Arizona A/C & Refrigeration Contractor (CR-39) Exam Guide: The Dual Classification, the Qualifying Party, and the Route to the License

CR-39 Air Conditioning and Refrigeration is Arizona’s specialty dual classification — commercial and residential together, without solar — built from C-39 and R-39R, licensed by the Arizona Registrar of Contractors to a business entity through a qualifying party who must receive a grade of at least 70% on each required examination. This guide explains the classification, its scope lines, its two examinations, and the route between application and license.

This program is part of the expanding PassProfessor catalog — join the notify list and we’ll email you when enrollment opens.

The credential at a glance

ItemVerified position
ProgramArizona A/C & Refrigeration Contractor (CR-39): specialty dual (commercial + residential), no solar — C-39 + R-39R under AAC R4-9-104
RegulatorArizona Registrar of Contractors (AZ ROC), under ARS Title 32, Chapter 10 and AAC Title 4, Chapter 9
License holderThe business entity, through a qualifying party; the license is nontransferable
Required examinationsThe Trade Examination and the Statutes and Rules Examination (SRE), as AAC R4-9-106(A) defines them
Trade examination vendorPSI
Trade examination80 scored questions; 210 minutes; open book as to the allowed references only
Passing standardA grade of at least 70% on each required examination (AAC R4-9-106(C))
Tested codesInternational Mechanical Code, 2018 Edition, and International Fuel Gas Code, 2018 Edition
Adopted code layerNo single statewide mechanical-code adoption; local adoption varies by jurisdiction
SRE deliveryProvided and maintained by AZ ROC; delivered online only through GMetrix; $61 paid directly to GMetrix
Administrator notePassProfessor is independent and is not affiliated with the Arizona Registrar of Contractors

This guide is the companion to the Arizona A/C & Refrigeration Contractor (CR-39) program page at /arizona-ac-refrigeration-contractor-cr-39-exam-prep/. The program page states the position; this guide walks the route through it — classification, scope, qualifying party, then the two examinations in the order a candidate meets them.

How the classification is built

Arizona’s air conditioning and refrigeration classifications come in commercial, residential, and dual forms, and in a no-solar family and an including-solar family. CR-39 belongs wholly to the no-solar family. Under AAC R4-9-104, the dual classification combines C-39, the commercial no-solar classification defined at AAC R4-9-102, and R-39R, the residential no-solar classification defined at AAC R4-9-103; the dual licensee holds the scopes of both in one classification. Candidates must hold that construction firmly, because the family is a known trap: the residential class that belongs inside CR-39 is R-39R, and decisions made against the wrong residential class are decisions made against the solar family — a different set this program does not address.

The dual construction also explains the examination structure. One trade examination serves the R-39R, C-39, and CR-39 classifications together: the Registrar examines the shared trade once, and the classification granted follows the application. The dual scope is a licensing fact about what the resulting license allows, not a second trade sitting.

A contractor license, not a trade tier

Arizona’s structure must be understood on its own terms before any examination detail makes sense. Contractor licensing is governed by ARS Title 32, Chapter 10, and the rules at AAC Title 4, Chapter 9. The license belongs to the business entity — sole proprietorship, partnership, LLC, or corporation — and is nontransferable. The qualifying party is the person through whom the entity qualifies: a person with an ownership interest in the licensee or regularly employed by it, actively engaged in the classification, responsible for the licensee’s actions, and possessed of the necessary experience, knowledge, and skills, as the definitions at ARS § 32-1101 provide and the requirements at § 32-1122 develop.

Chapter 10 creates no journeyman, technician, apprentice, or master license class for this work. That is a verified negative, established by reading the chapter’s class structure: there is no Arizona HVAC trade ladder of the kind many other states maintain. The consequences run through the whole route. The examination candidate is a qualifying party, not an individual licensee-in-waiting; the experience gate is the qualifying party’s trade experience, not service in a lower Arizona tier; and an out-of-state trade tier cannot be converted into an Arizona one, because there is no Arizona tier to convert into — the waiver rules, covered below, are the only bridge, and they are drawn narrowly.

