Part of the expanding PassProfessor catalog: this guide covers the Certified Energy Manager examination as AEE publishes it — 130 multiple-choice and true/false questions in four hours, open book, 120 scored and 10 unscored trial questions, fourteen Body of Knowledge subjects published as percentage ranges with HVAC Systems and Building Envelope largest, eligibility that pairs education with related experience plus mandatory approved training, and a minimum score of 700 points. PassProfessor’s companion practice program is in the works, built to Body of Knowledge 2.0.
The program is in the works, built on the published outline for this examination. Join the notify list and we will email you when enrollment opens — then use this guide to plan your preparation area by area.
The Certified Energy Manager is the working energy professional’s credential: it belongs to the people who audit buildings and plants, price energy, specify systems, and then prove the savings held. The examination is broad and calculation-forward by design — economics, audits, electrical systems, HVAC, steam, industrial systems, and the management frameworks that tie them together. PassProfessor’s Certified Energy Manager program is in the works as part of the expanding PassProfessor catalog, built on AEE’s published Candidate Handbook and Body of Knowledge and Study Guide, and weighted to the midpoints of the percentage ranges AEE publishes for its fourteen subjects.
This guide does the planning work in the open: it states the examination’s verified facts, walks the official outline area by area with a preparation method for each area, explains scoring in the certifying body’s own terms, and ends with a study plan that follows the outline. Everything factual in it comes from the certifying body’s published materials recorded in this guide’s internal sources section; where those materials direct candidates to confirm a current detail — a fee, a date, a delivery option — the guide says so rather than printing a figure that could age.
Which examination is this?
This page covers one credential only: the Certified Energy Manager (CEM), from the Association of Energy Engineers (AEE), established in 1981 and accredited by the ANSI National Accreditation Board under ISO/IEC 17024. This program builds the U.S. version of the examination. It is preparation for the CEM examination itself — not for the Energy Manager In-Training (EMIT) designation as a separate test, because EMIT candidates pass the same examination; EMIT is the bridge AEE provides when a candidate has the education but not yet the experience, and it is covered on this page.
The real exam at a glance
| Fact of record | Detail |
|---|---|
| Credential | Certified Energy Manager (CEM) — AEE’s flagship credential, established in 1981; the program is accredited by the ANSI National Accreditation Board under ISO/IEC 17024 |
| Format | 130 multiple-choice and true/false questions, 4 hours, open book and open notes; 120 scored questions and 10 unscored trial questions placed at random (U.S. version) |
| Open-book rules | Only printed reference materials, organized and bound, plus a stand-alone scientific, business, financial, or graphing calculator with no internet capability. Phones, laptops, tablets, and cameras are prohibited, and writing in books or notes during the examination is prohibited |
| Scoring | AEE’s Candidate Handbook states a minimum score of 700 points. AEE publishes no point scale and no percent-correct equivalent |
| Delivery | In person at the end of an approved training program, or remotely proctored — remote scheduling is for candidates who have completed an approved preparatory course or are retaking |
| Eligibility | One of AEE’s six education-and-experience paths (see the eligibility section), plus mandatory attendance at an AEE-approved training program |
| Fees (U.S.) | Application and examination $500, nonrefundable; retest $250; renewal $300 every 3 years, as AEE publishes them. Confirm current fees when you apply |
| Retakes | A minimum 60-day wait applies before a retest |
| Keeping the credential | Certification renews every 3 years with continuing education |
Who can take this exam, and what does it certify?
CEM is not open-enrollment. AEE’s published table pairs education with related experience in energy engineering or energy management: a four-year engineering or architectural degree, or a PE or RA license, with 3 or more years; a four-year degree in technology, environmental science, physics, or earth science with 4 or more years; a four-year degree in business or a related field with 5 or more years; a two-year energy management associate degree with 6 or more years; a two-year associate degree with 8 or more years; or no degree with 10 or more years. Training is mandatory for every candidate: all candidates must attend an AEE-approved training program. Candidates who meet the education bar but not yet the experience can earn the Energy Manager In-Training designation by attending an approved program and passing the same examination; EMIT is valid for 6 years while experience accrues, and the full CEM follows when the experience requirement is met. The credential is awarded by AEE alone; this program is preparation for its examination.
What makes this test demanding?
