Oklahoma licenses its Mechanical Journeyman — HVAC Limited through the Oklahoma Construction Industries Board under the Mechanical Licensing Act. The Limited category is defined by a cap measured appliance by appliance — cooling including process piping at or below 25 tons, and heating including process piping at or below 500,000 Btu per hour per appliance — and its journeyman examination is a single trade-only sitting through PSI: 60 questions in 180 minutes, open book, passed at 70 percent, which is 42 correct. This guide works through the credential, the sitting, and the route between them in full. The companion program page is at /oklahoma-mechanical-journeyman-hvac-limited-exam-prep/.
This program is part of the expanding PassProfessor catalog — join the notify list and we’ll email you when enrollment opens.
The credential at a glance
| Item | Verified position |
|---|---|
| Program | Oklahoma Mechanical Journeyman — HVAC Limited: the trade-only journeyman examination in the Limited mechanical HVAC category |
| Regulator | Oklahoma Construction Industries Board (CIB), 2401 NW 23rd St Suite 2F, Oklahoma City, under the Mechanical Licensing Act, 59 O.S. Chapter 43A, and OAC Title 158, Chapter 50 |
| Examination vendor | PSI, under the Candidate Information Bulletin effective September 11, 2026; the CIB determines eligibility and approves the applicant, who then schedules with PSI |
| Examination form | 60 questions, 180 minutes, open book, trade only — there is no Business and Law portion for this license |
| Passing standard | 70 percent, printed by PSI as 42 of 60 |
| Content outline | Electrical Knowledge and Controls 15 · Natural Gas 9 · Air Distribution Systems 10 · Refrigeration and Air Conditioning Systems 13 · Heating Systems 10 · Safety 3 — 60 items in full |
| Scope | Limited mechanical HVAC: cooling including process piping at or below 25 tons; heating including process piping at or below 500,000 Btu per hour per appliance; natural gas piping, refrigeration, and sheet metal |
| Tested codes | International Mechanical Code and International Fuel Gas Code, 2018 or 2024 with Oklahoma Revisions, on the transition dates stated in this guide; adopted Oklahoma codes are the 2024 editions effective September 14, 2026 |
| Administrator note | PassProfessor is independent and is not affiliated with the Oklahoma Construction Industries Board or PSI |
Why this guide is organized around a cap
Most journeyman guides are organized around the examination outline, and this one covers the outline in full below. But the Limited credential has a second organizing principle the Unlimited credential does not: a size boundary written into the category itself. Every fact about this license runs through two numbers and one qualifier. The numbers are 25 tons and 500,000 Btu per hour. The qualifier is per appliance, and it attaches to the heating figure. A candidate who holds those three elements precisely, without drifting into per-building or per-system readings, has mastered the distinction this credential exists to draw. This guide therefore returns to the cap at each stage: category, experience, outline, and study method.
The twelve categories and where Limited sits
Oklahoma’s mechanical rules list twelve categories at OAC 158:50-5-2(b): (1) Limited mechanical HVAC; (2) Limited residential journeyman; (3) Limited residential installer; (4) Unlimited mechanical HVAC; (5) Natural gas piping; (6) Process piping; (7) Refrigeration; (8) Sheet metal; (9) Ground source piping; (10) Fueled Hearth Product Work; (11) Petroleum refinery journeyman; and (12) Medical gas journeyman. This program serves category (1) only. The stand-alone categories are each taken by a separate examination and are separate programs; holding the Limited HVAC license does not itself confer a stand-alone Refrigeration, Sheet Metal, Natural Gas Piping, or Process Piping category, even though refrigeration, sheet metal, and natural gas piping appear inside the Limited category’s own scope sentence. Scope inside Limited runs to the Limited caps and no further.
The duties line runs across all categories. A journeyman performs mechanical work within a licensed category without direct supervision, while employed by an HVACR contractor, but contracts work only through a contractor. A contractor additionally plans, contracts, supervises, or furnishes labor and materials. An apprentice is registered, works in the same category as the supervising licensee, and works under the direct supervision of a licensed mechanical contractor or journeyman; no more than three apprentices may work under one licensed contractor or journeyman. The Limited journeyman therefore stands in the middle of the ladder: unsupervised in the work, bound to perform it under a contractor’s contracting authority.
