Michigan HVAC Sample Practice Questions
This page republishes, in full and in serve order, the free 20-question sample served by the PassProfessor Michigan HVAC program (quiz hvac-mi-sample-quiz). The sample is a standalone free offer — no enrollment is needed to take it, and it is available before any purchase decision. Its 20 questions span 16 of the program’s 18 topic areas, and every answer is explained. The sample sits outside the program’s worked-question cap. You can also take the sample as a timed quiz.
Question 1 — Refrigeration Principles & Components
How does a digital scroll compressor vary its capacity during a control cycle?
- It reverses the direction of the orbiting scroll for part of each cycle so compressed gas flows backward through the discharge port toward the suction side
- It briefly separates the scrolls so compression stops for part of the cycle
- It varies the voltage and frequency supplied to the motor so shaft speed changes continuously in direct proportion to the cooling load on the building
- It opens and closes a hot-gas bypass valve in the discharge line while the scrolls themselves remain loaded and compressing at full displacement continuously
Correct: B — It briefly separates the scrolls so compression stops for part of the cycle
A digital scroll uses a solenoid to axially separate the scrolls for timed intervals, so average capacity follows the loaded fraction of the cycle at constant speed. It does not reverse rotation, it is not a variable-frequency speed control, and its scrolls themselves unload rather than relying on a discharge hot-gas bypass.
Reference: Compressor manufacturer service guidance; Modern Refrigeration and Air Conditioning
Question 2 — Controls & Electrical for HVAC
What is the purpose of a heat anticipator in a traditional electromechanical thermostat?
- To open the heating contacts slightly early to prevent temperature overshoot from residual heat
- To increase the furnace firing rate automatically whenever outdoor temperature falls below a set balance point during cold weather
- To delay the blower until the heat exchanger is fully hot
- To add resistance so the thermostat can operate without a common wire
Correct: A — To open the heating contacts slightly early to prevent temperature overshoot from residual heat
The anticipator warms the sensing element so contacts open before residual heat overshoots the setpoint, which is correct. Increasing firing rate is a burner control function, not the anticipator. Blower delay is handled by a fan control or board timing, not the anticipator. Operating without a common wire relates to power-stealing or batteries, not anticipation.
Reference: Manufacturer installation and service literature for HVAC controls
Question 3 — Safety, Testing & Code Practice
An appliance in an attic is reached through a small scuttle with no walkway and no lighting. Which condition must be corrected?
- Move the appliance disconnect to the living room so the technician never needs to enter the attic for any service operation
- Provide a safe passageway, a service platform where required, lighting, and a receptacle at the appliance.
- Require the homeowner to supply a flashlight and a loose sheet of plywood each time a technician visits the property
- Enlarge the scuttle only if the appliance is replaced, because access rules apply solely on the day of original installation
Correct: B — Provide a safe passageway, a service platform where required, lighting, and a receptacle at the appliance.
Technicians must be able to reach and service the appliance safely, with passage, platform, light, and power. A remote disconnect does not make the attic workable, borrowed plywood and flashlights are not permanent access, and access requirements are not waived between replacements.
Reference: IMC mechanical provisions; IFGC fuel gas provisions
Question 4 — Packaged & Manufactured Systems
After replacing a rooftop blower belt, how should correct tension be judged before returning the unit to service?
- By twisting the belt a full half-turn at mid-span, with any belt that resists twisting considered correctly tensioned for service
- By running the blower for one hour and retightening only if the belt has stretched until it touches the guard at the bottom of its travel
- By pressing the belt until it feels as tight as a guitar string, because tighter tension always improves airflow and bearing life together
- By measuring deflection at mid-span under the specified force and comparing it with the unit or belt maker's deflection specification
Correct: D — By measuring deflection at mid-span under the specified force and comparing it with the unit or belt maker's deflection specification
Belt tension is set by measured deflection under a specified force at mid-span, compared with the published specification. Twist feel is not a measurement, waiting for visible stretch leaves the unit running loose, and over-tightening overloads bearings and shafts rather than improving service life.
Reference: Manufacturer packaged-unit service guidance; ASHRAE ventilation and economizer practice; International Mechanical Code general practice
Question 5 — Heating Systems
What does a low-water cutoff protect a boiler against?
