus either 24 months of ACR-related work under a licensed ACR contractor, verified on a form completed by the supervising contractor, or a department-approved 2,000-hour certification training program with materials received within 48 months of completion. Military experience may count toward the experience requirement. All requirements, including passing the examination, must be completed within 1 year of filing.
What does the credential cost, instrument by instrument?
The TDLR application fee is $50 and the PSI examination fee is $60, paid to different parties under different instruments. Renewal is $35 per 1-year term. No combined total is published here, because the fees are not one charge.
Does a Certified Technician complete continuing education to renew?
No. No continuing education requirement applies to Registered or Certified Technicians; the § 75.25 requirement applies by its terms to contractor renewal only.
Can a certified technician advertise or work without a contractor?
No. Technicians must work under a licensed ACR contractor’s supervision and may not advertise ACR services (§ 1302.503).
What is the former § 75.28 legacy designation?
A repealed provision — repealed effective September 1, 2026. History only, never a current credential or route.
Is EPA Section 608 certification required for this Texas designation?
No source retrieved makes it a condition of this certification. EPA 608 is a separate federal credential.
Is PassProfessor affiliated with TDLR or PSI?
No. PassProfessor is an independent preparation provider. TDLR alone certifies and approves eligibility, and PSI delivers the examinations.
When does enrollment open for the PassProfessor program?
The program is in the works; enrollment is not yet open. Leave an email address and PassProfessor will write when it is ready.