Maryland’s Master HVACR license is issued by the State Board of Heating, Ventilation, Air-Conditioning, and Refrigeration Contractors, in the Maryland Department of Labor, under Title 9A of the Business Regulation Article. The examination, administered by PSI, is an open-book sitting of 100 questions in 240 minutes, passed at a 70% minimum passing score, keyed to the International Mechanical Code, 2018 edition only, while the field code points to the 2021 edition. This guide works through the credential, the outline, and the ladder in full.
This program is part of the expanding PassProfessor catalog — join the notify list and we’ll email you when enrollment opens.
The credential at a glance
| Item | Verified position |
|---|---|
| Program | Maryland Master HVACR: the Master HVACR Contractor examination for the master license |
| Regulator | State Board of Heating, Ventilation, Air-Conditioning, and Refrigeration Contractors, Maryland Department of Labor, Division of Occupational and Professional Licensing |
| Law and rules | Business Regulation Article, Title 9A; COMAR 09.15 (fees, general regulations, and the Board’s code chapter) |
| Examination vendor | PSI Services LLC, under contract with the Board; applications and eligibility screening run through PSI |
| Examination format | Computer-administered by appointment; 100 questions; 240 minutes; open book |
| Passing standard | 70% minimum passing score, in the bulletin’s published outline form |
| Tested references | International Mechanical Code, 2018 edition only (effective May 15, 2025); Modern Refrigeration and Air Conditioning, 21st or 22nd edition; Manual J, 2006 eighth edition; the listed federal safety volume; the ACCA Ductulator |
| Field code position | Most recent mechanical code as incorporated in the Model Performance Code — currently the 2021 edition — with local adoption and enforcement layers |
| Credential term | Two-year term to the first October 1 in an odd-numbered year; no education duty for licensees |
| Administrator note | PassProfessor is independent and is not affiliated with the State Board of HVACR Contractors or with PSI |
This guide is the companion to the Maryland Master HVACR program page at /maryland-master-hvacr-exam-prep/. The program page states the position briefly; this guide states it in full, and its organisation follows Maryland’s own structure: the ladder first, then the sitting, then the two code layers that must never be merged.
The ladder in full: six classes, one individual license
Title 9A licenses exactly six classes: master, master restricted, limited, journeyman, journeyman restricted, and apprentice. The Board sits in the Department of Labor, with nine members — five master HVACR contractors, a master electrician, a master plumber, and two consumer members, on staggered three-year terms. The general rule is unqualified: an individual shall be licensed by the Board before the individual provides or assists in providing HVACR services in the State. The statute’s service definition — installing, maintaining, altering, remodeling, or repairing heating, cooling, refrigeration, ventilation, or hydronic systems — is given working edges by its defined terms, of which two repay memorisation: a refrigeration system cools a surface or area below 55 degrees Fahrenheit, and a ventilation system moves air at more than 250 cubic feet per minute. Title 9A creates no business license. The business acts through the licensee it employs and designates to direct and control its services, whose name and license number must appear in its advertisements, and a licensee may use the license for a permit only when familiar with the work’s design and purpose, available to direct and control everyone on it, and responsible for it.
The classes divide by function and contracting power. The master provides services across all areas and may contract. The master restricted licensee works in restricted areas — forced air heating, hydronic heating, ventilation, air conditioning, and refrigeration in the statute’s framing — which the vendor examines as separate specialty sittings, adding a combined heating category operationally. The journeyman restricted license mirrors those areas one tier down. The limited license is exclusively to maintain or repair: a contractor-tier license that may not be used for installations or retrofits. The journeyman works under a licensed contractor and may not contract independently. The apprentice assists while in training; entry to the trade requires the apprentice license, with no prerequisites.