- High gas pressure at the manifold caused by a failed regulator that is delivering full inlet pressure directly to the burners
- Frozen coils in the air handler
- Excessive circulator speed
- Firing or overheating when boiler water level falls too low, which can damage the boiler and create a hazard
Correct: D — Firing or overheating when boiler water level falls too low, which can damage the boiler and create a hazard
The low-water cutoff interrupts burner operation when water level is unsafe, preventing dry-firing damage and hazard, option D. Gas manifold pressure (A) is governed by the regulator and gas valve, frozen air-handler coils (B) concern a different system, and circulator speed (C) is set by the pump and its controls, not a water-level safety.
Reference: Modern Refrigeration and Air Conditioning
Question 6 — Refrigerants, Recovery & Handling
How do mainstream equipment standards treat installing R-454B into an existing air conditioner that was designed and listed only for R-410A?
- Not permitted; the equipment must be designed and listed for the mildly flammable refrigerant it will contain
- Permitted as a routine retrofit whenever the pressures are similar, provided the oil is changed and the nameplate is updated by the installing contractor
- Permitted only in commercial buildings, because occupancy rules rather than equipment listing determine whether a different refrigerant may be used
- Permitted if the charge is reduced by a small percentage, because a reduced charge converts an unlisted refrigerant change into an approved application
Correct: A — Not permitted; the equipment must be designed and listed for the mildly flammable refrigerant it will contain
Equipment must be designed and listed for the mildly flammable refrigerant, including its sensors, controls, and electrical components. Similar pressures do not create a retrofit approval, building type does not override equipment listing, and trimming the charge does not make an unlisted conversion acceptable.
Reference: ASHRAE Standard 15 safety practice; UL 60335-2-40 equipment safety concepts; EPA Section 608 refrigerant handling rules
Question 7 — Air Distribution, Duct Design & Airflow
Instead of bypassing to the return, a designer relieves excess air into a hallway and basement area that tolerate extra conditioning. What is this strategy called, and what is its main trade-off?
- A dump zone; the relieved area may be overconditioned while it absorbs excess air
- A dead zone; the relieved area receives no air at all, and the trade-off is that the excess blower airflow is absorbed by raising static pressure in the trunk instead
- A purge zone; the relieved area is ventilated outdoors, and the trade-off is the energy cost of discarding conditioned air through an exterior wall opening on every cycle
- A staging zone; the relieved area is heated by a separate appliance, and the trade-off is the fuel cost of running two heat sources whenever only one thermostat is calling
Correct: A — A dump zone; the relieved area may be overconditioned while it absorbs excess air
A dump zone gives excess supply air a harmless destination instead of short-circuiting it into the return, at the cost of overconditioning that tolerant area. The other descriptions send the air nowhere, outdoors, or to a second appliance, none of which describes relieving air into a non-critical conditioned area.
Reference: ACCA Manual D concepts; Manufacturer zone panel guidance
Question 8 — Ventilation, Venting, Combustion Air & IAQ
In a hot-humid climate, a vented crawlspace gets wetter in summer the more its vents are opened, and ducts there sweat heavily. Why does ventilation worsen it?
- Vent air adds moisture that condenses
- Opening vents raises crawlspace temperature above the dew point of the outdoor air, which forces moisture out of the soil and into the framing
- Wind through the vents pressurizes the crawlspace and squeezes liquid water out of the soil through the foundation walls into the space
- The vents admit insects whose activity generates the extra moisture, and the duct sweating is a separate refrigerant-side problem
Correct: A — Vent air adds moisture that condenses
Humid outdoor air entering the crawlspace contacts ducts and framing cooled by the house above, falls below its dew point, and deposits moisture, so more ventilation means more condensation. Ventilation does not heat surfaces above dew point in a way that draws water from soil, wind pressure does not squeeze liquid water through foundation walls, and insects do not generate this volume of moisture.
Reference: Building Science Corporation guidance; ASHRAE Handbook — Fundamentals
Question 9 — Equipment Installation & Commissioning
To use the target-superheat charging method on a fixed-orifice system, which two air temperatures must the technician measure at the time of charging?
