Texas ACR Contractor — Commercial Refrigeration Class B Exam Guide: The Class Line Above the Work, the Loop Boundary Inside It

The Texas ACR Contractor — Commercial Refrigeration Class B license carries the combined Commercial Refrigeration and Process Cooling or Heating endorsement inside the Class B license-class limit — 25 tons and 1.5 million BTU/hour, per individual unit. Its PSI examination runs 100 scored items plus 5 non-scored items in 170 minutes plus 10 minutes, open book, referenced from September 1, 2026 to the 2024 mechanical, fuel gas, and uniform mechanical codes — and the rule states the standard in one sentence: “A passing grade is 70%.” This guide works through the limit’s correct attribution, the endorsement’s process boundaries, the full contractor gate, and the sitting.

This program is part of the expanding PassProfessor catalog — join the notify list and we’ll email you when enrollment opens.

The credential at a glance

ItemVerified position
ProgramTexas ACR Contractor — Commercial Refrigeration Class B
Endorsement (full statutory name)Commercial Refrigeration and Process Cooling or Heating — a single combined endorsement, code R (C = Combined with environmental)
RegulatorTexas Department of Licensing and Regulation (TDLR), under Texas Occupations Code Chapter 1302 and 16 TAC Chapter 75
ScopeClass B license-class limit — cooling 25 tons and under, heating 1.5 million BTU/hour and under, per individual unit (§ 1302.253; § 75.22(c))
VendorPSI Services LLC, scheduling only after TDLR approves eligibility; Candidate Information Bulletin © 2026, updated July 9, 2026
Examination100 scored items + 5 non-scored items / 170 minutes + 10 minutes / open book, computer-based
Passing standard“A passing grade is 70%” — 16 TAC § 75.21(b), verbatim
Tested editionsEffective September 1, 2026: 2024 International Fuel Gas Code, 2024 International Mechanical Code, 2024 Uniform Mechanical Code
Fees, by layerTDLR application $115. PSI examination $60. Renewal $65 per 1-year term, late at the published multipliers
Insurance (Class B)$100,000 per occurrence / $200,000 aggregate / $100,000 products and completed operations aggregate
Continuing education8 hours per renewal, including 1 hour of Texas law and rules
Administrator notePassProfessor is independent and is not affiliated with the Texas Department of Licensing and Regulation

The companion program page is at /texas-acr-contractor-commercial-refrigeration-class-b-exam-prep/. This guide is the deeper document: it separates what this credential most often has merged for it — the license-class limit from a fictitious refrigeration limit, the endorsement’s two halves from a fictitious pair of licenses, scored items from non-scored items, tested codes from applicable codes from municipal codes, and each dollar layer from the others.

The limit, attributed correctly

A Class B license is limited to cooling systems of 25 tons and under and heating systems of 1.5 million BTU/hour and under (§ 1302.253). Three readings of that sentence must be held together, and dropping any one of them distorts this license.

It is a class limit. The statute states the line for the Class B license class generally. It is not written as a refrigeration-endorsement figure, and no separate refrigeration-specific tonnage or heating line appears in any source retrieved for this endorsement. This guide prints the limit as what it is — the boundary of the class this license belongs to — and prints no second, colder number beside it.

It is a per-unit limit. The limit applies per complete individual unit (16 TAC § 75.22(c)): in a building or complex with multiple units, combined capacity may exceed 25 tons or 1.5 million BTU/hour so long as each individual unit does not. For refrigeration work the reading is concrete: a store’s refrigeration plant is assessed unit by unit as the rule frames units, not as one property-wide tonnage — and a single unit above the line is outside the license however small the building around it. “Cooling capacity” itself is defined as nominal tonnage of compression equipment based on 40°F suction temperature and 105°F condensing temperature (§ 1302.002(9)), so the measurement against the line uses the defined nominal figure.

It is enforced as classification law. Performing or offering work not authorised by the license’s classification or endorsement is a violation. The endorsement axis and the class axis are independent: the right endorsement at the wrong scale is outside the license, exactly as the wrong endorsement at the right scale would be. And the class is not a terminus — a Class B licensee may upgrade an endorsement to Class A by passing the Class A examination for that endorsement (§ 75.22(d)).

The license’s form rules complete the frame: the term is 1 year; licenses are not transferable; a contractor holding endorsements of different classes receives a separate license number for each endorsement, with concurrent expiration dates, printed on a single document; and a contractor holding two licenses may hold only one endorsement per license, both under the same business affiliation and addresses (§ 75.22(e)–(f)). The license number encodes title, class, number, and endorsement code — R for this endorsement, C for the holder of both.

