New Mexico MM-3 Heating, Ventilation & A/C Exam Guide: The Scope Line, the Six-Area Sitting, and the Clocks That Govern the Route

This guide works through the New Mexico MM-3 Heating, Ventilation & A/C credential end to end: the classification’s scope line at 14.6.6.11B NMAC, the qualifying-party system that holds the license, the open-book PSI trade examination of 100 questions in 245 minutes keyed to the Uniform Mechanical Code 2021, and the fee, bond and renewal instruments that surround it. The companion program page is at New Mexico MM-3 Heating, Ventilation & A/C Exam Preparation.

This program is part of the expanding PassProfessor catalog — join the notify list and we’ll email you when enrollment opens.

The credential at a glance

ItemVerified position
ClassificationMM-3 Heating, ventilation & air conditioning (HVAC), 14.6.6.11B NMAC; PSI examination title “MM-3 Heat, Vent and Air Conditioning”
RegulatorConstruction Industries Division (CID), Regulation and Licensing Department — CILA, NMSA 1978, Ch. 60, Art. 13
Trade examinationPSI, open book — 100 questions · 245 minutes
Passing standard, trade75% (75 points)
OutlineMotors, Controls, and Low Voltage Wiring 20 · Duct Work, Ventilation, and Exhaust 20 · Heating and Cooling General Knowledge 20 · Equipment and Components 15 · Refrigerants and Refrigeration 15 · Piping 10
Code layersTested: Uniform Mechanical Code, 2021 · Field: 2021 New Mexico Mechanical Code (14.9.2 NMAC) adopting UMC 2021 — the layers agree
ExperienceFour years (8,000 hours) within the last 10 years
Administrator notePassProfessor is independent and is not affiliated with the Construction Industries Division

How to read this guide

New Mexico facts live in three layers, and most candidate errors are layer errors. Statute facts come from the Construction Industries Licensing Act. Rule facts come from NMAC Title 14 — classifications and scopes in Chapter 6, fees in 14.5.5, the field mechanical code in 14.9.2. Bulletin facts — counts, minutes, outlines, room rules — come from PSI’s Contractor Examinations Candidate Information Bulletin, updated April 3, 2026. Where a layer is silent, this guide says so rather than filling the gap: no pretest count is published for these examinations, no fixed contractor license term is stated in the renewal rule, and the Business and Law examination is treated for structure only, because this program prepares candidates for the trade sitting.

The route, step by step

Step one — confirm the classification. Read the MM-3 scope line (next section) against the work the business actually performs. If the work sits in a neighbouring classification, this is the wrong route, however strong the candidate’s trade knowledge.

Step two — establish the qualifying party and the experience record. The business designates its QP, an individual 18 or older, and documents four years (8,000 hours) of classification-related experience inside the last 10 years, with any training credit calculated under the cap described below.

Step three — apply and be preapproved. All licensing requirements must be met within six months of CID’s receipt of the application or it expires with fees forfeited, and no PSI examination may be scheduled before preapproval.

Step four — sit both examinations inside their clocks. The QP tests within 6 months of eligibility, passes the trade examination and the Business and Law step within 1 year of each other, and keeps in mind that passing scores and the examination fee each remain valid for 1 year.

Step five — license, bond and hold. On passing, the license issues per classification on the CID fee instruments, the $10,000 bond is in force for the whole period of licensure, and renewal thereafter runs on form, signatures, fees and the maintained bond — with no coursework requirement for this tier.

The scope line, read closely

The rule’s sentence does four jobs at once, and the examination tests all four. It grants the core work — install, alter, repair, service and maintain HVAC air handling and refrigeration equipment and piping. It enumerates the equipment family — fans, coils, condensing units, self-contained packaged AC or heating units, evaporative cooling units, and ductwork and accessories including solar air heating — which is why evaporative cooling and solar air heating sit inside MM-3 rather than beside it. It grants two narrow connections: water, but only to existing valved outlets; and controls and control wiring, but only not to exceed 24 volts. And it permits bidding and contracting for structural alterations, electrical wiring and other incidental work provided it is performed by a validly licensed contractor — a contracting permission, not a performance permission.

Read against the grain, the same sentence marks the edges candidates most often blur. Extending water piping beyond an existing valved outlet is outside the grant. Controls work above 24 volts is outside the grant. Performing the incidental electrical or structural work with one’s own crew, rather than through a validly licensed contractor, is outside the grant. Work outside the scope of one’s classification violates the CILA, and the prime-contractor rule compounds it: bid only work whose major portion by dollars is yours, and subcontract the rest to properly licensed contractors. The handyman exemption at NMSA 60-13-3D(14) — one project at a time, compensation not exceeding $7,200 per year, casual and minor repairs, an annual declaration, no holding out as a contractor — never reaches this work at all, and expressly never applies to installation, connection or repair of electrical wiring, plumbing or gas fitting.