The route, step by step
Step one — build verifiable experience. Experience counts when it is mechanical experience employed by a licensed mechanical contractor, or a Committee-approved means including United States military service. One year equals 2,000 hours. Experience gained in Oklahoma requires a Board apprentice registration for that period; experience obtained while unregistered does not count, except experience lawfully obtained under applicable federal or state law. All applicants must be 18 or older, and the experience affidavit must be signed and notarized by a certifier with personal knowledge.
Step two — apply, sit, and hold. Apply to the Board, which determines eligibility and approves the applicant, who then schedules with PSI; application and its fees must be received no less than three working days before the examination date, the application fee is forfeited if the applicant fails to meet minimum qualifications, and eligibility approval carries no expiration date. Sit the trade examination — 60 questions, 180 minutes, open book — under the passing standard and sitting rules set out below. Then hold the license on its birth-month clock, renewing on the Board schedule with the continuing education duty set out in the renewal section below. There is no bond or insurance activation step for this journeyman license; that step belongs to the contractor tier alone.
The experience gate in full
The journeyman gate at OAC 158:50-9-1(b)(1) offers a standard route and a ladder of education substitutions. The standard route is three years of verifiable experience in the category. The substitutions pair Committee-approved education with a reduced experience term: a program of 1,000 hours or more plus one year of experience; 500 hours or more plus two years; 375 hours or more plus two and a quarter years; 334 hours or more plus two and a third years; or 250 hours or more plus two and a half years. Equivalent verifiable United States military experience is its own route, as is a special certification required for the category. A current, good-standing out-of-state license meeting the same steps may expedite processing or support reciprocity, under the mechanism described below. Read the ladder as the rule writes it: each rung is a complete alternative, and no rung may be averaged with another. The contractor gate is this framework plus one additional year — four years on the standard route — and that fourth year is the tier above’s requirement, not a Limited journeyman requirement.
The endorsed-apprentice route: this category only
Oklahoma gives this Limited category one route no other category in this guide’s family carries. A registered apprentice at least 17 years old who has completed a Committee-approved formal educational program of 1,000 hours or more, with no grade lower than 70 percent in all trade courses, and who is in good standing with the school, may be approved to sit for the HVAC Limited journeyman examination early — before the experience year is complete. An endorsed apprentice is one who has passed that examination and is completing the required one year of verifiable experience as a registered apprentice. If the experience is completed within three years of the passing score and the apprentice is at least 18, the Limited journeyman license issues without further examination, on the journeyman application and fees — $75 in total, being the $25 application fee and the $50 initial license fee on the current Board schedule. Three disciplines protect the route from misreading. First, it reaches the HVAC Limited journeyman examination only — not the Unlimited examination or any contractor examination. Second, the grade condition is course-by-course, not an average. Third, the year of experience is deferred, not forgiven: the license waits on its completion, inside the three-year window, at or after age 18.
The sitting itself
The examination is delivered by PSI under the Candidate Information Bulletin for the State of Oklahoma — Electrical, Mechanical, Roofing, and Plumbing Examinations, effective September 11, 2026. The Board determines eligibility first; scheduling follows approval. The form is 60 questions in 180 minutes — three minutes per question on average — open book, trade only. No numeric pretest count is published: the bulletin’s general section states only that experimental, unscored items may be embedded, and candidates should distrust any source that prints a precise unscored figure for this sitting.
Book handling is rule-bound. All mechanical examinations in the bulletin are open book, and the candidate brings their own references. Highlighting, underlining, and indexing beforehand are permitted. Writing in references before or during the examination is not permitted. Tabs must be permanent only. Exam-day rules complete the frame: arrive 30 minutes early; present one valid signature-bearing photo identification; a silent, non-printing, non-programmable calculator is permitted; a magnifying glass is available on request. Where a reference conflicts with a legal requirement, the legal requirement controls, and state-specific law controls conflicts — when a general reference and Oklahoma law point different ways, the sitting credits the Oklahoma answer.