The endorsement: two definitions, one credential

A contractor license must be endorsed with environmental air conditioning, with commercial refrigeration and process cooling or heating, or with both (§ 1302.254(a)). The compound name is one endorsement. TDLR’s application page may list the two phrases as separate descriptive items; the statute and the rule codes combine them into the single R endorsement, and no separate process-cooling contractor program may be split out of it.

Commercial refrigeration (§ 1302.002(6)) is the use of mechanical or absorption equipment to control temperature or humidity to satisfy the intended use of a specific space — cold in service of what a space is for. Process cooling or heating (§ 1302.002(15)) includes controlling temperature, humidity, or cleanliness solely for production requirements or the proper operation of equipment — conditions in service of making and running. Both stand apart from environmental air conditioning, which treats air for human comfort requirements (§ 1302.002(11)). The partition question for any job is what the controlled condition serves: occupants, a space’s intended use, or a production process — and then, separately, whether each individual unit sits inside the class line.

Inside the work: the loop boundary and its companions

Process scope is bounded by system architecture (§ 75.100(d)). Process cooling or heating work does not include cryogenic work, and is limited to piping and equipment in the primary closed-loop portions of processing systems containing a primary process medium. The licensed/unlicensed boundary then runs by sequence: after a licensee has deactivated and rendered inert a primary closed-loop system, an unlicensed person may perform maintenance, service, and repairs on the secondary open-loop components. The Class B limit sits on top of these rules, not instead of them: a process job must satisfy the loop boundary, the endorsement, and the per-unit class line to be in scope for this license.

Wiring carries an endorsement-specific permission: commercial refrigeration control wiring of any voltage may be installed by a licensee holding this endorsement if on the equipment side of the disconnect (§ 75.100(a)(3)) — distinct from the general rule under which licensees install and service control wiring of 50 volts or less, and conditioned on the disconnect’s equipment side. General edges: licensees may connect the appliance to the electrical line or disconnect provided and replace or reconnect systems or components of the same or lesser amperage; fuel-gas piping by a licensee is limited to the portion between the appliance and the existing piping system, connected at an existing shut-off valve, with existing piping, stops, and shut-off valves unaltered (§ 75.100(b)(1)); system testing may be performed without a contractor license while system balancing requires one (§ 75.100(f)); and equipment exemptions include residential refrigerators, freezers, and ice machines (§ 1302.058; § 75.30(a)(5)) — an exemption line, not a scope grant.

The gate: the full contractor route

No endorsement-specific experience gate for this endorsement is stated in any source retrieved, and the statute states no separate, lower experience gate for Class B: the contractor gate governs this program entire. The applicant must be at least 18 years old (§ 1302.255(a)(1)) and satisfy one route — at least 48 months of practical ACR-related experience under the supervision of a licensed ACR contractor in the preceding 72 months (§ 1302.255(a)(2)(A)), or a technician certification held for the preceding 12 months plus at least 36 months of practical experience under a licensed contractor in the preceding 48 months (§ 1302.255(a)(2)(B)) — with equivalent out-of-state experience or licensure creditable as the executive director determines (§ 1302.255(a-1)).

Education converts at fixed rates (§ 1302.255(c)–(e)): a 4-year degree or diploma in air conditioning, refrigeration, or mechanical engineering or technology counts as 24 months; a 2-year associate degree, diploma, or certification program primarily focused on ACR work counts as 12 months, the institution holding the required Texas higher education authority or an approved equivalent; every 2,000 hours of apprenticeship on-the-job training counts as 12 months; verified military ACR training and experience and specified governmental-entity ACR experience also qualify. Experience is documented on an Experience Verification Form completed by the supervising person(s) — the applicant must not complete it — and TDLR conducts a criminal history background check on all applicants.

Completion mechanics (§ 75.20(a)): approved-form application; eligibility satisfied as of the filing date (§ 75.21(a)); examination passed; required fees submitted; proof of insurance after passing. All requirements, including passing the examination, must be completed within 1 year of the application filing date. Scheduling opens only after TDLR approves eligibility and PSI issues its eligibility notice; the examination taken is the one corresponding to the class and endorsements selected on the application.

The sitting: counts, time, books, conduct

PSI delivers the examination by computer under its Candidate Information Bulletin, © 2026, updated July 9, 2026. Structure, kept split as published: 100 scored items plus 5 non-scored items — the non-scored items unscored, with extra time allotted for them — in 170 minutes for the scored examination, plus 10 minutes for the non-scored items. No merged total is printed for either measure, because none is published in that form.