This examination tests a practitioner, not a reader. Its centre of gravity is applied calculation under time pressure — energy accounting, tariff structures, motor and HVAC calculations, audit arithmetic — performed open-book, which changes the skill being tested: the book rewards the candidate who knows which method applies and can execute it quickly, and punishes the candidate who must first discover the method. Add fourteen subjects of genuine breadth and the preparation conclusion follows: drill the calculations until the methods are fluent, learn each subject’s judgment calls, and practise whole-bank simulations against the four-hour clock.
The outline, area by area
Body of Knowledge 2.0 defines fourteen subjects. AEE publishes a percentage range for each; the practice bank is weighted to each range’s midpoint, and the table shows the range, the bank, and the share of a 130-question practice simulation each subject carries.
| Body of Knowledge subject | AEE published range | Practice questions |
|---|---|---|
| HVAC Systems and Building Envelope | 10–16% | 195 |
| Energy Audits and Instrumentation | 7–11% | 135 |
| Electrical Power Systems and Motors | 7–11% | 135 |
| Operations, Maintenance and Commissioning | 7–11% | 135 |
| Energy Accounting and Economics | 6–10% | 120 |
| Building Automation, Controls and Artificial Intelligence Systems | 6–10% | 120 |
| Energy and Sustainability Policies, Codes and Standards | 6–8% | 105 |
| Industrial Systems | 6–8% | 105 |
| Energy Rates, Tariffs and Supply Options | 5–7% | 90 |
| Lighting Systems | 5–7% | 90 |
| Boiler and Steam Systems | 4–6% | 75 |
| Distributed Generation and Renewable Energy Systems | 4–6% | 75 |
| Energy Storage Systems | 3–5% | 60 |
| Energy Savings Performance Contracting and Measurement and Verification | 3–5% | 60 |
| Total | — | 1,500 |
What does HVAC Systems and Building Envelope cover?
The largest subject, because HVAC is where most buildings spend their energy: heating, cooling, and ventilation systems and how they are selected and controlled; building loads and the psychrometric reasoning underneath them; efficiency measures such as COP, EER, and SEER and the conversions among them; and the envelope itself — heat transfer through walls, roofs, and glazing — as the load the systems must serve. Envelope and system are one subject here because the examination treats them as one problem.
How should you prepare for HVAC Systems and Building Envelope? Build the load picture first — envelope, internal gains, ventilation — then the systems that meet it. Candidates who start with equipment meet calculation items whose inputs they cannot yet derive.
Reduce the load before resizing the plant: envelope improvements change every downstream calculation, and items are built to reward seeing that order.
What does Energy Audits and Instrumentation cover?
How energy use is found, measured, and proven: the ASHRAE audit levels — the walk-through of Level I, the detailed analysis of Level II, and the investment-grade depth of Level III — and what each level can and cannot promise; instrumentation and measurement practice; unit conversions among kilowatt-hours, Btu, and therms; load factors; and benchmarking through energy use intensity and tools such as ENERGY STAR Portfolio Manager. This subject supplies the evidence every other subject’s recommendations stand on.
How should you prepare for Energy Audits and Instrumentation? Practise conversions until they are automatic — audit items hide simple arithmetic inside unit changes, and time lost there is time taken from harder items later in the sitting.
Match the audit level to the decision: a Level I answer offered where capital investment needs Level III evidence is the subject’s favourite wrong choice.
What does Electrical Power Systems and Motors cover?
The electrical backbone: three-phase power and its calculations, power factor and the cost of a poor one, demand and how it is billed, motor loading and efficiency, and the affinity laws that govern fans and pumps — the laws that make a small speed reduction worth a large energy saving. Motors consume the majority of industrial electricity, and this subject tests whether the candidate can do the arithmetic that finds the waste.
How should you prepare for Electrical Power Systems and Motors? Drill the core calculations — three-phase power, power factor correction, motor load, affinity-law savings — until the set-up of each is immediate; the numbers are friendly, the method choice is the test.
Affinity laws reward the prepared: flow varies with speed, power with its cube — an item that offers a linear saving for a speed reduction is offering a trap.
What does Operations, Maintenance and Commissioning cover?