Retakes follow a stated ladder. After a first failure, 30 days must pass; every failure after and including the second requires 90 days. Examination misconduct brings expulsion, an invalid examination, and disqualification from retaking for not less than 30 and not more than 365 days as determined by the Board’s Administrator. The ladder rewards candidates who treat a first sitting as the sitting: the cost of a casual attempt is measured in months, not days.
The pass standard, stated as published
The passing standard is 70 percent, and PSI prints the raw count beside it for this examination: 70 percent is 42 of 60. Percentages are the published form in Oklahoma, and this guide states the standard only in that form. The raw count belongs to this form — 42 is the count for a 60-question sitting, and it does not travel to any other Oklahoma examination. Other trades and other portions inside the same PSI bulletin carry different standards that belong to those examinations; only the figure in this section governs the Limited journeyman sitting.
The outline in full, area by area
The bulletin accounts for all 60 items across six areas, printed here in full and only in full: Electrical Knowledge and Controls, 15; Natural Gas, 9; Air Distribution Systems, 10; Refrigeration and Air Conditioning Systems, 13; Heating Systems, 10; Safety, 3.
Electrical Knowledge and Controls — 15. The largest single area, one quarter of the sitting. Capped equipment still runs on controls, disconnects, wiring methods, and control sequences, and the journeyman who cannot reason about the electrical side cannot commission or troubleshoot the mechanical side. Study this area as applied work — reading a control arrangement, tracing a fault, checking a requirement against the installation described.
Refrigeration and Air Conditioning Systems — 13. The second block, and the area where the Limited cap does its quietest work. The category authorizes cooling including process piping only at or below 25 tons, so technical fluency and scope fluency are examined together: knowing how a system works, and knowing whether the system described is Limited work at all.
Heating Systems — 10. Level with air distribution, and the home of the per-appliance rule. Read heating items with the qualifier permanently switched on: the category figure is 500,000 Btu per hour per appliance. Scenarios presenting several appliances, or one appliance near the line, test whether the candidate applies the cap to each appliance in turn instead of summing the plant. That habit — appliance first, total never — is the most portable skill this guide can teach.
Air Distribution Systems — 10. A ventilation (duct) system is named first in the scope sentence, and the area carries the ACCA Ductulator on the reference list. Items reward candidates who size, read, and reason about distribution as a system: the air side is where a correctly capped plant still fails the occupant if the distribution is wrong.
Natural Gas — 9. A compact, distinct area matching the natural gas piping named in the scope sentence and the fuel gas code on the reference list. Its nine items are few enough that each carries weight; candidates who treat gas as a footnote to heating will feel the loss.
Safety — 3. The smallest area in the accounted outline. Its size is a weighting fact about this sitting, not a judgment about the field, where safety duties run through every task the other five areas describe. Prepare safety as part of each technical area as well as in its own right.
References and editions: two layers, three dates
The tested reference list for this examination includes the ACCA Ductulator; the International Mechanical Code, 2018 or 2024, with Oklahoma Revisions; the International Fuel Gas Code, 2018 or 2024, with Oklahoma Revisions; Modern Refrigeration and Air Conditioning, 20th, 21st, or 22nd editions, or Refrigeration and Air Conditioning Technology, 5th edition (2005); the Manual J reprint (2006), which is the manual item on this Journeyman Limited list; Mathematics for Plumbers and Pipefitters, 8th edition; and OSHA 29 CFR Part 1926. NCCER HVAC Books 1–4 are additionally allowed but were not used in examination development. Two allowances inside the list carry their own sunsets: the 22nd edition of Modern Refrigeration became usable as of August 13, 2026, while the 20th edition of that work and the 5th edition (2005) of Refrigeration and Air Conditioning Technology are each no longer allowed starting November 1, 2026.
Three dates govern the code layer, stated as the bulletin states them. The transition note reads, for each code-alternating list: starting September 14, 2026 the 2024 code can be used; as of December 14, 2026 the 2018 code will no longer be used or allowed. The tested layer therefore permits either the 2018 or the 2024 editions with Oklahoma Revisions during the window; after December 14, 2026 the 2018 editions leave the room entirely, and the durable tested key is the 2024 editions only. Study material in the PassProfessor program keys to the 2024 editions; no material depends on a provision that exists only in the 2018 editions or that differs between 2018 and 2024.
