Iowa Journeyperson HVAC/Refrigeration Exam Guide: The Credential, the Refrigeration-Weighted Outline, and the Route Between Them

Iowa’s Journeyperson HVAC/Refrigeration license is issued by the Plumbing and Mechanical Systems Board within the Department of Inspections, Appeals, and Licensing, under Iowa Code chapter 105. Its own examination, through Kirkwood Community College, is an open-book sitting of 75 questions in two hours, with refrigeration carrying the largest share of the outline. The PassProfessor Iowa Journeyperson HVAC/Refrigeration program prepares candidates for that sitting and the Iowa licensing structure around it.

This program is part of the expanding PassProfessor catalog — join the notify list and we’ll email you when enrollment opens.

The credential at a glance

ItemVerified position
ProgramIowa Journeyperson HVAC/Refrigeration: the journeyperson examination in the HVAC-refrigeration discipline, titled by the examination provider as Journeyperson HVAC/Refrigeration with Gas
RegulatorPlumbing and Mechanical Systems Board (PMSB), within the Department of Inspections, Appeals, and Licensing (DIAL), under Iowa Code chapter 105 and 481 IAC chapters 425–435
Examination providerKirkwood Community College, the Board’s approved examination provider
Examination formatWritten and proctored, in person or online; 75 questions; two hours; open book with approved references only
Passing standardA score of 75 percent or better is considered passing — the Board’s general examination rule, at 481 IAC 429.6(2)(d)
Tested referencesModern Refrigeration and Air Conditioning, 21st edition; International Mechanical Code, 2024 edition; NFPA 54 National Fuel Gas Code, 2024 edition
Field codeState Mechanical Code: International Mechanical Code, 2024 edition, effective March 26, 2025
Fees, as separate instrumentsBoard examination-candidate fee $35 per trade examination; Kirkwood examination fee $119 per attempt; Board journeyperson license fee $180 for the three-year period
Credential termThree-year cycle, expiring June 30 in the renewal year
Administrator notePassProfessor is independent and is not affiliated with the Plumbing and Mechanical Systems Board, DIAL, or Kirkwood Community College

This guide follows the structure of the license itself. Iowa Code chapter 105, the Iowa Plumber, Mechanical Professional, and Contractor Licensing Act, creates the system; the Board’s rules at 481 IAC chapters 425–435 operate it — chapter 426 for the State Mechanical Code, chapter 428 for licensure fees, chapter 429 for application, licensure, and examination, chapter 430 for alternative pathways, chapter 431 for licensee practice, chapter 432 for continuing education, and chapter 434 for discipline. The licensing chapters were repromulgated effective June 19, 2024 and editorially renumbered from the Public Health title to the Inspections and Appeals title on April 2, 2025, so citations carrying the older title number belong to a superseded layer. The Board itself sits within DIAL, has twelve voting members, and includes among them two journeyperson mechanical professionals and two master mechanical professionals — the tier this guide covers is represented on the body that examines it.

The journeyperson position inside the Iowa system

The Board issues master licenses for plumbing, mechanical, HVAC-refrigeration, and hydronic professionals, and journeyperson licenses for plumbing, mechanical, HVAC-refrigeration, sheet metal, and hydronic professionals. The asymmetry is worth holding precisely: sheet metal has a journeyperson license and no master license. Within that map, the Journeyperson HVAC/Refrigeration license authorises work defined as HVAC and refrigeration, and nothing beyond it.

A journeyperson is defined by relationship as much as by skill: a person other than a master, engaged as a principal occupation as an employee of, or otherwise working under the direction of, a master. In practice the discipline is exact. The journeyperson works under the supervision of a master licensed in the discipline of the work being performed, supervises apprentices only inside the journeyperson’s own discipline and only while working for the same licensed contractor, and must not knowingly perform chapter 105 work for an unlicensed contractor. The business side is closed to this tier: engaging in the business requires a licensed master employed and actively in charge at all times, a sole proprietor performing the work must personally hold a master license, and the master of record — the individual with an active master license responsible for proper designing, installing, and repairing and actively in charge — is a master role by definition. A separate Contractor license carries the business itself, with its own place-of-business, insurance, bond, and registration requirements. Candidates who keep those three roles separate will find the administration questions considerably easier, because the sitting tests the separations.