Keeping savings alive after the project team leaves: operations practice that holds setpoints and schedules where they were commissioned, maintenance strategies from reactive to preventive and predictive, and commissioning in all its forms — initial, retro-, and monitoring-based — as the discipline that verifies a building performs as intended, and keeps verifying. Energy savings decay by default; this subject tests whether the candidate knows the practices that arrest the decay.
How should you prepare for Operations, Maintenance and Commissioning? Learn the failure modes: drift, override, deferred maintenance, and the unreviewed schedule. Items present a building whose performance has slipped and ask which practice recovers it.
Commissioning is a process, not an event: an option that verifies once and walks away loses to an option that monitors and recommissions.
What does Energy Accounting and Economics cover?
The money mathematics of the profession: energy accounting that tracks consumption and cost honestly, and the economic tests that decide projects — simple payback and its limits, net present value, internal rate of return, life-cycle cost, and savings-to-investment ratio — applied with clean numbers and full computations. Every other subject’s recommendations eventually arrive here to be judged, which is why fluency in this subject pays across the whole examination.
How should you prepare for Energy Accounting and Economics? Practise each method on the same project until the differences among their verdicts make sense; items test method selection as much as arithmetic — the distractor is usually the right method’s neighbour.
Simple payback ignores everything after the payback year: an item testing life-cycle thinking marks the payback-only answer wrong even when its arithmetic is right.
What does Building Automation, Controls and Artificial Intelligence Systems cover?
The nervous system: building automation and control strategies — scheduling, setbacks, resets, demand limiting, and optimal start — sensors and points, sequences of operation, and the arrival of artificial intelligence in fault detection, prediction, and optimization under BoK 2.0. Controls items test whether the candidate understands that a control strategy is an energy strategy: the same plant, controlled well or badly, is two different buildings.
How should you prepare for Building Automation, Controls and Artificial Intelligence Systems? Think in sequences: what is sensed, what is decided, what is actuated, and what happens when each fails. Items describe a misbehaving building and ask which part of the sequence is at fault.
The cheapest energy measure is often a schedule: an option that stops equipment running unoccupied hours usually beats an option that replaces equipment that then runs the same hours.
What does Energy and Sustainability Policies, Codes and Standards cover?
The framework the profession works inside: energy and sustainability policy at the levels that bind projects, codes and standards in use — ASHRAE 90.1 and 62.1 awareness among them — ISO 50001 energy management, and the decarbonization content BoK 2.0 added: greenhouse gas accounting across scopes 1, 2, and 3, electrification, and carbon metrics. Items test what these instruments are and how they are used in practice — never a specific code section number.
How should you prepare for Energy and Sustainability Policies, Codes and Standards? Learn each instrument by its job: what it requires, whom it binds, and what evidence satisfies it. Policy items fail candidates who know names but not functions.
Scope discipline decides emissions items: direct emissions, purchased-energy emissions, and value-chain emissions are different ledgers, and options swap them deliberately.
What does Industrial Systems cover?
Energy where products are made: industrial processes and their energy profiles, compressed air, pumping and fan systems in plant settings, process heating, waste-heat recovery, and the utility systems that serve production. Industrial items are scenario-heavy — a plant, a symptom, a utility bill — and reward practical, plant-floor reasoning about where energy goes in a process and which losses are worth chasing first.
How should you prepare for Industrial Systems? Prepare by system, not by factory: compressed air, steam, pumping, and process heat recur across industries, and the examination tests the systems, not the products being made.
In compressed air, the leak is the lesson: an option that generates air more efficiently while the distribution leaks is treating supply for a demand-side disease.
What does Energy Rates, Tariffs and Supply Options cover?
What energy actually costs: rate structures and tariffs, demand charges and ratchets, time-of-use pricing, load factor as a billing fact as well as an engineering one, and the supply options — procurement choices, contracts, and arrangements — available to a large energy user. Tariff misunderstanding quietly destroys project economics, and this subject exists to catch it: a saving calculated against the wrong rate element is not a saving.
How should you prepare for Energy Rates, Tariffs and Supply Options? Rebuild a bill from its elements — consumption, demand, ratchet, riders, time periods — until each element’s behaviour is predictable. Tariff items are arithmetic with consequences.
Demand is not consumption: an option that cuts kilowatt-hours at the peak hour can be worth more than a larger cut spread across the night, and items price both.
What does Lighting Systems cover?