The adopted layer is stated separately, on purpose. Oklahoma’s adopted field codes, set by the Oklahoma Uniform Building Code Commission, are the 2024 editions with Oklahoma amendments, effective September 14, 2026. Adoption governs the work in the field; the bulletin governs the sitting. The two coincide in edition from September 14, 2026, but they remain different instruments.
Fees, in their instruments
Every dollar in this route belongs to an instrument, and the instruments are never merged. The examination fee is PSI’s: $92 for this examination, nonrefundable and nontransferable. The rule layer explains the mechanism — the Board or its designated representative may collect the actual cost of the examination, posted at the testing site, with the unit testing fee set as the negotiated amount under its statutory cap — and the amount PSI charges is the $92 stated here. Board fees are payable to the Board on the current journeyman schedule at OAC 158:50-9-2, as charged on Board application forms: application $25; initial license $50; the two together are $75 at application; renewal $75; renewal late fee $25. A one-time low-income fee waiver exists at OAC 158:1-3-13(c). Hold the layers apart: $92 to the vendor for the sitting, $75 to the Board at application, $75 at each renewal, $25 if a renewal runs late. No other Board figure belongs to this license, and figures belonging to other tiers or other schedules are not part of this route and are not printed in this guide.
One absence deserves the same emphasis. The contractor tier activates its license, after both contractor parts are passed, on a corporate surety bond and a commercial general liability insurance certificate. No source for this journeyman license states any bond or insurance proof as a condition of issuing or holding it, so the journeyman route contains no bond step and no insurance step.
Renewal, reinstatement, and continuing education
A mechanical license runs not more than one year and expires the last day of the licensee’s birth month each year. The renewal application and fee must be delivered or mailed on or before that date — a personal date that moves with the licensee, not a single statewide deadline. An expired license may be reinstated with the renewal fee, the late fee, and proof of all renewal requirements. No license may be issued or renewed until all outstanding fines owed to any Board division are paid, and surrendering a license during a Board investigation is treated as revocation for one year.
Continuing education is six hours every three years, completed within the 36 months preceding license expiration, required for renewal of any mechanical contractor or journeyman license. Both the course and the instructor must be approved in advance by the Mechanical License Committee, with an emergency substitute-instructor exception on written notice within seven days. Course material covers the codes adopted by the Oklahoma Uniform Building Code Commission and approved trade subjects, including the Mechanical Licensing Act, OAC Chapter 50, and OAC 158:10. Licensees are exempt for three years from the date they passed their current licensing examination. One credit hour is at least 50 minutes of instruction plus a 10-minute break. Education completed while a license is expired applies to the period preceding expiration, and a further six hours is still owed for the subsequent period. Category exemptions elsewhere in the framework belong to other categories; none applies to this HVAC category.
Reciprocity, stated as a mechanism
Oklahoma reciprocity is not a list of states; it is a mechanism with conditions. It requires a written reciprocity agreement between the applicant’s state and Oklahoma, and a substantial-equivalence showing across five elements: category regulation and licensure; experience required to sit for the examination; continuing education requirements; adopted codes; and the examination itself, including pass score, category-specific examinations, and written form. The other state must recognize Oklahoma licenses. The applicant must be currently licensed, must have lawfully practiced one year immediately prior in that state, must show no pending disciplinary matters by certified statement, and must have obtained the license by examination. Fees are the standard application and initial license fees, nonrefundable; the Committee reviews and the Board decides. Names of partner states are not in the rule, and this guide prints none.