Around the parent license sit two specialty sublicenses, Service Technician HVAC and Hearth Systems, each a sublicense of an HVAC-refrigeration or mechanical license. The Service Technician sublicense covers work from the appliance shutoff valve to the appliance and carries its own certification or degree qualification. A journeyperson holder of the parent license is not required to obtain a sublicense of it.

The route, step by step

Step one — build the apprenticeship record. Licensure requires at least four years of practical experience as an apprentice, and since January 1, 2010 that experience must be a registered apprenticeship training program. The apprentice must be Board-licensed and enrolled in such a program; eligibility begins at 18 with a high school diploma or equivalent, the registered ratio is one apprentice to one journeyperson unless a collective bargaining agreement specifies otherwise, and helper experience is not practical experience under the statute.

Step two — clear the examination gate. The gate to sit is lower than the gate to be licensed, and the distinction matters for timing. A candidate may sit on completion of a minimum of 36 months in a registered apprenticeship program, or on at least four years of experience from before January 1, 2010, with a notarized Affidavit of Employment attached for the pre-2010 basis. The general floor for any license is at least 18 years of age.

Step three — obtain Board approval. Submit the State of Iowa Examination Candidate Application, online or on paper, with the $35 candidate fee per trade examination, at least 15 business days before the intended sitting. Board staff verify the application and issue an Exam Approval Letter with the Kirkwood scheduling instructions. Approval lasts one year; within it, a candidate may test as many times as necessary, paying the Kirkwood fee for each attempt, and after the year expires the candidate reapplies with a fresh candidate application and fee. Applications carry criminal-history documentation duties, and a person unsure whether a record disqualifies them may petition the Board for an eligibility determination before applying.

Step four — sit and pass. The sitting is described in full below. The score appears on screen at the end, as a percent of correct answers.

Step five — apply for the license itself. Passing does not issue a license. The candidate submits the separate post-examination licensure application, and for the apprenticeship route the application is not processed until the Office of Apprenticeship certificate of completion has been issued and the applicant has graduated from the program. The initial license fee is prorated for a partial period, and a passing score expires if licensure is not applied for within two years of the notification of passing, after which the examination must be retaken and passed again.

The outline in full

Kirkwood states that each outline lists all topics covered in the examination, the approximate percentage of questions asked about each topic, the total number of questions, and the maximum time allowed. For this examination the total is 75 questions and the maximum time is two hours. The five areas follow, in the order a refrigeration-led study plan should meet them.

Refrigeration, Terms, System Operations — 24 percent

The largest block on the paper, at nearly one question in four, and the block that most distinguishes this sitting from a heating-led one. Its source text is Modern Refrigeration and Air Conditioning, 21st edition, and its centre of gravity is how refrigeration systems operate: the vocabulary of the trade, the cycle as a working system, and the operating judgements a journeyperson makes on equipment intended for food processing and product preservation, which is how Iowa’s own definition frames refrigeration. Candidates whose experience is concentrated in comfort heating should treat this block as the sitting’s main event rather than as a supplement, because the weighting makes refrigeration fluency the single largest determinant of the score.

Venting, Combustion, Gas Piping — 23 percent

The second block, close behind the first, gathers the fuel side of the discipline. Venting and combustion questions key to the mechanical code; gas piping questions key to NFPA 54, the National Fuel Gas Code, 2024 edition. That split is the block’s real demand: the candidate must know which book holds a given provision and find it there under time pressure, in an open-book room where the books are present but the clock is not generous. The presence of gas piping at this weight also reflects the statute — associated gas lines are inside Iowa’s definitions of both HVAC and refrigeration, which is why the examination carries “with Gas” in its title.