Light measured and managed: illuminance and footcandles, lumens and efficacy, lighting power density, the quality questions behind the quantities, controls and daylighting, and retrofit savings calculated honestly — wattage, hours, and the interaction effects a careful energy manager does not forget. Lighting is the classic first retrofit, and the subject tests whether the candidate can quantify it rather than merely recommend it.
How should you prepare for Lighting Systems? Practise the retrofit calculation end to end — existing load, proposed load, operating hours, controls effect — because lighting items compress that whole chain into a single question.
Hours are half the calculation: a controls option that halves operating hours can match a technology option that halves wattage, and the better answer depends on which the stem gives you.
What does Boiler and Steam Systems cover?
Heat in its industrial form: boiler types and efficiency, steam distribution and its losses, steam traps and their failure modes, condensate return and why it is worth money twice — heat and treated water — insulation, and flash steam. Steam items reward candidates who follow energy and water together and who know that a failed trap is a continuous loss, not a minor maintenance note.
How should you prepare for Boiler and Steam Systems? Learn the loss inventory: stack, blowdown, radiation, failed traps, lost condensate. Items name a symptom — rising fuel use, water hammer, a cold process — and ask which loss explains it.
Condensate returned is fuel unburned: an option that returns condensate beats an equal option that discards it, on heat, water, and treatment cost at once.
What does Distributed Generation and Renewable Energy Systems cover?
Generating at or near the point of use: on-site generation and combined heat and power, solar and other renewable systems, how distributed resources interact with tariffs and demand, and the judgment of when generating beats buying — a judgment that is economic and operational before it is environmental. Items place a facility, a load profile, and a rate structure in front of the candidate and test the match among the three.
How should you prepare for Distributed Generation and Renewable Energy Systems? Prepare the matching logic: generation earns its case when its output coincides with load and with priced demand. A system sized or timed against the wrong profile fails on paper exactly as it would on site.
Coincidence is the criterion: output that arrives when the facility and the tariff need it is worth more than larger output that arrives when neither does.
What does Energy Storage Systems cover?
The smallest subjects are still examinable in full, and storage is one of them: thermal and electrical storage, charging and discharging against load profiles and price signals, peak shaving and load shifting, and storage paired with generation. Storage items test timing judgment — energy moved in time rather than saved outright — and the arithmetic of peaks, because a battery or a chilled-water tank earns its return against the demand charge it removes.
How should you prepare for Energy Storage Systems? Think of storage as a time machine with losses: energy bought or made at one hour, delivered at another, minus what the round trip costs. Items test whether the delivered value exceeds that cost.
Shaving and shifting are different promises: shaving cuts the peak itself, shifting moves use off it — options that confuse the two misprice the system.
What does Energy Savings Performance Contracting and Measurement and Verification cover?
How savings are contracted and proven: energy savings performance contracting — its structure, its savings commitments, and the sharing of risk between owner and provider — and measurement and verification, including the IPMVP options A through D and the judgment of which option fits which measure. This subject closes the profession’s loop: a saving that cannot be measured to an agreed method cannot be contracted for, committed to, or trusted.
How should you prepare for Energy Savings Performance Contracting and Measurement and Verification? Learn the IPMVP options by their measurement boundary — the fixture, the system, the whole facility, the calibrated model — because items test the fit between measure and method, not the letters.
The baseline is the contract: every M&V dispute is a baseline dispute, and the option that protects the baseline protects the saving.
How is Certified Energy Manager scored?
AEE’s Candidate Handbook states a minimum score of 700 points to pass. That is the whole of what AEE publishes: AEE does not publish the point scale behind the 700, and it does not publish a percent-correct equivalent — so this page prints the standard exactly as AEE states it and converts it into nothing. Candidates should treat any source that turns the 700 points into a percentage as inventing a figure AEE has not given. The practical reading is about preparation shape instead: because the standard cannot be reverse-engineered into a question count, the only sound strategy is breadth with fluency — every subject learned, and the calculation methods practised until they are fast, across all fourteen subjects.
How should you read your practice results?