The classification boundary deserves one more pass. This guide builds MM-3 only. MM-1 Plumbing, MM-2 Natural gas fitting and MM-4 Heating, cooling and process piping are identified by name so a candidate can locate the boundary; they belong to a different preparation lane and none of their examination material appears here. MM-98 Mechanical is not an examination: there is no single MM-98 examination, and a QP qualifies for it through the component trade examinations plus business and law. The journeyman certificate tier — JR journeyman refrigeration and JSM journeyman sheet metal — is likewise a separate tier, treated in this guide only where its rules touch MM-3 practice, notably the requirement that a JR holder demonstrate compliance with the federal EPA recovery requirements before the certificate issues.

The trade outline in full

The outline is the examination’s own map of the trade, and its weighting is a study instruction. Three areas carry 20 questions each; the remaining three carry 15, 15 and 10.

Motors, Controls, and Low Voltage Wiring — 20

The joint-largest area joins the scope line’s sharpest limit: controls and control wiring not exceeding 24 volts are MM-3 work, and the sitting examines that territory at full weight. Candidates should expect the area to test motor and control reasoning together — how equipment is started, sequenced and limited — always inside the classification’s voltage boundary. Preparation that treats controls as an electrical afterthought misreads the outline: at 20 questions, this area equals ductwork and general knowledge.

Duct Work, Ventilation, and Exhaust — 20

Air movement is the second pillar. The area draws on the SMACNA duct construction standards in the reference list and on the duct calculator the room rules expressly allow — a ductulator or other slide or wheel duct calculator. The practical consequence is that sizing and layout fluency, performed with the allowed tool under time, is part of what is being measured. Candidates should practise duct calculations with the wheel in hand rather than by formula alone.

Heating and Cooling General Knowledge — 20

The third 20-question area is the trade’s shared foundation: the principles by which heating and cooling equipment moves heat, conditions air and behaves as a system. It is the area generic HVAC knowledge serves best — and the area where the New Mexico delta matters least — but at one-fifth of the paper it cannot be treated as background. Weak general knowledge caps the score no matter how strong the code work is.

Heating and Cooling Equipment and Components — 15

This area examines the equipment family the scope line enumerates: packaged units, condensing units, coils, fans, evaporative cooling units and their components, as installed, serviced and maintained systems. The scope enumeration and this outline area mirror each other, and candidates should study them together — equipment that appears in the rule’s list is equipment the sitting can ask about as a working system.

Refrigerants and Refrigeration — 15

Refrigeration theory and practice, supported in the room by Modern Refrigeration and Air Conditioning (19th or 20th edition) and the Pressure and Enthalpy Charts whose preprinted title the bulletin requires. The charts requirement is a tell: chart-based reasoning is expected, not optional, and candidates should arrive fluent in reading them rather than hoping to learn the layout during the sitting.

Piping — 10

The smallest area is still a tenth of the paper, drawing on IPT’s Pipe Trades Handbook and the Uniform Plumbing Code 2021 in the reference set. Its weight invites a specific error — deferring piping preparation because the area is smallest — that costs more than it saves, because 10 questions is larger than the margin by which most sittings are decided.

The sitting itself

The trade examination is delivered by PSI as an open-book, computer-based sitting of 100 questions in 245 minutes, with scores reported immediately. Open book does not mean open shelf: candidates bring their own references from the allowed list, bound, highlighted, underlined and indexed beforehand if they wish, but never written in — a reference found written in is confiscated and the candidate is reported to the Department. Permanent tabs only; temporary tabs must be removed; no additional papers, loose or attached. A silent, non-printing, non-programmable calculator is allowed, as is the duct calculator noted above. For code questions, the examination is based only on the listed code edition.

The administration rules carry their own penalties. Arrive at least 30 minutes early. Cancellation or rescheduling without forfeiting the fee requires notice 2 days before the appointment, and voicemail or email is not an acceptable cancellation. Retakes are capped: the same examination not more than twice within a 30-day period, and after two failures inside 30 days the wait runs 30 days from the first attempt. No pretest or unscored count is published for this examination; candidates pacing themselves by a rumoured total are pacing by a number PSI does not publish.

The code layer in depth: agreement, and one stale label

New Mexico’s code position is unusually clean, and the guide states both layers separately because candidates must hold them separately even when they agree. The examination layer keys the Uniform Mechanical Code, 2021. The field layer is the 2021 New Mexico Mechanical Code at 14.9.2 NMAC, which adopts the 2021 UMC as amended by CID, amended effective March 10, 2022. Tested equals adopted: UMC 2021 in both directions.