- Supply-air dry bulb and return-air dry bulb
- Liquid-line temperature and suction-line temperature only, measured at the service ports with the system running and stabilized under a steady indoor load
- Compressor discharge temperature and outdoor wet bulb
- Indoor wet-bulb temperature at the return and outdoor dry-bulb temperature at the condenser
Correct: D — Indoor wet-bulb temperature at the return and outdoor dry-bulb temperature at the condenser
The target-superheat chart or formula is entered with indoor wet bulb, which reflects indoor load and humidity, and outdoor dry bulb, which reflects condensing conditions. Option A gives temperature split, not the chart inputs, option B is used to compute actual superheat rather than the target, and option C pairs a refrigerant temperature with the wrong outdoor measurement.
Reference: Manufacturer service and installation literature
Question 10 — Business & Law Practice
A typical contractor workmanship warranty differs from a manufacturer's equipment warranty in which way?
- The workmanship warranty covers the contractor's installation work; the manufacturer's covers its equipment defects
- The workmanship warranty covers the factory's equipment defects, while the manufacturer covers the contractor's labor errors
- Both warranties are identical in coverage, and the distinction exists only for marketing purposes in the proposal
- The manufacturer's warranty covers the contractor's installation workmanship for as long as the building remains standing
Correct: A — The workmanship warranty covers the contractor's installation work; the manufacturer's covers its equipment defects
A is correct because the contractor warrants its own installation work while the manufacturer warrants defects in its equipment. B is incorrect because it reverses the two parties' responsibilities. C is incorrect because the coverage, responsible party, and claim route genuinely differ. D is incorrect because a manufacturer does not warrant the installing contractor's workmanship.
Reference: NASCLA Contractors Guide to Business, Law and Project Management (general concepts)
Question 11 — Refrigeration Principles & Components
Hot-gas bypass gas is introduced directly into the suction line far from the evaporator on a system that then logs oil in the evaporator during long bypass hours. Why can the injection point matter?
- Bypass into the distributor or evaporator inlet keeps refrigerant velocity through the coil up, helping oil return, while suction-only injection can leave coil velocity too low
- The injection point never matters, because hot gas entering anywhere in the low side produces identical evaporator velocities and identical oil-return behavior at all loads
- Injecting into the suction line raises evaporator velocity the most, because the gas passes through the entire coil twice before it reaches the compressor inlet
- Injecting at the distributor stops all oil movement in the coil, because the added gas pressure holds the oil stationary against the tube walls during bypass operation
Correct: A — Bypass into the distributor or evaporator inlet keeps refrigerant velocity through the coil up, helping oil return, while suction-only injection can leave coil velocity too low
Feeding bypass gas through the coil maintains mass flow and velocity that sweep oil back, whereas suction-line-only injection satisfies the compressor while the coil itself sees very low flow and can log oil. Injection location changes coil velocity and oil behavior materially, suction-only gas does not pass through the coil at all, and distributor injection promotes rather than prevents oil movement through the coil.
Reference: Refrigeration component manufacturer guidance; ASHRAE refrigeration practice
Question 12 — Heating Systems
On a new condensing furnace, the PVC exhaust vent runs 18 feet horizontally to the sidewall. How should that horizontal run be pitched, and why?
- Pitched away from the furnace so condensate runs outdoors, where it can drip freely off the termination fitting
- Pitched back toward the furnace
- Pitched exactly level so condensate can sit in the pipe and evaporate slowly during the off cycle between calls for heat
- Pitched away from the furnace on the first half and back toward it on the second half, forming a shallow low point in the middle
Correct: B — Pitched back toward the furnace
The exhaust is pitched back toward the furnace, typically about 1/4 inch per foot, so condensate formed in the vent drains to the furnace drain system. Option A sends acidic condensate outdoors to drip and freeze at the termination, option C lets water pool and block vent area, and option D creates a trap in the middle that can fill and trip the pressure switch.
Reference: Manufacturer installation instructions; Fuel gas and venting installation practice references
Question 13 — Cooling Systems: Service, Diagnostics & Repair
A 5-ton system serves a 1,250 sq ft home whose calculated load is 2 tons. It satisfies the thermostat in 6-minute cycles, indoor humidity sits at 68%, supply air is cold, and all pressures, superheat, subcooling, and airflow per ton are normal. Occupants complain the home feels clammy. What is the correct diagnosis?