The scope, line by line

CR-39 allows the scopes of work permitted by the commercial C-39 and the residential R-39R licenses. Stated in full, the incorporated scope covers installing, altering, and repairing refrigeration and evaporative cooling systems; heating systems of wet, dry, or radiant type; ventilation systems, including duct work, air filtering devices, water treatment devices, pneumatic or electrical controls, and control piping; thermal and acoustical insulation of refrigerant pipes and ductwork; vibration isolation; liquid fuel piping and tanks; water and gas piping from the service connection to the equipment it serves; and testing and balancing of refrigerant, cooling, and heating circuits and air handling systems.

Inside that breadth sit the lines the examination loves. Wet systems — steam or hot water boilers and coils, or baseboard convectors — are limited to 30 PSIG operating pressure and 220°F for hot water, and to 15 PSIG for steam; those three numbers belong together, as a single wet-system boundary. Dry systems include gas-fired furnaces and space heaters. The electrical boundary is the sharpest line in the scope: a new circuit may be added to the existing service panel or sub-panel; installation of a new service panel or sub-panel is excluded. Candidates should practise classifying described jobs against these lines until the classification is immediate.

The licensing threshold frames the scope from outside. A license is generally required where a permit is required, regardless of price, and the statute’s handyman exemption does not apply to work involving connecting to any supply of natural gas, propane, or other petroleum or gaseous fuel — so for a classification whose scope includes gas piping and gas-fired equipment, gas-connected work sits inside the licensing requirement, and acting as a contractor without a license is a criminal offence. Neighbouring classifications mark the scope’s edges as well, and CR-39 items must be answered from CR-39 scope, never from a neighbour’s.

The qualifying party gate in depth

The centre of the gate is experience: a minimum of four years’ practical or management trade experience, at least two of which must have been within the last ten years, dealing specifically with the type of construction sought, under ARS § 32-1122(E). Two features of that sentence deserve emphasis. The recency requirement means that long-ago experience, however deep, does not by itself satisfy the gate — two of the four years must sit inside the last decade. And the specificity requirement means the experience must deal with the type of construction sought, which for CR-39 is air conditioning and refrigeration construction of the kind the classification covers. Technical training in an accredited college or university or a manufacturer’s accredited program may substitute for a portion of the experience, capped at two years of the four — so training can carry a candidate halfway to the gate, never all the way.

The Registrar holds calibrated discretion around the gate: the requirement may be reduced where conclusively shown excessive for the craft; work-experience documentation shall be waived where the qualifying party is or previously was a qualifying party in Arizona in the same classification; and experience may be waived administratively, in whole or part, on a trade examination passed not more than two years before application or a valid nationally recognised certification, as AAC R4-9-119(A) and R4-9-106(F) provide. Timing binds the examination to the application: qualification must be shown by written examination taken not more than two years before application, and results are submitted within two years from the date of passing. An examination passed and left unused ages out.

The application’s personal gates are mechanical: every person listed must be 18 or older — no license issues to a minor, to a partnership with a minor partner, or to a corporation with a minor officer; corporation and LLC applicants must be registered with the Arizona Corporation Commission and in good standing; every person named undergoes a background check, which expires 90 days from completion; and every individual named provides government-issued photo ID. Candidates should sequence their paperwork against that 90-day clock.

Waivers and the absence of reciprocity

Arizona has no direct reciprocity with any state, and this guide uses the word reciprocity only to deny it. What exists instead is a pair of waivers with different strengths. Inside Arizona, the waiver is mandatory in form: the Registrar shall waive the trade examination if the qualifying party is or previously was a qualifying party in Arizona in the same classification within the preceding five years. From outside Arizona, the waiver is discretionary and narrower: the Registrar may waive the trade examination only where the qualifying party held a comparable license in another state within the past five years, obtained by a trade examination. The SRE has its own waiver rule, stated separately below. Notice the recurring five-year window — it runs through both waivers and the SRE provisions — alongside the two-year examination currency and the 90-day background check, as the structural numbers of Arizona licensing.