The sitting is open book under handling rules that make the books part of the preparation: only references on the PSI Examination Reference Material List, brought by the candidate; highlighting, underlining, and notes permitted before the session; permanent index tabs only; no writing, highlighting, or marking during the session; no temporary or homemade tabs; no additional loose or adhered paper. The technical references verified for this examination are Modern Refrigeration and Air Conditioning, 22nd edition, 2025, and the ADI Duct Size Calculator. References stated for the environmental examinations are not in this list: the record states them for those examinations, and a candidate who carries another endorsement’s apparatus list into this room has misread the record.

On the day: arrive 30 minutes early; present one valid government-issued photo identification matching the TDLR eligibility record; calculators limited to non-programmable, silent, battery-operated models without paper-tape printing or an alphabet keyboard. The score shows on screen immediately; an official score report is printed at the site; a candidate who does not pass receives a diagnostic report by subject area. All ACR examinations are available in English and Spanish at no additional cost. The sourced examination is computer-based; no practical, hands-on, or drawing component is stated in any source retrieved, and this guide claims neither its presence nor a verified absence beyond that record.

The outline this guide does not print

This guide prints no content outline for this examination — no subject weights, and no Texas Laws and Rules count. The position is deliberate: no Commercial Refrigeration outline cell appears in the Texas fact record this package is built from, and whether a Texas Laws and Rules subject area sits inside the Commercial Refrigeration examinations — and at what count — is not verified in that record. Counts verified for other Texas examinations belong to those examinations; transferring them across endorsements or classes would publish invented weights for this sitting. Texas sets no separate Business and Law examination for ACR contractors as a structure; beyond that structural point, this record verifies no laws-and-rules figure for this program, and none is stated. Preparation should be organised by the verified anchors: the endorsement’s definitions, the correctly attributed class limit, the loop and wiring boundaries, the reference list, and the tested editions. The passing standard is stated only as the rule states it: “A passing grade is 70%” (16 TAC § 75.21(b)).

Three code layers, kept apart

Tested. From the PSI bulletin banner, verbatim: “Effective September 1, 2026, the examinations will be referenced to the 2024 International Fuel Gas Code, the 2024 International Mechanical Code, and the 2024 Uniform Mechanical Code” — stated for the ACR examinations generally, including this one. Both mechanical codes stand in the tested trio with the fuel gas code, in 2024 editions from that date.

Applicable. Rule § 75.110’s applicable codes were the 2021 editions for work through August 31, 2026 and are amended to the 2024 editions effective September 1, 2026 — an alignment effected by published amendment, with the pre-amendment interval’s “examination ahead of adoption” framing belonging to that interval.

Municipal. The practice standard in a municipality is the code adopted by that municipality’s ordinance; where no code has been adopted, § 75.100(e)(2) supplies defaults — residential defaults from the residential, fuel gas, and energy codes, commercial defaults from the uniform-or-international mechanical code with the fuel gas and energy codes. Earlier edition listings in older bulletin material are superseded, are not restated in this guide, and are no basis for preparation. Federal EPA Section 608 technician certification is a separate federal credential with its own PassProfessor program; no source retrieved makes it a condition of this state license.

Dollars, insurance, renewal, retakes — each at its layer

Application layer: TDLR contractor application fee $115. Examination layer: PSI fee for this examination $60; cancellation or rescheduling without forfeiture requires notice 2 days before the scheduled date; late arrival, a missed sitting, a late cancellation, or lack of proper identification forfeits the fee. Renewal layer: on-time renewal $65 for the 1-year term; late renewal at 1.5 times the fee when expired 90 days or less, 2 times when expired more than 90 days but less than 18 months, and 2 times with executive director approval when expired at least 18 months but less than 3 years (Occupations Code § 51.401; 16 TAC § 60.83). No ACR contracting on an expired license. The layers are never merged into one cost figure here.

Insurance — Class B levels, in the Class B package. Commercial general liability of $100,000 per occurrence, $200,000 aggregate, and $100,000 aggregate for products and completed operations (16 TAC § 75.40(b)), with proof submitted after passing the examination. If a licensee holds both Class A and Class B licenses, a single policy satisfies both if it meets the Class A minimums (§ 75.22(g)) — a single-policy rule, not a merging of the classes’ figures, each of which is stated in its own class’s package. A licensee who does not contract with the public may request a written insurance waiver, and then may not perform or offer ACR contracting with the general public (§ 75.40(e)–(f)).