HVAC Principles, Terms, Administration, and Safety — 21 percent

The foundation block covers the principles and vocabulary of heating, ventilation, and air conditioning work, together with the administration and safety layer: Iowa’s licensing structure, the Board’s rules, and safe working practice. This is where chapter 105 enters the paper directly — scope definitions, supervision duties, the roles of master, journeyperson, apprentice, and contractor — and candidates who have read the statute’s definitions as working documents rather than as preamble hold an advantage here that no amount of equipment study replaces.

Boilers, Ducts, Electricals — 17 percent

A combined block spanning hydronic-adjacent equipment, air distribution, and the electrical content that sits inside this discipline’s actual scope. The electrical material should be read against Iowa’s narrow boundary: a licensee in this discipline is exempt from a chapter 103 special electrician’s license only to disconnect and reconnect existing air conditioning and refrigeration systems. Questions in this block test the work the license actually covers, at the depth a journeyperson directing daily work requires.

HVAC Installation Requirements — 15 percent

The smallest block covers how systems are installed to code: the mechanical code’s installation provisions applied to the equipment this license covers. Its modest percentage should not be mistaken for low importance — installation knowledge underpins the other blocks — but in a weighted sitting it is the area where additional study hours buy the fewest additional questions, and a disciplined plan allocates time accordingly.

Tested and adopted: two layers, one edition

Keep the layers separate even where they agree, because the habit protects candidates in every state and because Iowa’s history shows why. The tested layer is the reference set: the 2024 International Mechanical Code, the 2024 edition of NFPA 54, and Modern Refrigeration and Air Conditioning, 21st edition. The adopted layer is the State Mechanical Code, which adopts Sections 101–102 and Chapters 2–15 of the 2024 International Mechanical Code by reference, effective March 26, 2025. The two layers sit on the same mechanical code edition.

The history is the caution. Iowa’s previous State Mechanical Code rested on the 2018 edition, effective in 2019, and the move to 2024 was direct: no intervening edition was ever adopted in Iowa. Material or secondhand summaries built on that edition describe a code Iowa skipped. The fuel gas position is sharper still: Iowa does not adopt the International Fuel Gas Code at all. Iowa amendments replace the mechanical code’s references to that code with NFPA 54 in its current edition, NFPA 58, chapter 226 of Title 661, and the state plumbing code, so field and examination fuel gas run through the same NFPA 54 family. The Board must adopt the current mechanical code version within six months of its release, which is why Iowa’s alignment is a maintained position rather than an accident. Finally, a local jurisdiction is not required to adopt the state codes by ordinance and may be more restrictive where it does — the examination keys to the state position, while field work answers to the local one as well.

The sitting itself

The examination is written and proctored, conducted in person or online, and offered periodically during the year at rotating Iowa sites. Registration runs through Kirkwood by telephone; the candidate pays at registration by major card, receives a payment receipt and a confirmation email with test-site contact information, selects a test site and contacts it directly to schedule, and receives login credentials by email within the hour. The examination fee is $119 per attempt, paid to Kirkwood, and examination fees are non-refundable and non-transferable. A candidate who does not pass registers and pays again for a further attempt inside the Board’s one-year approval window; the statute states the same posture in general terms, that an applicant who fails shall be allowed to retake at a future scheduled time.

The room rules define the open-book discipline. Only approved references may be used. Code references may be bound or loose-leaf, photocopies may not be used, and no handwritten or additional notes may be in the books; anything written in during the examination is confiscated. Highlighting applied before arrival and permanent tabbing are acceptable; removable sticky notes are not. References are checked before and after the sitting and may not be shared. Scratch paper is provided and confiscated. A battery-operated, nonprogrammable calculator without storage or printing capability is permitted, with an architect’s scale or rule, magnifying glasses, and a translation dictionary if needed. Phones stay out of the testing area; a candidate who leaves the room signs out and in and loses the time. Candidates arrive at least 30 minutes early and present photo identification with a signature, the name exactly matching the registration name, suffixes included; without appropriate identification the candidate cannot test and must reschedule.