Examination is the default route for every class above apprentice, in the bulletin’s own framing: individuals who desire licensure as journeyman restricted, journeyman, limited, master restricted, or master must first pass an examination. The Board determines the subjects, scope, form, and passing score of its examinations, and restricted and limited applicants are examined only on the subjects in which they have the experience their gates require. The sections that follow take the Master sitting first and the gates second, because in the current process the candidate meets the vendor before the license, and meets the gates inside the vendor’s application.
The Master sitting in full
The Master HVACR Contractor examination is a computer-administered, open-book sitting by appointment: 100 questions, 240 minutes, a 70% minimum passing score in the bulletin’s published outline form — the score-reporting layer states a passing grade of 70 points, and the statute states a grade of at least 70 percent, three published forms of one standard — and a vendor examination fee of $150. No pretest or unscored count for this or any Maryland HVACR examination appears in the sources for this guide, and none is stated. The outline divides the 100 questions into six blocks. Refrigeration and Air Conditioning, 25: theory; refrigerants; equipment sizing and design; equipment and components; equipment installation; and system operation, troubleshooting, and maintenance. Electrical Knowledge, Motors, and Controls, 20: alternating and direct current circuits, electric motors, and controls. Heating Systems, 20: heating theory and types; combustion air; equipment sizing; heating equipment; equipment installation; system operation, troubleshooting, and maintenance; steam, hydronics, and hydronic piping; vents and chimneys; and fuel oil systems. Piping, 15: blueprints and schematics; materials, applications, and general installation requirements; joints and connections; hangers and supports; valves and fittings; testing and troubleshooting; and piping insulation. Air Distribution Systems, 15: duct definitions, sizing, and design; duct assembly and installation; hangers and supports; duct materials and shapes; duct insulation; fire and smoke control; hoods and exhaust systems; testing and balancing; ventilation requirements; and plans and symbols. Safety, 5: scaffolds through other safety devices, including safety data, fall protection, trenches and excavations, contractor responsibilities, and ladders. The blocks sum to 100, and a study plan allocated in those proportions — a quarter of the sitting on refrigeration and air conditioning, a fifth each on electrical and on heating — matches the sitting the candidate will actually meet.
The reference list is five items, printed here complete: the International Mechanical Code, listed in the bulletin in several editions and, effective May 15, 2025, the 2018 edition only; Modern Refrigeration and Air Conditioning, 21st or 22nd edition; Manual J — Residential Load Calculation, 2006, eighth edition; the federal workplace safety provisions the bulletin lists, with latest available amendments, or the vendor’s selections from them; and the ACCA Ductulator. No Maryland-specific book appears on the list, no fuel gas code appears on the list, and no fuel gas standard appears on the list either — the fuel gas standard found elsewhere in this programme belongs to restricted sittings, as the code section of this guide states. The journeyman examination carries the same distribution, references, and headline figures as the Master. The restricted specialties are sittings of 50 questions in 120 minutes at a $50 vendor fee per specialty, except ventilation, at 40 questions in 90 minutes. The limited examination is 50 questions in 120 minutes at the Master-tier vendor fee, weighted toward electrical content. Those neighbouring figures change nothing about the Master sitting.
Examination day, scoring, and the second chance
The application is the first examination-day fact. Candidates apply online through the vendor’s Maryland channel — mail, fax, and email applications are no longer processed — uploading qualification documentation, and must pay the examination fee with the application or it will not be processed. Allow up to one week for processing. On the day, candidates arrive at least 30 minutes early, register under the legal name on the identification, and present one valid, unexpired, signature- and photo-bearing identification. Calculators are limited to the non-programmable, silent, battery-operated kind without paper-tape printing or an alphabetic keyboard. A hardcover word-to-word translation dictionary is allowed. The tutorial, of up to 15 minutes, does not count against examination time.