- Oversized equipment short-cycling
- A blower speed set far too low, which would lengthen runtimes and wring out more moisture, the opposite of the 6-minute cycles observed
- A dirty evaporator coil reducing dehumidification, which would distort airflow and superheat readings that here are entirely normal
- Low refrigerant charge causing poor latent removal, which is contradicted by the normal superheat, subcooling, and pressures measured on this call
Correct: A — Oversized equipment short-cycling
Normal refrigerant readings with very short cycles and high indoor humidity are the signature of gross oversizing: sensible load is met before the coil runs long enough to remove latent load. Charge, blower speed, and coil condition all show normal measurements, and low blower speed would extend runtime rather than shorten it.
Reference: ASHRAE Handbook — Refrigeration; EPA Section 608 Study Guide; Manufacturer Service and Diagnostic Literature
Question 14 — Piping, Brazing & Gas Piping
A masonry chimney is relined for a mid-efficiency furnace. A liner much larger than the vent connector is proposed to 'give the gases room.' The main risk is:
- Excessive draft that pulls too much dilution air through the draft hood and raises the appliance firing rate above its nameplate input
- Flue gases moving so fast in the large liner that they cannot transfer heat and instead melt the liner joints within one heating season
- A pressure increase inside the chimney that forces the furnace pressure switch to stay closed after the inducer has shut down
- Slow, cool flue gases with weak draft and condensation
Correct: D — Slow, cool flue gases with weak draft and condensation
Slow, cool flue gases with weak draft and condensation. A large liner does not raise firing rate or flue-gas speed, and it does not create pressure that holds a pressure switch closed.
Reference: IFGC gas piping and venting provisions; NFPA 54 National Fuel Gas Code; Manufacturer service and installation literature
Question 15 — Commercial Refrigeration Systems
An ice machine makes thin, weak ice and cycles off on high head pressure on warm afternoons. Its air-cooled condenser is packed with grease and dust. The best first action is:
- Increase the ice thickness setting to compensate
- Shorten the harvest cycle
- Add water to the sump until the pump overflows
- Thoroughly clean the condenser and verify airflow, then recheck pressures and production
Correct: D — Thoroughly clean the condenser and verify airflow, then recheck pressures and production
A fouled air-cooled condenser cannot reject heat, so head pressure rises and freeze efficiency falls; cleaning restores heat transfer before judging other parts. Thicker settings in option A lengthen an already stressed cycle, option B changes harvest rather than heat rejection, and option C overfills the water system without addressing pressure.
Reference: Modern Refrigeration and Air Conditioning; ASHRAE refrigeration practice
Question 16 — Michigan Licensing Law & Rules
A license was not renewed and became void after the October 31, 2028 deadline. The former licensee files a reinstatement application in 2030. Which determination is correct?
- Reinstatement requires passing the examination again, since any voided license must be re-earned
- Reinstatement in 2030 is within 3 years after voiding, so reexamination is not required, and until reinstated the void license cannot be used to obtain a permit
- Reinstatement in 2030 is within 3 years after voiding, so the license was never void for permit purposes, and the former licensee may obtain permits while the reinstatement application is being processed
- Reinstatement is impossible after a license becomes void, and a new application is the only route
Correct: B — Reinstatement in 2030 is within 3 years after voiding, so reexamination is not required, and until reinstated the void license cannot be used to obtain a permit
A license not renewed is void for the purpose of obtaining a permit, and a reinstatement filed within 3 years after voiding, as a 2030 filing is after the 2028 voiding, does not require reexamination. A filing after that 3-year period, such as in 2032, would require meeting the examination requirement.
Reference: mi-facts fact 58; MCL 339.5813(2); R 339.5118
Question 17 — Air Distribution, Duct Design & Airflow
Total external static pressure on a PSC-blower system rises from 0.50 in. w.c. to 0.74 in. w.c. over a season, filter pressure drop accounts for most of the increase, and rooms are getting less air. What is happening?
- Airflow falls as static rises
- The blower is delivering more air than before, because a PSC motor speeds up automatically to overcome added resistance and maintain its original operating point
- The refrigerant charge is migrating to the filter, which raises its pressure drop and reduces airflow by starving the evaporator coil of refrigerant flow
- The ducts are leaking less than when new, so the higher static pressure is simply proof that sealing work has succeeded and airflow should be unchanged
Correct: A — Airflow falls as static rises
A loaded filter adds resistance; on a PSC blower the operating point moves to higher static and lower airflow, which matches the comfort complaint. A PSC motor does not speed up to compensate, refrigerant does not migrate into an air filter, and reduced duct leakage would not selectively raise the filter's share of pressure drop.
