North Carolina licenses Heating Group No. 2 Contractor work through the State Board of Examiners of Plumbing, Heating, and Fire Sprinkler Contractors. Heating, group number two is an integral system for heating or cooling a building, producing conditioned air, with a mechanical refrigeration capacity in excess of 15 tons. This guide sets out the credential, the scope that defines it, the two-part examination, and the route between application and license.
This program is part of the expanding PassProfessor catalog — join the notify list and we’ll email you when enrollment opens.
The credential at a glance
| Item | Verified position |
|---|---|
| Program | North Carolina Heating Group H2 — the Heating Group No. 2 Contractor license |
| Regulator | State Board of Examiners of Plumbing, Heating, and Fire Sprinkler Contractors, 1109 Dresser Court, Raleigh, NC 27609 |
| Statutory scope | G.S. 87-21(a)(3): an integral conditioned-air system with mechanical refrigeration capacity in excess of 15 tons |
| Examination structure | Two parts, both required: a technical part and a Business and Law part (structure only in this guide) |
| Examination time | Technical part: 4.0 hours. Business and Law part: 1.5 hours |
| Book status | Open book — candidate-supplied approved references only |
| Passing standard | A grade of 70 of 100, on each part (21 NCAC 50 .0305) |
| Tested codes | 2018 North Carolina codes, built on a 2015 International Code basis |
| Administrator note | PassProfessor is independent and is not affiliated with the State Board of Examiners of Plumbing, Heating, and Fire Sprinkler Contractors |
The companion program page is at /north-carolina-heating-group-h2-exam-prep/. This guide goes deeper on the same verified record: how the tonnage line is drawn, how it aggregates, where the single-family boundary cuts it, and how the Board examines, renews, and supervises the license that follows.
First principle: the group is a sentence, not a trade label
Most licensing guides start with a trade and then attach a license to it. North Carolina works the other way for its Heating Groups. “Heating” is an umbrella term that means heating group number one, heating group number two, heating group number three, or any combination of them — G.S. 87-21(a)(7) — and each group is then defined by its own statutory paragraph. There is no general heating contractor license in this system that a candidate can hold loosely; there are three defined scopes, three examinations, and a contractor qualifies in the group whose paragraph matches the work.
For the second group, the paragraph at G.S. 87-21(a)(3) reads: “Heating, group number two means an integral system for heating or cooling a building consisting of an assemblage of interacting components producing conditioned air to raise or lower the temperature, having a mechanical refrigeration capacity in excess of 15 tons, and which circulates air.”
Read that sentence the way an examiner reads it. The subject is a system, not a unit. Its components interact — compressor, coil, air handler, ductwork, controls, working as one assemblage. Its product is conditioned air, raised or lowered in temperature. It circulates that air. And its mechanical refrigeration capacity sits in excess of 15 tons. A described installation that fails any element of that sentence is not described as group two work, however large or mechanical it feels. A candidate who internalises the sentence has the classification tool the whole examination quietly assumes.
The aggregation rule, worked slowly
21 NCAC 50 .0501(a) adds the rule that makes the tonnage line operational: multiple units serving interconnected space and aggregating more than 15 tons are included in Heating Group 2 systems, whether or not separately ducted or controlled.
The single-family carve-out, stated as a boundary
The last sentence of G.S. 87-21(a)(3) is easy to miss because it sits inside the second group’s own paragraph, and it changes the group’s reach completely: systems installed in single-family residences are included under heating group number three, regardless of size.
A residence does not become group two work by growing. A very large single-family installation — the kind of plant where tonnage alone would suggest this group in any other building — is routed by that sentence to the third group. The Board’s rule at 21 NCAC 50 .0501(b) confirms the shape from the licensing side: installation of heating and air conditioning systems or components in single-family dwellings requires a Heating Group 3 license, as do systems of 15 tons or less in non-residential structures, with stated exceptions where heat is provided by hot water or steam in a Heating Group 1 system, or cooling is provided by a unitary appliance such as a window unit, for which no license is required on that point.