At the end, the score is shown on screen as the percent of correct answers. Results are confidential, revealed only to the applicant and the Board. The examination is not subject to review by applicants; on request, Kirkwood will provide information about the sections the applicant failed, but not access to actual questions or answers. Appeals about content, registration, scheduling, or administration go to Kirkwood in writing; faxed appeals are not accepted. Disability accommodations are provided at no additional charge, with application and documentation submitted at least two weeks before the examination date. No practical, drawing, or performance component forms part of this examination.

Fees in full, kept apart

Three instruments, three moments. The Board’s candidate fee is $35 per trade examination, paid with the candidate application; it purchases Board review and the approval letter. The Kirkwood examination fee is $119 per attempt, paid to Kirkwood at registration. The Board’s license fee is $180 for the three-year period; initial and renewal fees are the same figure and are nonrefundable, and an initial license issued for less than three years is prorated at one-sixth for each six-month period. Smaller Board charges belong to other transactions — paper applications, license-status verification, returned checks, a capped hearing fee, the eligibility petition — none of them part of this route’s three core instruments. Multiple active licenses purchased in a single transaction receive a combined reduction under the fee rule, and fee waivers exist for qualifying first-time applicants on household income and for qualifying discharged service members. The system never presents the three charges as one sum, and candidates budgeting for the route should keep them apart in the same way.

After the sitting: the credential and its clock

Iowa licenses run on a fixed triennial cycle: a three-year period expiring June 30 every three years, regardless of issue date. The current period runs July 1, 2026 through June 30, 2029, and the following period runs to June 30, 2032. Renewal opens May 1 of the third year, and renewal applications are due at least 30 days before expiration. The lapse ladder is graduated. A one-month grace period follows expiration without a late fee, and practice inside it carries no fines or penalties. Renewal during August adds a $60 late fee; renewal after August and through the following June 30 adds a $100 late fee; in both cases the renewal fee itself is also due and no examination is required. The license remains valid for practice for up to two months past expiration, then lapses and is invalid until reinstated. Reinstatement after a lapse of more than one year requires retaking and passing the applicable examination, or completing all continuing education for each missed period, and pays the full license fee without proration. Inactive status is available to a licensee not actively engaged at that level; it must be renewed, it is not valid for practice, reactivation runs by written request with payment of the active-license fee, and inactive journeyperson licensees remain subject to continuing education.

Continuing education for a single license of this kind totals eight hours in each three-year period: two hours of safety covering Iowa Occupational Safety and Health Act content, two hours of code covering the Iowa mechanical code, and four hours in the discipline. The statutory floor matches the rule. An hour means at least 50 minutes in one sitting; courses and instructors must be Board-approved; the same course attended twice in one period counts once; records must be kept, produced within 30 calendar days of a Board compliance request, and a good-faith deficiency may be cured within 120 calendar days. At most one-half of the hours may be taken online, so at least half are in person. Higher combined totals apply to holders of multiple licenses, and the combination election toward a Mechanical license — available at renewal to a holder of HVAC-refrigeration and hydronic licenses at the same level, with a higher education total in the combining period and no combining charge at renewal — is treated in full in the Mechanical license’s materials.

The alternative pathways deserve the same precision. The Board may license without examination only under a reciprocity agreement with a state of similar requirements that grants Iowans the same privileges, and the only agreement the Board publishes — with the South Dakota State Plumbing Commission, dating to May 2016 — covers plumbing licenses. No HVAC-refrigeration reciprocity is published, and no candidate should plan around one. Licensure by verification still requires proof of passing the applicable Iowa examination, although a temporary license may cover an otherwise qualified applicant in the interval. Licensure by work experience requires at least three years of full-time work — at least 1,700 hours in a year — inside the four years before application, together with passing any necessary examinations. A narrow examination and experience waiver exists for military applicants whose deployment fell inside a specific window in 2008 and 2009 and who previously passed a substantially similar examination or held licensure in the same trade and level; it is date-bound on its face and should not be generalised. Federal refrigerant-handling certification stands outside this system entirely: no Iowa statute, rule, or Board page makes it a condition of this license.