The book rules are quoted in substance because candidates lose sittings to them. The examination is open book; candidates may bring reference books; no study guides are allowed; reference books may be indexed and may contain highlighted or underlined text; all materials must be unmarked, not written in, and may not contain additional papers, loose or attached; and the listed references are the only references allowed in the testing room, and will not be provided at the test centre. The acceptable tabs are the two permanent tab products the bulletin names; the removable flag products it names are unacceptable, and if a proctor can remove a tab without ripping the page, the candidate removes the tabs before taking the examination. Scoring is immediate in its indication: the pass or fail result appears on the computer screen at the end of the test, results are confidential to the candidate and the Board, and a failing candidate is given 30 minutes at the end of the examination to review the items missed, at no charge — a structured review window candidates should treat as part of the sitting and use to map their losses by outline block while the sitting is fresh. Passing candidates receive no further notice from the vendor; licensing instructions come directly from the Department. The fee rules are strict and short: cancellation or rescheduling without forfeiting the fee requires notice received two days before the scheduled date — a Monday appointment requires notice by the previous Saturday — voicemail is not an acceptable cancellation, and missing the appointment, cancelling late, arriving too late, or failing to present proper identification forfeits the fee, which is valid for one examination only, is not refundable or transferable, and is valid for 90 days. Retaking runs on three consistent layers: the vendor bars sitting more often than every 30 days, the regulation allows reapplication 30 days after the last sitting on a fresh examination fee, and the statute requires a fresh application and a fresh, nonrefundable fee after a failure or a failure to appear — with the examination-misconduct rule standing behind all of it, under which unauthorised material or other misbehaviour causes immediate rejection of the application and bars reexamination for at least one year. No practical component exists in this programme; every sitting described here is a computer-administered open-book examination.
The code layers in full: 2018 in the room, 2021 in the field, nothing else anywhere
The tested layer is one edition of one code, plus a textbook. Effective May 15, 2025, only the 2018 edition of the International Mechanical Code is used for the Master examination, alongside Modern Refrigeration and Air Conditioning in its two listed editions. The build rule for preparation follows directly: key mechanical study to the 2018 edition and refrigeration study to the listed text, and key nothing to the 2021 edition or to any fuel gas code edition as Maryland examination material. The fuel gas position needs its sentence of precision. No fuel gas code appears in any Maryland HVACR examination. The sole fuel gas text in the entire programme is the national fuel gas standard NFPA 54 in its 2002 edition, and it appears only on the reference lists of the forced air and hydronic restricted examinations — alongside, in those lists, a fuel oil standard and, for hydronic, a hydronic heating text. It is not on the Master list, the journeyman list, the limited list, or the air conditioning, refrigeration, or ventilation restricted lists. NFPA 54 is not a fuel gas code of the international family, and its edition in this programme is 2002; both halves of that sentence protect the candidate from importing the wrong book under the right-sounding name.
The field layer is a pointer, a date, and a set of cautions. The Board’s code chapter, amended effective April 13, 2026, adopts the most recent version of the mechanical code as incorporated in the Model Performance Code, which currently incorporates the 2021 edition. But the pointer does not self-execute: the Model Performance Code may not bind a subdivision unless the subdivision adopts it, enforcement runs through county cooperative agreements, and a county code adopted before January 1, 1988 applies within that county. The Maryland Building Performance Standards adopt neither the mechanical code nor any fuel gas code, so mechanical requirements reach a job through the Board’s code and the local stack. The examination, by contrast, is uniform and dated: 2018, alone, since May 15, 2025. Candidates who keep the two questions separate — what am I tested on, and what governs this job in this county — will not be caught by either layer.