This guide states the carve-out only as what it is for an H2 candidate: a boundary. It tells the H2 applicant where this license does not extend, and it tells the working H2 contractor when a residential opportunity belongs to a differently licensed colleague or to a second qualification held in the third group. It does not convert this program into a program about the third group; the scope, examinations, and preparation for that license are a separate package.
The neighbouring groups, for contrast only
Contrast sharpens a definition, so the two neighbours are stated here in their own statutory terms and then left alone.
Heating Group No. 1, G.S. 87-21(a)(2), is the heating system of a building which requires the use of high or low pressure steam, vapor or hot water, including all piping, ducts, and mechanical equipment appurtenant thereto, within, adjacent to or connected with a building, for comfort heating. Its medium is water and steam; a boiler installation or replacement in such a system belongs to that group under 21 NCAC 50 .0507.
Heating Group No. 3, G.S. 87-21(a)(4), is the direct heating or cooling system at or below the tonnage line, together with the single-family inclusion above. Board plain language divides the air-side work accordingly: group two above the line, group three at or under it, with residences routed to group three at any size.
Group two’s own work rule is 21 NCAC 50 .0508(d): a Heating Group 2 license is required for the installation or replacement of equipment or ductwork in a Heating Group No. 2 system, unless exempted by G.S. 87-21(a)(3). And one shared line runs across the groups: under 21 NCAC 50 .0511, the contracting or installation of fuel piping from an approved fuel source at or near the premises to a point within the premises requires one of the Board’s plumbing, Heating Group 1, Heating Group 2, Heating Group 3, or Fuel Piping licenses, regardless of the nature of the system, equipment, or appliance served.
Who is engaged in the business
G.S. 87-21(a)(5) defines engagement broadly: a person, firm, or corporation who, for valuable consideration, verifies, inspects, evaluates, tests, installs, alters, or restores heating group work — or offers to do any of those — is deemed engaged in the business of heating contracting. A person who installs a heating system on property intended at installation for sale or primarily for rental is likewise deemed engaged without regard to receipt of consideration, unless exempted. A license must be obtained before engaging or offering to engage; submitting a bid is itself an offer. An individual may not perform in-scope work for any other person, firm, or body, in any compensation arrangement, unless issued the appropriate license (21 NCAC 50 .0510).
Eligibility: the experience gate and the application
The contractor experience gate is set by 21 NCAC 50 .0306(b). When submitting the application, an applicant for a heating examination shall present evidence of two years of full-time experience in the installation, maintenance, service, or repair of plumbing or heating systems related to the category for which a license is sought, whether or not a license was required for the work. Up to one-half of that experience may be academic or technical training related to the field. Part-time work below 40 hours a week, and part-time academic work below 15 semester or quarter hours, are prorated. The Board’s applicant outline states the same gate in working numbers: 2 years — 4,000 hours — of on-site full-time experience in the category sought, with up to one-half, stated as 45 quarter hours or 30 semester hours, available as directly related academic or technical training, and with experience hours from other states submittable. The statute sets the ceiling behind the rule: the Board may require experience as a condition of examination provided it may not exceed two years, up to one-half may be academic or technical, and registration is not required at the commencement of the experience period (G.S. 87-21(b)(3)).
The examination: two parts, one format, three shared Heating Group mechanics
The examinations are administered by PSI. The bulletin of record is the PSI Candidate Information Bulletin for the North Carolina Plumbing, Heating and Fire Sprinkler Contractors Examinations, updated August 25, 2026. The three Heating Groups share one format; only the technical content and references differ by group. Examinations are computer-based at seven PSI sites — Asheville, Charlotte, Winston-Salem, Raleigh, Fayetteville, Greenville, and Wilmington — and the score, reported as pass or fail, is given immediately at the centre.
Each person examined for a contractor license must pass both the business and law part and the technical part of the examination required by G.S. 87-21(b) (21 NCAC 50 .0301(b)). This guide treats the Business and Law part as structure only: it is a required part, it runs 1.5 hours — 90 minutes — it carries the same passing standard as the technical part, and it is subject to one exemption. The Business and Law part is not required if the applicant holds a currently active contractor license with this Board and passed the Board’s Business and Law examination after August 2003. No Business and Law subject content is built in this package.