Examination one: the PSI Trade Examination

AZ ROC has contracted with PSI to conduct its trade examination program, and the CR-39 trade examination is a PSI computer-based examination, available at a test center or remotely proctored. Its mechanics are exact: 80 scored questions; 210 minutes; a 15-minute introductory tutorial before the examination that does not count as examination time; and, separately, 5 to 10 experimental questions that may additionally be administered, will not be scored, and will count against examination time. Every part of that sentence matters. The scored count is 80 — not 80 plus the experimental questions. The clock is 210 minutes, and experimental questions consume it, which is why candidates pace against the scored core while expecting questions that will not affect the result and cannot be identified in the room. Scores display on screen at the end and a report is emailed; a fail report includes diagnostics by examination type, which the retake plan below puts to use.

Book status needs its exact form. The examination is open book only as to the allowed references, and for CR-39 the allowed list has three entries: 29 CFR Part 1926, with latest available amendments, or the CFR selections volume published for PSI candidates; the International Fuel Gas Code, 2018 Edition; and the International Mechanical Code, 2018 Edition. Nothing else on the preparation shelf enters the room: the textbooks used to prepare the questions are not allowed in the center. Candidates bring their own allowed references, prepared beforehand: highlighting, underlining, annotation, and indexing happen before the session, permanent tabs only, no loose papers, and no writing in the books during the session. A silent, nonprinting, non-programmable calculator is allowed. The open-book advantage is earned at home, in the condition of the two code books a candidate carries in — tabbed, indexed, and familiar.

The fee for one examination is $66, paid directly to PSI; the two-examination fee of $116 stands in the same PSI table. The fee applies on a first attempt or a repeat alike, registration fees are not refundable or transferable, and the fee is valid for one year. Under AAC R4-9-106(B), examinations must be administered at least once a week. Cancellation discipline is strict: cancelling or rescheduling without forfeiting the fee requires notice two days before the scheduled date, voicemail and email are not acceptable cancellation, and late cancellation, a no-show, late arrival, or lack of proper ID forfeits the fee.

The trade outline in full

Eighty scored questions, twelve areas. Refrigeration takes 12, Air Conditioning takes 12, and Warm Air Heating takes 12 — a three-way tie at the top that defines preparation: a candidate strong in only one of its three great areas starts with a ceiling no excellence elsewhere can lift. Controls and Motors follows at 8. Then a band of five-question areas: Fuel Piping Systems; Water Piping Systems; Steam, Hot, Chilled, and Condensing Water; and Testing, Balancing, and Inspections. Boilers, Ventilation, Evaporative Coolers, and Sizing and Estimating take 4 each. The tail matters more than its size suggests: evaporative cooling is a small block with a distinctly Arizonan flavour, and sizing and estimating rewards the candidate who can do the trade’s arithmetic rather than only describe it. The twelve areas total exactly 80, matching the scored count.

Reference discipline runs through the outline. For code questions, the examinations are based only on the edition of the code book listed — the 2018 editions of the IMC and the IFGC. Except for code books, answers may be based on later editions of the preparation texts. That asymmetry is a study instruction in disguise: code study is edition-locked, text study is not, and a candidate who reverses the two — current code book, ageing texts — has the discipline exactly backwards.

Examination two: the Statutes and Rules Training Course and Exam

The second required examination is the Statutes and Rules Examination, and its delivery vehicle is the AZ Statutes and Rules Training Course and Exam — the SRE. Three facts define it. It is a training course and exam together: computer-based and open-book. It is provided and maintained by AZ ROC itself, not by the trade examination vendor. And it is delivered online only, through GMetrix, for a fee of $61 paid directly to GMetrix. PSI does not administer, schedule, or collect for the SRE, and any material that routes the SRE through PSI — or describes a separate additional examination standing between the trade examination and the license — misdescribes the Arizona structure. AAC R4-9-106(A) defines exactly two examinations, and this is the second of them.