The gates in full: the ladder as the statute states it
The master gate has two elements: experience and examination. The applicant shall have been regularly and principally employed in providing HVACR services, under a journeyman, journeyman restricted, limited, or master restricted license, for not less than three years of active experience under the direction and control of a master HVACR contractor, and shall pass the examination administered by the Board. The master restricted gate mirrors it at three years in its named service areas, under a master or master restricted contractor. The limited gate is two years of active experience providing services under a journeyman license, under the direction and control of a master, master restricted, or limited license holder, plus examination. The journeyman gate — stated here in its statute form, as the licensing requirement, exactly as this package’s programme page states it — requires the applicant to have held, for at least 4 years, an apprentice license, completing during that period at least 6,000 hours of training in providing HVACR services under the direction and control of a licensed contractor, and to pass an examination; the Board’s regulation repeats the same gate as a pre-examination rule, amended effective March 4, 2024, and the Department’s own requirements page states it identically. Candidates will meet a different journeyman figure in the vendor’s bulletin. That figure does not govern: it is the restricted tier’s gate transposed into the journeyman paragraph, it conflicts with the statute, the regulation, and the Department’s page, and preparation or planning built on it understates the journeyman rung by a wide margin. The statute form in this paragraph is the requirement to plan against.
Credits and the one exemption shape timelines. The Board may credit up to three years for comparable formal study, up to six years of qualifying non-conforming experience where the failure is not the applicant’s fault, and shall credit up to three years for teaching formal HVACR courses. The Board shall issue a journeyman license without examination to a completer of an approved apprenticeship programme who applies inside the stated two-year window. The statute’s other without-examination provisions are spent transition provisions, not live routes. Every original applicant must report any conviction with a true-test copy from the court clerk, and concealment may be treated more severely than the conviction itself. After passing, the one-year fuse runs: licensure, with all applicable fees, must be applied for within one year of completing the examination for the results to remain valid.
The dollars in full, in their two instruments
Board fees are set by regulation to approximate the cost of maintaining the Board, are paid to the Comptroller for the occupational mechanical licensing fund, and appear in no current statute text. Under the Board’s current fee schedule, as of January 1, 2025, with original and renewal at the same fee and all fees nonrefundable, the figures are: master, $94.50; master restricted, $31.50 for each area licensed, with no cap on the per-area total printed in the current rule; limited, $94.50; journeyman, $25; journeyman restricted, $25 for each area licensed; apprentice, $12; inspector, $56; letter of good standing, $25; and inactive license, $31.50. Reactivation of an inactive license mid-cycle costs the full license fee for the former category. Vendor fees are a separate instrument, paid directly to the testing service as the regulation itself provides: $150 each for the Master, limited, and journeyman examinations, and $50 for each restricted specialty at either restricted tier. The two layers are never added into a single figure anywhere in this guide, because they are paid to different instruments for different things at different moments — the vendor fee with the examination application, the Board fee at licensure and at each renewal. Older schedules circulate widely: an earlier regulatory schedule at lower figures, and a repealed statutory schedule lower still, both superseded. Candidates budgeting from secondary material should re-derive every dollar from the two lists in this section.
Renewal, standing, and reciprocity
The license expires, unless renewed for a two-year term, on the first October 1 that comes after the license’s effective date and in an odd-numbered year — a fixed statewide calendar under which the whole trade renews together, with a staggered-expiration authority in the statute for which no implementing schedule appears in the regulations relied on here. Renewal requires the licensee to be otherwise entitled, to pay the renewal fee, and to submit proof of insurance and the renewal application. No education hours are a condition of renewal for any licensee class, as the programme page states; the title’s only education duty is the inspectors’ annual Board or Board-approved course, attached to a role that also forbids a financial interest in an HVACR business and requires any license held to be placed inactive during inspector employment. Inactive status, taken at renewal, forbids providing services, renews each cycle on fee and application without insurance proof, and returns to active status only on full compliance with the renewal requirements; an unrenewed inactive license expires on the same October calendar. Restoration after expiration allows application within four years on payment of the required fees; after four years the Board may require the initial-application process as if the applicant had never been licensed, and the regulation’s procedure adds a written letter covering the reasons for the lapse, the account of the late filing, and employment and duties since expiration, with a Board appearance if required and outcomes running from restoration on past-due fees to re-examination to treatment as a fresh applicant. A master-tier licensee may renew downward into a lower category, forfeiting the original license, and upward requalification requires passing the appropriate examination again unless the Board waives it for a licensee who originally earned the higher category by passing that examination. Licenses are not transferable, except on a contractor’s death, where the personal representative may retain the license for up to six months to wind up the business, extendable for extreme hardship by no more than an additional 24 months.