The technical part runs 4.0 hours. The statute describes what the Board’s examination is designed to ascertain: the applicant’s technical and practical knowledge concerning analysis of plans and specifications, estimating costs, fundamentals of installation and design, codes, fire hazards, and related subjects as they pertain to the system category (G.S. 87-21(b)(3)). That sentence describes the written examination’s subject design; no hands-on, practical, or drawing component of either part is stated in the sources for this license, and this guide presents the sitting as the two computer-based parts described here.
On counts, this guide is deliberately silent, and the silence is the verified position. A count of items for the technical part and a count for the Business and Law part are not published in the current PSI bulletin, in 21 NCAC 50 section .0300, or in the Board’s examination and applicant information. No pretest, experimental, or unscored count is published either — the current bulletin states nothing about such items for these examinations. A candidate therefore prepares against time, book status, and reference set, which are published, and should treat any count offered from outside the Board’s and PSI’s primary documents as unsupported.
Book status and the room as it is actually run
Both parts are open book, restricted to candidate-supplied approved references. Only the books for the approved license category are allowed in the room. References must be original editions in hard, spiral, or ring binding — printed PDFs are not allowed. Commercially available permanent tabs are allowed, and the ICC Turbo Tabs loose-leaf inserts are the only approved divider inserts. Highlighting is the only permitted alteration; notes, formulae, and underlining may not be added. Pencils, scratch paper, calculators, and the North Carolina Heating and Plumbing Figures are provided at the site and must be returned. A candidate who arrives with unauthorised materials or devices is not allowed to test and must wait 90 days before rescheduling.
The passing standard, in the rule’s form
21 NCAC 50 .0305, headed Passing Grade, provides: “Examinations provided by the Board are based upon a maximum obtainable grade of 100 points, and a grade of 70 is required to pass.” Read with 21 NCAC 50 .0301(b), that standard governs both parts separately: a candidate must reach a grade of 70 of 100 on the technical part, and a grade of 70 of 100 on the Business and Law part. Passing one part does not carry the other.
Tested codes: the 2018 layer, on a 2015 basis
The examination basis is fixed by the Board’s Book Reference List and Requirements, effective July 1, 2025, and confirmed by the Board’s update of June 1, 2026: until further codes become effective, all examinations for plumbing, heating, fuel piping, and fire sprinkler licensing will be based on the 2018 edition of the codes.
The reference letters for this license are: A — North Carolina Administration Code and Policies, 2018 Edition; C — North Carolina Fuel Gas Code, 2018 Edition; D — North Carolina Mechanical Code, 2018 Edition; E — North Carolina Energy Conservation Code, 2018 Edition; F — North Carolina Residential Code, 2018 Edition; G — the Board’s Laws and Rules, 2025 or 2026 Edition, comprising G.S. 87 Article 2 and 21 NCAC 50; and H — Business and Project Management for Contractors, in its 6th or 7th edition in the NASCLA North Carolina plumbing, heating, and sprinkler edition, which belongs to the Business and Law part’s structure and is recorded here as a reference only.
The group-specific set for Heating Group No. 2 carries the load and refrigeration references the tonnage line implies: Manual J, 8th Edition version 2; Manual N, 5th Edition; Manual D, 3rd Edition, Volume 1; and Modern Refrigeration and Air Conditioning, 22nd Edition — the 21st Edition was allowed only until June 30, 2025. Each heating and cooling candidate also furnishes their own ACCA duct calculator slide rule. Builders of preparation material key each item’s citation to the matrix row for this exact group, because the reference sets differ across the three Heating Groups.