Two traps sit inside that agreement. The first is the bulletin’s own reference list, which prints the New Mexico Mechanical Code line with the prior edition’s label. The label is stale; the current rule is the 2021 code, and no candidate should conclude from the printed label that an earlier edition governs field work. The second trap is imported material: New Mexico is a UMC state, and the International Mechanical Code is a different family’s book. Provisions that exist only in the IMC — its access and passageway rules are the standard example — are not New Mexico content, and preparation built on IMC material must be re-keyed to the UMC before it can be trusted here. A draft proposal for a later New Mexico mechanical code exists in the rulemaking record but has not been adopted; it changes nothing in either layer and candidates should not study toward it.

The full allowed-reference list for MM-3, as printed, is: Uniform Mechanical Code, 2021; Modern Refrigeration and Air Conditioning, 19th or 20th edition; IPT’s Pipe Trades Handbook (2016); Uniform Plumbing Code, 2021; New Mexico Plumbing Code (NMAC 14.8.2), 2015; New Mexico Mechanical Code (NMAC 14.9.2), as discussed above; SMACNA HVAC Duct Construction Standards, 2005, 3rd edition; Pressure and Enthalpy Charts; and Sheet Metal (ATP, 2006).

Eligibility in depth: the qualifying party’s record

The experience gate is four years (8,000 hours) within the 10 years immediately prior to application, related to the classification, stated identically in the rule at 14.6.6.11, the PSI experience-verification form and the qualifying-party provisions at 14.6.3.8G(2)(a). Accredited technical training counts in lieu of work experience at one-half year per year of training and may never exceed one-half of the total requirement — so training can carry a candidate halfway to the gate, never through it.

The qualifying-party mechanics repay slow reading, because the certificate is personal and perishable. It issues only to an individual 18 or older, is not transferable, and authorises work only while attached to a valid license. A QP certificate that does not qualify a valid license within 12 months of the examination score report automatically expires. A QP who does not qualify a valid license for any consecutive two-year period loses eligibility and must re-apply, retest and repay the examination fee — with one relief: the director may waive the examination for 12 more months on documented equivalent experience during that period. A QP may qualify more than one entity, other than a joint venture, only where the entities share at least 30% common ownership.

Loss of a QP is the system’s stress case, and the rule choreographs it. Both parties must notify CID in writing within 30 days of the loss, as for any change of address. The license is automatically cancelled; work in progress may continue for not more than 120 days, after which permits cancel and further work is unlicensed activity. Where the loss is through no fault of the licensee and suspends the license, a trade member with five or more years’ employment by that licensee may be issued a temporary QP certificate without examination under NMSA 60-13-16D, and must pass the regular examination within 90 days of its issuance.

Integrity and character provisions complete the record. A determination of cheating voids the examination, forfeits all fees, automatically voids any license or certificate issued on that examination, and bars the applicant from any CID examination for one year. The disqualifying felonies at 14.6.3.8F(4) include attempts to evade tax; crimes involving physical harm, or attempt, conspiracy or solicitation to commit them; robbery, larceny, burglary, fraud, forgery, embezzlement, arson, identity theft, extortion, racketeering and receiving stolen property; and bribery of a public officer or employee. Sealed, dismissed, expunged or pardoned convictions, juvenile adjudications, and convictions outside the list may not be used. The bureau chief may waive the state-specific written trade examination for a QP who passed the NASCLA accredited examination at the passing score and meets all other QP requirements — the trade examination only, never business-and-law or experience. Military members and veterans receive an expedited route: issuance as soon as practicable and no later than 30 days after a completed application, and no license or certificate fee for the first three years.

Fees, bond and renewal in depth

The dollars separate into three instruments, and the guide keeps them separate because the sources do. PSI charges the examination fees: $68.88 for the Business and Law examination, required of all first-time candidates, and $68.88 for each trade examination, at the same figure for retakes. Totals that secondary sources attribute to holding a license through PSI are PSI-charged figures in that vendor layer; the CID rule does not set them, and they are not restated here as rule fees. CID charges the licensing fees at 14.5.5 NMAC: a $30.00 non-refundable application fee for an initial license and for each additional classification; a basic license fee for MM-3 of $50.00 per year or $100.00 for two years, per classification; a $6.00 certificate of qualification fee including gross receipts tax; $6.00 for each replacement certificate, license or wallet card; examination-review fees of $25.00 per review in the categories the rule names and $40.00 per special review after failing an examination twice in any classification; and authority to raise examination fees by a commission-approved multiplier of up to three. The application fee and the certificate fee are separate instruments — any source presenting them as one combined figure has merged what the rule keeps apart. Photocopies and certified copies carry their own small per-page charges in the same rule.