Insurance, display, and discipline hold the license up between renewals. The contracting bar — liability of at least $300,000 and property damage of at least $100,000, shown on a certificate stating the licensee’s name, both minimums, their combined $400,000 per occurrence total, and the policy number and expiration, with the Board named as certificate holder — carries these teeth: the Board may not issue or renew without the proof, cancellation requires notice at least ten days beforehand, and a licensee whose cover expires cannot legally continue to enter into contracts. Display requires the license and number in the principal place of business, the number on each vehicle and on all contracts and printed advertisements in the prescribed form, and written notice of any change of name, address, or employment at least ten working days before it takes effect. Reciprocity is a majority-vote waiver on strict conditions, including an active, equivalent, good-standing license earned under requirements at least equivalent to Maryland’s and a reciprocal waiver by the other state; the agreements the Board actually publishes are with Delaware and Virginia. A Maryland license is required regardless of home-state licensure or office location.
A study plan built on the bulletin
First, allocate by the six blocks. A quarter of the sitting is refrigeration and air conditioning; electrical and heating carry a fifth each. Study hours in those proportions cannot be badly wrong. Second, separate the code layers physically. Field material for the 2021 layer is never opened in examination practice. Third, rehearse the desk rules. Timed practice with the candidate’s own indexed, highlighted, unmarked books and permitted tabs only, inside 240 minutes, with the end-of-sitting review habit built in. Fourth, learn the ladder cold — the six classes, the statute-form gates, the credits, the two money layers, the October calendar, and the insurance bar. Fifth, verify the live details at scheduling: application channel, fee currency, and the current bulletin edition.
The errors this examination is built to catch
Studying the field edition for the room is the defining Maryland error: the 2021 code governs work through the field layers and governs no answer in the sitting. Importing a fuel gas code prepares a book that appears on no Maryland list at all. Planning the journeyman rung from the vendor bulletin’s paragraph understates the statute gate that the regulation and the Department both state. Adding the two money layers into a single cost misstates both. Carrying a superseded fee schedule — either of the two dead schedules in circulation — misbudgets the route. Assuming an education duty invents renewal hours the title does not impose on licensees. Counting specialties for a restricted license, in either direction, asserts what the sources leave conflicted. And missing the one-year fuse after passing lets a hard-won result expire unlicensed. Each is a layer error before it is a knowledge error, which is why this guide is organised by layers from its first section.
Frequently asked questions
Why does the bulletin list several mechanical code editions?
The bulletin as retrieved lists editions together with the operative instruction: effective May 15, 2025, only the 2018 edition will be used. Current sittings key to 2018 alone.
What is the score-reporting form of the pass standard?
The bulletin states that a passing grade of 70 points is required to qualify for licensure, the outline heading states a 70% minimum passing score, and the statute states a grade of at least 70 percent — three published forms of the one standard this guide uses.
Does the field really run on a newer code than the examination?
Yes, on the sourced layers: the Board’s code chapter points to the most recent mechanical code as incorporated in the Model Performance Code, which currently incorporates the 2021 edition, subject to local adoption and enforcement. The examination remains on the 2018 edition.
Can a journeyman reach the master license without the full apprentice route?
The master gate turns on three years of active experience under the named license classes and the examination; the credit provisions — formal study, qualifying non-conforming experience, and teaching — can shorten the experience showing on the statute’s terms.
How long does a passing result stay valid?
One year: licensure, with all applicable fees, must be applied for within one year of completing the examination for the results to remain valid.
When does enrollment open for the PassProfessor program?
The program is in the works and enrollment is not yet open. Leave an email address on this page and PassProfessor will write to you when the program is ready — and only about this program.