The field layer is stated separately, as it must be. The 2018 North Carolina Codes, effective January 1, 2019, include the 2018 North Carolina Ad-Hoc Committee amendments along with the 2015 International Codes, following a transition period from July 1, 2018 through December 31, 2018. The 2018 North Carolina Mechanical Code is based on the 2015 International Mechanical Code, effective January 1, 2019, with Building Code Council amendments from December 2017 through December 2022, including identified North Carolina errata. The 2018 North Carolina Fuel Gas Code was adopted June 13, 2017, effective January 1, 2019; in that code, references to the International Codes mean the North Carolina Codes, and North Carolina amendments are underlined in the published text. The North Carolina Building Code as adopted by the North Carolina Building Code Council is the minimum standard of competence for Board licensees under 21 NCAC 50 .0505(b).
Administration windows, rescheduling, and retakes
Approval starts a clock. The examination must be taken within 90 days of the notification date; the approval letter lists the authorisation period — that 90-day window — and the candidate and exam identification used to create the PSI account. Examinations must be given at least twice each year, and the Board may administer examinations by computer within 30 days after approving an application (G.S. 87-21(b)(6)).
Retakes are governed by the Board and the statute, not by any shorter vendor scheduling line. A person who fails any examination shall not be reexamined until after 90 days from the date last examined (G.S. 87-21(b)(6)). In Board process, a failing applicant waits 90 days and submits a Re-Examination Application, with the examination fee where retesting in the same classification, and with an updated criminal background report if the report on file is more than six months old. The failed portion may be retaken within six months of the date approved to take the examination without retaking the portion passed. An applicant who fails any part three times may be required by the Board to receive additional education before retaking, or to wait one year before retaking any portion. A failing applicant may, on written request, review the examination at a time and place determined by the Board (21 NCAC 50 .0308); in Board process, that review takes place in Raleigh before retesting.
The fees, layered and never merged
Three instruments, three payees, three moments. First, the Board layer: the application for a license by examination is $150, consisting of a $75 application fee and a $75 examination fee, and it is nonrefundable (21 NCAC 50 .1101(c)). Second, the vendor layer: the PSI examination fee is $75, charged through PSI and valid for one year from payment. The Board’s $150 and PSI’s $75 are different fees; neither absorbs the other, and this guide never adds them into a single application figure. Third, the license layer: the annual license fee for a plumbing, heating, and fuel piping contractor license is $150 (21 NCAC 50 .1102(a); G.S. 87-22 caps that annual fee at $150), paid on activation within the 45-day window above and at each annual renewal.
Renewal, reinstatement, and continuing education
All licenses expire on the last day of December in each year following issuance or renewal (G.S. 87-22); in Board terms, the license is renewed annually and every Board license expires December 31. The secretary-treasurer must send renewal notice at least one month in advance of expiration. In practice, invoices are mailed in early October and email notices are also sent, the renewal period begins 90 days before expiration — usually October 1 — and a licensee who receives neither an invoice nor a notice is still responsible for renewing. Failure to renew and pay during January increases the license fee by $25; the Board’s renewal invoice applies that processing fee where a renewal is not received correctly before January 31. The Board may require payment of all unpaid annual fees before reissuing a license.
Reciprocity and recognition, in their three separate layers
Three statements exist side by side in the sources, and this guide keeps them in their own layers rather than blending them into one promise. The Board’s applicant information states that there are no license reciprocity agreements with any other state, and that all persons desiring licensure with this Board must meet the Board’s requirements and satisfactorily complete the applicable examinations. The rule, 21 NCAC 50 .0310, provides that the Board shall grant license by reciprocity only pursuant to reciprocal licensing agreements worked out with various states after mutual review. The statute, G.S. 87-21(g), provides that the Board may, in its discretion, grant an equivalent license without written examination to contractors licensed by other states, on satisfactory proof of substantially equivalent qualifications and payment of the usual license fee.