The SRE is required for new license applicants who were not previously listed as the qualifying party on another Arizona contractor’s license within the last five years. Its waiver rule mirrors its requirement: the SRE cannot be waived unless the qualifying party has been a qualifying party on an Arizona license within the past five years. It is completed and passed at 70%, under the same rule-form standard — a grade of at least 70% on each required examination, per AAC R4-9-106(C). This guide deliberately states no question count and no time limit for the SRE: none is verified in the sources behind this guide, and candidates should distrust any source that supplies one confidently. What can be prepared is the substance — Arizona’s contractor statutes and rules as the Registrar teaches them in its own course.

The passing standard, once more, in its exact form

AAC R4-9-106(C): on each required examination, the qualifying party must receive a grade of at least 70%. The Registrar states the same form, and the trade outline prints a 70% minimum passing score. This guide repeats the rule form rather than a shorthand because the shorthand loses the operative word — each. The standard attaches to the two examinations independently, so preparation should track two separate readiness judgements, and a candidate ready for only one of them is not yet ready.

Retakes and the shape of a second attempt

Failure has a timetable in Arizona. Under AAC R4-9-106(D), a qualifying party who does not reach the standard may retake only after waiting 30 calendar days from the first failure, 30 calendar days from the second failure, and 90 days from any other failure. PSI states the same regime in operational form: a 30-day wait, three attempts allowed, and a 90-day waiting period between schedules for a fourth and subsequent attempt. A new appointment cannot be made the same day as an examination. The structure rewards candidates who treat the waiting periods as study periods with a fixed end: the fail report’s diagnostics identify where the attempt was lost, and the outline weights identify how much each lost area was worth. Attempting again on the first permitted day without a diagnostics-led repair wastes the scarcest resource in the regime — attempts before the 90-day cadence begins.

Tested 2018; adopted locally; disciplined statewide

The code-layer lesson for Arizona is a study in asymmetry. The tested layer is precise and singular: IMC 2018 and IFGC 2018, named in the outline, allowed in the room, and exclusive for code questions. The adopted layer is deliberately unstateable as a single edition: Arizona has no single statewide mechanical-code adoption in the sources behind this guide, and local adoption varies widely by jurisdiction. What is statewide is not an edition but a duty — compliance with the locally applicable code is a discipline standard under ARS § 32-1154(A)(2)(b). Prepare for the examination in the 2018 editions, work in the field under whichever local code applies, and never let a local adoption rewrite the examination’s reference list. No city-specific adoption is stated in this guide, because none is in its sources.

After the examinations: the license in force

The license, once issued, is biennial — a two-year license. A surety bond is required before an original license and must be in full force for renewal; the license is suspended by operation of law on bond cancellation unless a replacement is on file. This guide states the bond requirement without figures: the amounts are volume-tiered rule figures, and no single flat figure honestly represents them.

Two closing negatives are recorded in the qualified form the sources support. No ROC continuing-education requirement was found in ARS Chapter 10, AAC Title 4 Chapter 9, the PSI bulletin, or the ROC licensing pages behind this guide — a search result candidates should hold as such. No general-liability insurance dollar minimum appears in the statute or rules as pulled; the licensing statute’s insurance content is the workers’ compensation compliance attestation, by policy number or proof of self-insurance where that coverage is required. Neither negative should be inflated into a broader claim: both are part of the verified picture, stated exactly as far as the search reached.

A study plan

First, the classification. Learn the CR-39 construction — dual, no-solar, C-39 plus R-39R — and the qualifying party structure until both can be stated without notes. Second, the scope lines: the wet-system boundary of 30 PSIG and 220°F for hot water and 15 PSIG for steam, and the electrical line between a new circuit and a new service panel, practised against described jobs. Third, the outline by weight: the three 12-question areas as the core, Controls and Motors next, then the five- and four-question bands. Fourth, the code books as objects: IMC 2018 and IFGC 2018, tabbed and indexed before any timed practice, because their condition in the room is part of the candidate’s equipment. Fifth, the statutes and rules substance through the Registrar’s own course material, tracked as a separate readiness judgement from the trade paper, under the each-examination standard. Sixth, mixed timed practice against the 210-minute frame, pacing set against the 80 scored questions while expecting unscored experimental questions to consume time without yielding marks. Throughout, sort errors by kind — scope-line, code-edition, outline-weight, and Arizona-structure errors — because each kind is repaired by a different kind of study.