Reference: ACCA Manual D; Residential duct testing practice
Question 18 — Heating Systems
No-heat call. A furnace completes prepurge, proves its pressure switch, and glows its igniter on every trial, but the burners never light and no gas smell is present. A meter shows 24 V delivered to the gas valve terminals during the trial, manifold pressure reads zero, and the gas valve coil measures open circuit against a specified resistance in the tens of ohms. Inlet gas pressure is normal. What is the most likely cause?
- An open gas valve coil
- A failed igniter that never reaches lighting temperature, ruled out because the igniter glows visibly on every trial and the failure includes zero manifold pressure with full valve voltage
- A control board that never calls for gas, ruled out because 24 V is measured at the gas valve terminals during the ignition trial window
- A closed manual gas cock starving the valve, ruled out because inlet pressure at the valve measures normal while the manifold side stays at zero
Correct: A — An open gas valve coil
Voltage arrives, inlet pressure is normal, and the coil is electrically open, so the valve can never open and manifold pressure stays at zero despite a glowing igniter. The igniter performs, the board delivers its call, and gas reaches the valve inlet, leaving the open coil as the single failed link in the sequence.
Reference: Manufacturer service and diagnostic literature; Residential gas furnace service practice
Question 19 — Load Calculation & System Design
A designer's worksheet shows: blower maximum external static 0.70 in. w.g.; available for ducts listed as 0.70; friction rate computed from 0.70 over a TEL of 200 feet, giving 0.35 in. per 100 feet. The selected coil drops 0.30 and the filter 0.15. Identify the design error and its consequence.
- The designer spent the blower's whole budget on the ducts without subtracting the coil and filter; only 0.25 in. is truly available, so the correct friction rate is 0.125 in. per 100 feet and the ducts as sized will be far too small, producing high static and low delivered airflow
- There is no error, because coil and filter drops are paid from a separate budget
- The only error is arithmetic: 0.70 over 200 feet gives 0.70 per 100 feet
- The consequence will be oversized ducts and excessive airflow at the registers
Correct: A — The designer spent the blower's whole budget on the ducts without subtracting the coil and filter; only 0.25 in. is truly available, so the correct friction rate is 0.125 in. per 100 feet and the ducts as sized will be far too small, producing high static and low delivered airflow
Available static for ducts is what remains after non-duct components are subtracted: 0.70 – 0.30 – 0.15 = 0.25 in., and 0.25 x 100 / 200 = 0.125 in. per 100 feet — the as-designed rate is nearly three times too high. Option B is wrong because coil and filter are external components drawing on the same single blower budget — there is no second budget; option C is wrong because the arithmetic (0.70 x 100 / 200 = 0.35) is internally consistent; the flaw is the 0.70 input, not the division; option D is wrong because an inflated friction rate sizes ducts too small, which restricts airflow rather than increasing it.
Reference: ACCA Manual D
Question 20 — Trade Application
An appliance's vent operates under positive pressure, yet its vent gases leave hot enough that they do not condense in the vent. Which venting category is it?
- It is a Category III appliance with positive vent pressure and noncondensing gases
- It is a Category I appliance with a fan-assisted burner and a draft hood fitted
- It is a Category II appliance venting by nonpositive pressure through the vent
- It is a Category IV appliance whose condensate must be drained from the vent run at every stage of normal equipment operation outdoors
Correct: A — It is a Category III appliance with positive vent pressure and noncondensing gases
Positive vent pressure combined with noncondensing vent gases is the definition of Category III. Category I and II both operate nonpositive, and Category IV is the condensing positive-pressure category.
Reference: mi-facts fact 39; edition-stable trade principle (F2 fence)
The full program carries 1,450 practice questions across all 18 topic areas: Michigan HVAC Exam Prep · 42 worked questions · Michigan HVAC Exam Guide.
Disclaimer
PassProfessor is an independent exam-preparation provider. This program is exam preparation only: it is not the real exam, it provides no education credit, and completing it does not by itself qualify you for any license or certification. The real exam is run by its own exam body — you register for it, pay its fees, and sit it through that body, not through PassProfessor. All practice questions in this program are written by PassProfessor; they are not actual exam questions.