The bond is a licensure instrument, not a fee: $10,000, corporate surety, underwritten by a surety authorised in New Mexico, effective dates covering the entire period of licensure, required at initial licensure and as a condition of renewal. Its money is purpose-bound — it pays only to cure CID-certified code violations the licensee caused and did not correct — and time-bound: claims within two years after final inspection or issuance of a certificate of occupancy, whichever is earlier. The surety must give CID and the licensee 30 days’ prior written notice of intent to cancel, and failure to furnish a replacement bond brings immediate action for cancellation of the license.

Renewal at 14.6.3.8I is administrative, not educational. CID or its designee mails the renewal form at least 30 days before expiration, but the duty to renew on time is the licensee’s alone whether or not the form arrives; the filing date is the postmark or the hand-delivery receipt date; the form must bear the signatures of all current qualifying parties; and the bond must be maintained. An untimely or non-compliant renewal leaves the license suspended and subject to cancellation under §60-13-18. The renewal provisions require no coursework: contractor licenses and QP certificates carry no continuing-education requirement. The rule states no fixed contractor license-term length, and none is stated here.

A study plan built on the outline’s own weights

First, the three 20-question areas as a block. Sixty questions — controls and low-voltage wiring, duct work and ventilation, general knowledge — decide most sittings. Study them interleaved, not in sequence, because the sitting interleaves them. Second, the code as a working tool. UMC 2021 fluency under open-book conditions means retrieval speed: tabbed (permanently), indexed, and practised against the clock, with the discipline that nothing may be written in the book. Third, the chart and wheel skills. Pressure-enthalpy chart reading and ductulator work are performance skills; drill them as performances, timed, until the mechanics disappear. Fourth, the New Mexico layer as its own subject. The scope line’s two limits, the QP clocks, the fee layers and the boundary classifications are short, exact material that generic HVAC preparation does not contain — and the sitting’s state-specific items are drawn from exactly there. Fifth, mixed timed practice across all six areas together, scored by area, so the final week can be aimed at the weakest area rather than the most familiar one.

The errors this examination is built to catch

Treating the 24-volt line as guidance. It is a scope limit; work above it is outside the classification. Extending water work past existing valved outlets. The grant stops at the valve. Studying the IMC for a UMC sitting. The codes are different books; only UMC 2021 is keyed. Trusting the bulletin’s stale label for the state mechanical code line over the current rule at 14.9.2. Merging the fee layers — PSI’s examination charges, CID’s licensing fees and the bond are three instruments, and items that test them test the separation. Assuming a coursework duty at renewal for the contractor tier; none exists in the renewal rule. Letting the clocks lapse — six months to test after eligibility, one year to match the two passes, one year of score validity — each expiry is a restart, not an extension.

Frequently asked questions

What is the difference between the program page and this guide?

The program page states the verified position compactly. This guide works through the same record in depth — the scope line read closely, each outline area, the qualifying-party mechanics, and the fee, bond and renewal instruments. Both describe the same program: New Mexico MM-3 Heating, Ventilation & A/C Exam Preparation.

Why does the guide keep returning to the qualifying party?

Because the license is held through the QP. The QP sits the examinations, the certificate expires if it does not qualify a valid license within 12 months of the score report, and the license itself is automatically cancelled when the QP is lost. The examination is one event inside that longer relationship.

Is the Business and Law examination covered by this program?

The program prepares candidates for the MM-3 trade examination. The Business and Law examination is a required companion step — the two passes must fall within 1 year of each other, or an approved Business and Law course may be completed in its place — and it is described in this guide for structure only.

Which references may be taken into the room?

Only the allowed list printed for MM-3: UMC 2021, Modern Refrigeration and Air Conditioning (19th or 20th edition), IPT’s Pipe Trades Handbook (2016), UPC 2021, the New Mexico Plumbing Code (14.8.2), 2015, the New Mexico Mechanical Code (14.9.2), SMACNA HVAC Duct Construction Standards (2005, 3rd edition), Pressure and Enthalpy Charts, and Sheet Metal (ATP, 2006) — bound, permanently tabbed, and never written in.

What happens if a candidate fails?

Scores are reported immediately. The same examination may be taken not more than twice within a 30-day period; after two failures inside 30 days, the wait runs 30 days from the first attempt. CID charges the review fees recorded in this guide for examination reviews in the categories the rule names.

Does the examination include a hands-on component?

The sources behind this guide describe the PSI written examinations recorded here and state no hands-on component; this guide states neither its presence nor a verified absence.

How is experience documented?

Through the experience-verification process: four years (8,000 hours) within the last 10 years, related to the classification, with accredited training credited at one-half year per year of training up to one-half of the requirement.

Can examination results from another state substitute?

Only through the narrow NASCLA route: the bureau chief may waive the state-specific written trade examination for a qualifying party who passed the NASCLA accredited examination at the passing score and meets all other requirements. Business-and-law and experience requirements are never waived by that route.

When does enrollment open for the PassProfessor program?

The program is in the works and enrollment is not yet open. Leave an email address on this page to be notified when it is ready.