A study plan built on the cap and the weights
First, fix the scope sentence. Memorize the category as the rule writes it — ventilation (duct) system and/or cooling including process piping at or below 25 tons, heating including process piping at or below 500,000 Btu per hour per appliance, natural gas piping, refrigeration, and sheet metal — and drill the per-appliance application until sorting described installations into Limited and beyond-Limited is automatic. Second, weight the outline honestly. Electrical knowledge and controls earns the largest share of study time because it earns the largest share of the paper; refrigeration and air conditioning follows; heating, air distribution, and natural gas take level, serious blocks; safety is studied inside every block and again on its own. Third, build the tabbed set early. The sitting is open book with the candidate’s own references, permanently tabbed, highlighted and indexed beforehand, with no writing in the books; a set assembled in the final week is a set the candidate cannot yet navigate. Fourth, key everything to 2024. Work from the 2024 code editions with Oklahoma Revisions, respect the November 1, 2026 reference sunsets, and let no study note rest on a 2018-only provision. Fifth, practice the conflict rule. In mixed timed sets, whenever a general reference and Oklahoma law diverge, answer with Oklahoma law.
The errors this examination is built to catch
Summing the heating plant. Adding appliances together and comparing the total to 500,000 Btu per hour misreads the rule; the cap runs per appliance. Dropping the qualifier in speech, then in judgment. Candidates who shorten the cap to “500,000 Btu” in their notes soon apply it to buildings and systems, and the scope items collect the difference. Importing the contractor structure. Expecting a Business and Law portion, a contractor fee, or a bond step on the journeyman route wastes preparation and misstates the route. Borrowing another form’s weights. The Limited outline is its own accounting of 60 items; study weighted to a different form’s proportions misallocates the scarcest resource, which is time. Pacing by an invented pretest count. No numeric count is published; the sitting is 60 questions in 180 minutes as presented. Studying the adopted layer as if it were the tested layer. The field codes and the examination references coincide in edition and differ in instrument; the dates — September 14 and December 14, 2026 — decide which edition the room allows.
After the sitting
A passing score completes the examination step; the license itself issues on the journeyman application and its Board fees, and then runs on the birth-month clock described above. The endorsed apprentice’s variant is stated in its own section: pass first, complete the year, and the license issues without further examination inside the three-year window. For every holder, the working duties run continuously beneath the renewal cycle — work inside the category and its caps, contracting only through a contractor, no more than three apprentices under one licensee — and the six-hour education duty arrives on its three-year rhythm, with the post-examination exemption covering the first cycle. The credential rewards the same habit after the sitting that it rewarded inside it: read the figure, keep its qualifier attached, and stay inside the category as written. The companion program page at /oklahoma-mechanical-journeyman-hvac-limited-exam-prep/ summarizes the program itself.
Frequently asked questions
How many questions are on the Limited journeyman examination, and how long is it?
60 questions in 180 minutes, open book, through PSI. The examination is trade only; there is no Business and Law portion for a journeyman license.
What score passes?
70 percent, printed by PSI as 42 of 60.
What are the six outline areas and their counts?
Electrical Knowledge and Controls 15, Natural Gas 9, Air Distribution Systems 10, Refrigeration and Air Conditioning Systems 13, Heating Systems 10, and Safety 3 — 60 items in full.
How is the Limited heating cap measured?
Per appliance: heating including process piping at or below 500,000 Btu per hour per appliance. The cooling cap is at or below 25 tons, including process piping.
Which manual is on this examination’s reference list?
The Manual J reprint (2006) is the manual item on the Journeyman Limited list.
How much experience does the standard route require?
Three years of verifiable experience in the category, where one year equals 2,000 hours of mechanical experience employed by a licensed mechanical contractor. Approved education substitutes at the steps stated in this guide.
What does the route cost?
PSI charges $92 for the examination. Board fees are separate: $25 application and $50 initial license, $75 together at application; renewal $75; renewal late fee $25.
Which code editions should a candidate study?
The 2024 editions of the International Mechanical Code and International Fuel Gas Code with Oklahoma Revisions. The 2018 editions may be used during the transition window and will no longer be used or allowed after December 14, 2026.
How much continuing education does renewal require?
Six hours every three years, within the 36 months preceding license expiration, from a course and instructor approved in advance by the Mechanical License Committee. Holders are exempt for three years from the date they passed their current licensing examination.
When does enrollment open for the PassProfessor program?
The program is in the works and enrollment is not yet open. Leave an email address on this page to be notified when it is ready.