The errors this examination is built to catch

Misbuilding the classification — preparing against the wrong residential class, or importing including-solar material into a no-solar program — fails before the first question. Hunting for a trade ladder that Chapter 10 does not contain wastes the orientation period; the qualifying party structure is the structure. Inventing a third examination — or routing the SRE through PSI — misdescribes the two-examination rule at AAC R4-9-106(A). Merging the counts — pacing against a total that adds experimental questions to the 80 scored — miscalibrates the whole sitting. Bringing the wrong room: unprepared code books, disallowed texts, or a programmable calculator converts an open-book advantage into a logistics failure. Edition drift — answering code questions from a later edition or a local adoption — ignores the outline’s rule that code questions rest only on the listed edition. Averaging the standard, as if a strong trade result could offset a weak statutes and rules result, contradicts the each-examination form of AAC R4-9-106(C). And letting the clocks lapse — the two-year examination currency, the 90-day background check — turns a passed examination into a route that must be restarted.

What the PassProfessor program will cover

The program covers the full verified structure of CR-39: the classification’s construction and scope lines; the qualifying party gate, its experience rule, and its waiver bridges; the PSI trade examination at its published mechanics and outline weights, keyed to IMC 2018 and IFGC 2018; and the SRE in its correct place and form, as the Registrar’s own course and exam delivered through GMetrix. Practice material is original, written from scratch against primary sources.

PassProfessor is an independent preparation provider, not affiliated with the Arizona Registrar of Contractors, PSI, or GMetrix. This guide and its program are preparation only; the Registrar alone licenses. Enrollment is not yet open while the program is in the works as our catalog expands through the Arizona classifications. Leave an email address and PassProfessor will write to you when the program is ready — and only about this program.

Frequently asked questions

How is CR-39 constructed?

Under AAC R4-9-104, CR-39 is the dual no-solar classification combining C-39, the commercial no-solar class, with R-39R, the residential no-solar class. It allows the scopes of both.

What are the wet-system limits inside the scope?

Wet systems are limited to 30 PSIG operating pressure and 220°F for hot water, and 15 PSIG for steam.

What electrical work does the scope allow?

A new circuit may be added to the existing service panel or sub-panel. Installation of a new service panel or sub-panel is excluded.

Who takes the examinations?

The qualifying party — the person with an ownership interest in the licensee or regularly employed by it, actively engaged in the classification and responsible for its actions. The license itself belongs to the business entity.

How much experience must the qualifying party show?

Four years’ practical or management trade experience in the type of construction sought, at least two of those years within the last ten years. Accredited training may substitute for a portion, capped at two years of the four.

Does Arizona reciprocate with other states?

No. Trade-examination waivers exist in two forms: a mandatory in-state waiver for a qualifying party in the same classification within the preceding five years, and a discretionary out-of-state waiver where a comparable license was obtained by a trade examination within the past five years.

What does the trade examination cost?

$66 for one examination, paid directly to PSI. The SRE costs $61, paid directly to GMetrix.

May preparation textbooks be taken into the trade examination?

No. Only the allowed references enter the center: 29 CFR Part 1926, the International Fuel Gas Code 2018 Edition, and the International Mechanical Code 2018 Edition.

What if I fail?

Waiting periods apply: 30 calendar days from the first failure, 30 from the second, and 90 days from any other failure, under AAC R4-9-106(D). The fail report includes diagnostics by examination type.

How long does the license run?

Licenses are biennial — two-year licenses — with a surety bond required before an original license and kept in force for renewal.

Is PassProfessor affiliated with the Registrar of Contractors?

No. PassProfessor is an independent preparation provider, and this guide is preparation material only.

When does enrollment open?

The program is in the works and enrollment is not yet open. Leave an email address on the program page at /arizona-ac-refrigeration-contractor-cr-39-exam-prep/ and PassProfessor will write to you when the program is ready — and only about this program.