A study plan built on how this examination is actually put together

Sequence by weight and by book. First, refrigeration operations from the refrigeration text, because the largest block rewards the deepest fluency and comfort-heating experience does not substitute for it. Second, the gas piping provisions of NFPA 54 alongside the venting and combustion provisions of the mechanical code, practised as a sorting exercise — for every provision, which book, which chapter — until the sorting is automatic. Third, the mechanical code as a navigation instrument: tabbed permanently, highlighted before arrival, and drilled under the two-hour clock, because open book rewards retrieval speed rather than recognition. Fourth, the Iowa layer: chapter 105 definitions, the supervision discipline, the approval route, and the renewal clock. Fifth, timed mixed practice across all five areas in outline proportion, so the felt experience of the sitting — refrigeration-heavy, gas-heavy, clock-bound — is familiar before the day itself.

The errors this examination is built to catch

The sitting catches layer errors and edition errors. Studying the intervening mechanical code edition — the one Iowa never adopted — misaligns every code answer. Studying fuel gas from the international fuel gas code does the same for the gas block, in a state that has never adopted that code. Treating this examination as the master examination misjudges both its size and its outline; the two sittings are separate, with separate outlines, and only this one’s figures govern here. Reading “open book” as “unprepared” fails against a two-hour clock and a confiscation rule for anything written into the books during the sitting. Merging the three fees into one imagined total misstates the route; approval, attempt, and license are separate instruments. Assuming the license follows the pass skips the separate licensure application and risks the two-year expiry of the passing score. And assuming reciprocity from a plumbing agreement that does not reach this discipline wastes a season that the apprenticeship record could have used.

Iowa in one view

Iowa in one view is a supervised tier examined on its own paper. The journeyperson stands between the apprentice below and the master above, works only under a master’s direction, and is examined separately on an outline that puts refrigeration first, gas work second, and the state’s own licensing structure inside the paper rather than outside it. The code position is unusually clean — one mechanical code edition for the examination and the field alike, reached by a jump that skipped an edition — and unusually easy to get wrong from secondhand material, which preserves the skipped edition and the unadopted fuel gas code as if Iowa used them. The candidate who studies the three listed references, in the listed editions, in outline proportion, and who treats the Board’s approval, the room rules, and the separate licensure step as parts of the examination rather than errands around it, is studying the sitting Iowa actually gives. The companion program page at /iowa-journeyperson-hvac-refrigeration-exam-prep/ summarises the credential and the route; this guide is the full account.

Frequently asked questions

Is this the same examination as the Master HVAC/Refrigeration examination?

No. The Board adopts a standardised examination for each license type, and the journeyperson sitting has its own outline, its own count, and its own duration. Figures belonging to the master sitting do not describe this one.

What score passes this examination?

The Board’s general examination rule, at 481 IAC 429.6(2)(d), states: “A score of 75 percent or better is considered passing.” Kirkwood states the same standard for each of its examinations. The rule is tier-general; it governs this journeyperson examination in its own right.

Why does refrigeration carry the largest share?

Because Kirkwood’s published outline weights it so: Refrigeration, Terms, System Operations is 24 percent of the 75 questions, ahead of Venting, Combustion, Gas Piping at 23 percent.

May a candidate bring an older edition of the mechanical code?

A reference book physically brought to the examination may be from any edition, under Kirkwood’s stated allowance. The questions, however, are based on the listed editions — the 2024 mechanical code, the 2024 edition of NFPA 54, and the 21st edition of the refrigeration text — so an older book answers a current paper at a disadvantage.

What experience must a candidate show before sitting?

Completion of a minimum of 36 months in a registered apprenticeship program, or at least four years of pre-2010 experience supported by a notarized affidavit. Licensure itself requires the full four years of registered apprenticeship experience, with the completion certificate issued.

Does passing issue the license?

No. Licensure is a separate application after passing, the fee is prorated for a partial period, and a passing score expires if licensure is not applied for within two years of notification.

When does enrollment open for the PassProfessor program?

The program is in the works and enrollment is not yet open. Leave an email address on this page and PassProfessor will write to you when the program is ready — and only about this program.