Operating the license: firms, supervision, permits
A license may issue in the name of a corporation, partnership, or assumed or designated trade name where licensed officers, partners, owners, or full-time employees execute contracts to the extent of their qualifications in that name and exercise general supervision to completion (G.S. 87-26). The operating rules then attach to every location. Under 21 NCAC 50 .0404(a), in each business location from which licensed work is solicited, proposed, contracted, dispatched, or carried out, there shall be on duty — the lesser of 1,500 hours annually, or all hours during which those activities are carried out — at least one contractor licensee in the classification required, listed in that firm’s name at that location, with responsibility for contracts and general supervision. If a qualifying licensee is employed elsewhere, no work requiring a license may be performed by the firm on that qualification during those hours. Each licensee qualifies only the business location from which the majority of their work is carried out, and is listed on only one contractor license at any given time (.0405).
Supervision has two layers. General supervision requires review of the work by a licensee of the firm while the work is in progress (.0505(a)). On-site supervision requires a properly qualified licensee of the firm to personally perform on-site and in-person supervision and review on all work, before the work is covered or placed into service (.0520). The current license is posted in the business location, and its number appears on all proposals, contracts, and requests for permits (G.S. 87-21(e)); the firm’s qualification appears on contracts, proposals, permit applications, and telephone directory advertising (.0406(c)). A licensed contractor ensures a permit is obtained before commencing licensed work, and a request for final inspection within 10 days of the earlier of the system being made operational or placed in service (.0402(a)); failure on either point is evidence of incompetence or misconduct (.0402(d)).
The Board may revoke or suspend a license, or order reprimand or probation, for fraud or deceit in obtaining or renewing a license, for failure to comply with Article 2 or the Board’s rules, or for gross negligence, incompetency, or misconduct (G.S. 87-23(a)). Unlicensed practice is a Class 2 misdemeanor (G.S. 87-25), and the Board may seek superior-court injunctive relief under G.S. 87-25.1. No fine amount or term for that offence is stated in the sources behind this guide, and none is stated here. Refrigeration contractor licensing is not part of this Board’s system at all — it sits with a separate state board under 21 NCAC 60 — and no refrigeration-contractor proposition belongs in preparation for this license.
A study plan built on how this license is actually drawn
Study the 2018 layer as a layer. Work the 2018 North Carolina Mechanical Code and Fuel Gas Code as North Carolina texts — 2015 International Code basis, North Carolina amendments underlined and applied — and resist importing provisions from other editions or other states’ amendments. Keep the Board’s Laws and Rules beside the codes; both are examined.
Frequently asked questions
What is the statutory definition of Heating Group No. 2?
An integral system for heating or cooling a building, consisting of an assemblage of interacting components producing conditioned air to raise or lower the temperature, having a mechanical refrigeration capacity in excess of 15 tons, and which circulates air (G.S. 87-21(a)(3)).
How does the aggregation rule work?
Multiple units serving interconnected space and aggregating more than 15 tons are included in Heating Group 2 systems, whether or not separately ducted or controlled (21 NCAC 50 .0501(a)).
Why is a large single-family system not H2 work?
Because G.S. 87-21(a)(3) itself provides that systems installed in single-family residences are included under heating group number three, regardless of size.
What must a candidate pass?
Both parts: the technical part and the Business and Law part, each to a grade of 70 of 100 (21 NCAC 50 .0305 and .0301(b)), unless the Business and Law exemption for an active Board contractor licensee who passed that part after August 2003 applies.
How long does each part run?
The technical part runs 4.0 hours; the Business and Law part runs 1.5 hours.
Which code editions govern the sitting?
The 2018 North Carolina codes — on a 2015 International Code basis — with the Board’s Laws and Rules in the 2025 or 2026 edition. The 2024 North Carolina code is not in effect and is not the basis.
What happens after a failed part?
Reexamination is barred until after 90 days from the date last examined. The failed portion may be retaken within six months of approval without retaking the portion passed, on a Re-Examination Application under Board process.
Is PassProfessor the Board, or affiliated with it?
No. PassProfessor is an independent preparation provider, not affiliated with the State Board of Examiners of Plumbing, Heating, and Fire Sprinkler Contractors or with PSI. The companion program page is at /north-carolina-heating-group-h2-exam-prep/.
When does enrollment open?
The program is in the works and enrollment is not yet open. Leave an email address on this page and PassProfessor will write to you when the program is ready — and only about this program.