Continuing education. Renewal requires 8 hours of department-approved continuing education, including 1 hour of Texas law and rules (§ 75.25(b)) — within the term of the current license for a timely renewal, or within the 1-year period immediately prior to the renewal date for a late renewal (§ 75.25(c)); no credit for the same course twice; the completion certificate retained 1 year. Begin renewal 30 to 60 days before expiration.

Retakes. Scheduling a retake with PSI opens within 24 to 48 hours of a failed examination; retakes are unlimited through the eligibility period — until the application expires, 1 year from submission — after which a fresh application is required.

Errors this guide exists to prevent

Misattributing the limit. The 25-ton and 1.5-million-BTU/hour line is the Class B license-class limit, per individual unit — not a refrigeration-specific figure, and not a property total. Both misreadings distort bidding in opposite directions. Splitting the endorsement into separate refrigeration and process-cooling credentials that do not exist in this record. Importing another examination’s outline or references — nothing verified for the environmental sittings describes this one. Assuming a discounted gate: no lower Class B or endorsement-specific experience route is stated in the sources. Dropping a boundary condition — primary closed loop only, no cryogenics, the wiring permission only on the equipment side of the disconnect, unlicensed secondary-loop work only after a licensee’s deactivation. Merging the counts, the times, the code layers, or the dollars. Completing the verification form oneself, missing the one-year completion clock, or submitting insurance proof before passing. And quoting the other class’s insurance figures as this class’s.

Texas Commercial Refrigeration Class B in one view

In one view, this license is bounded precision on the cold side: one combined endorsement defined by space and production, a class limit that belongs to the class and is measured per individual unit, process boundaries that run through loops and disconnects, a full contractor gate, a single open-book sitting described only as far as the record verifies, code editions in three layers, and a yearly renewal against eight hours of education and Class B insurance levels — with the Class A examination open as the upgrade route. The candidate who attributes the limit correctly, keeps the endorsement whole, and holds every layer apart is studying the license Texas actually issues. The companion program page at /texas-acr-contractor-commercial-refrigeration-class-b-exam-prep/ describes the PassProfessor program built on that design.

Tell me when enrollment opens. The Texas ACR Contractor — Commercial Refrigeration Class B program is in the works and enrollment is not yet open. Leave an email address and PassProfessor will write to you when the program is ready — and only about this program.

Frequently asked questions

Is the Class B limit a refrigeration limit?

No. It is the license-class limit (§ 1302.253), stated for Class B generally and applied per complete individual unit (§ 75.22(c)). No refrigeration-specific tonnage figure appears in the sources.

What does the endorsement cover?

One combined endorsement — Commercial Refrigeration and Process Cooling or Heating: refrigeration controlling temperature or humidity for a space’s intended use (§ 1302.002(6)), and process work controlling conditions solely for production or equipment operation (§ 1302.002(15)).

How many items, and how long?

100 scored items plus 5 non-scored items; 170 minutes for the scored examination plus 10 minutes for the non-scored items — published split, stated split.

What score passes?

The rule states it verbatim: “A passing grade is 70%” (§ 75.21(b)).

Why is no outline printed?

No Commercial Refrigeration outline appears in the Texas fact record — including whether any Texas Laws and Rules area or count sits in this exam. Nothing is borrowed from other Texas examinations.

Where does process work stop?

At cryogenic work, which is excluded, and at the primary closed loop. Secondary open-loop work opens to unlicensed persons only after a licensee has deactivated and rendered the primary system inert. The per-unit class limit applies on top of these boundaries.

Is there a shorter route into Class B?

None is stated in the sources. The full contractor gate applies, and a Class B licensee may later upgrade an endorsement to Class A by passing the Class A examination for it (§ 75.22(d)).

What does it cost, layer by layer?

TDLR application $115. PSI examination $60. Renewal $65 per 1-year term, late at 1.5 or 2 times the fee on the published schedule.

What insurance does Class B require?

$100,000 per occurrence, $200,000 aggregate, and $100,000 aggregate for products and completed operations (§ 75.40(b)), with proof submitted after passing the examination.

If I fail, how soon can I sit again?

Retake scheduling opens within 24 to 48 hours, with unlimited retakes through the eligibility period — 1 year from application submission.

Is PassProfessor affiliated with TDLR or PSI?

No. PassProfessor is an independent preparation provider. TDLR alone licenses and approves eligibility, and PSI delivers the examinations.

When does enrollment open for the PassProfessor program?

The program is in the works and enrollment is not yet open. Leave an email address on this page and PassProfessor will write to you when the program is ready — and only about this program.