An overall practice score is the least useful number a candidate owns. The useful reading is by area: which areas of the outline are secure, which are inconsistent — right on recall, wrong on application — and which are simply thin. Each pattern has a different repair. A secure area needs only maintenance in mixed practice. An inconsistent area needs slower work on the reasoning its items demand, with every miss examined for the feature of the situation that was underweighted. A thin area needs study before drilling, because drilling untaught material rehearses guessing. Revisit each repaired area after a gap of several days, in mixed practice, so that retention — not recognition of recently seen material — is what carries the result. That discipline, applied across the whole outline, is what turns a bank of practice questions into readiness for a sitting whose questions the candidate has never seen.
A study plan that follows the outline
- Start with the money subjects. Energy Accounting and Economics plus Energy Rates, Tariffs and Supply Options decide whether you can do the examination’s financial mathematics fluently — payback, NPV, IRR, life-cycle cost, load factor, and demand billing appear inside other subjects’ questions as well.
- Build the technical core next. HVAC Systems and Building Envelope is the largest subject; pair it with Electrical Power Systems and Motors and take each subject’s practice as you finish it.
- Then work the field subjects. Audits and Instrumentation, Boiler and Steam, Industrial Systems, Lighting, Storage, and Distributed Generation reward practical reasoning built on the core.
- Finish with the frameworks, then simulate. Policies and Codes, Controls, Operations and Commissioning, and Performance Contracting and M&V supply the management context — then sit full 130-question practice under the four-hour clock.
Frequently asked questions
How many questions are on the CEM exam, and how long is it? 130 multiple-choice and true/false questions in 4 hours, open book. Of the 130, 120 are scored and 10 are unscored trial questions placed at random, so answer every question as if it counted. This program builds the U.S. version of the examination.
What score passes the CEM exam? AEE’s Candidate Handbook states a minimum score of 700 points. AEE does not publish the point scale or a percent-correct equivalent, and this page does not convert the standard into one.
Is the exam really open book? Yes — open book and open notes, but only printed reference materials organized and bound, plus a stand-alone calculator with no internet capability. Phones, laptops, and tablets are prohibited, and you may not write in your materials during the examination.
Does PassProfessor practice match that format? No, and this page does not claim that it does. The real examination is open book and includes true/false items; PassProfessor practice is closed-resource, four-option multiple choice throughout — stricter on recall and method fluency by design.
Can I take the exam without the experience? Through the EMIT route, if you meet the education side: attend an approved training program and pass the same examination. The Energy Manager In-Training designation is valid for 6 years while your related experience accrues; the full CEM follows when the experience requirement is met.
Is training really required? Yes. AEE requires every candidate to attend an AEE-approved training program — the application asks for your training information.
What does the exam cost? AEE publishes U.S. fees of $500 for application and examination, $250 for a retest, and $300 to renew every 3 years. Confirm the current fees when you apply; those are AEE’s fees, separate from any preparation program.
What happens if I do not pass? A retest carries a minimum 60-day wait. Scores are kept on file for 3 years, and applicants have 3 years to complete their certification file.
Which subjects carry the most weight? HVAC Systems and Building Envelope, at a published range of 10 to 16 percent. Energy Audits and Instrumentation, Electrical Power Systems and Motors, and Operations, Maintenance and Commissioning follow at 7 to 11 percent each. AEE publishes ranges rather than fixed counts, and every subject appears on the examination.
How calculation-heavy is the exam? Calculation is central: energy accounting and economics, unit conversions, load factors, three-phase power and power factor, motor and affinity-law calculations, HVAC and envelope arithmetic, lighting retrofit savings, and tariff and demand calculations. Sound preparation drills the methods until set-up is immediate.
What frameworks should I recognize? The Body of Knowledge works with ASHRAE 90.1 and 62.1 awareness, the ASHRAE audit levels, ISO 50001 energy management, ENERGY STAR and Portfolio Manager benchmarking, and the IPMVP measurement and verification options — what each is and how it is used, never a specific code section number.
What changed in Body of Knowledge 2.0? Decarbonization and climate content, including greenhouse gas accounting across scopes 1, 2, and 3, electrification, and carbon metrics, sits inside the Policies, Codes and Standards subject — one reason preparation built to an older outline no longer suffices.
How long has the CEM existed? AEE established the credential in 1981, and the program is accredited by the ANSI National Accreditation Board under ISO/IEC 17024 — a long-running professional certification, examined against a published Body of Knowledge that AEE revises over time.
Disclaimer
PassProfessor is an independent exam-preparation provider; this program is not endorsed by, affiliated with, or sponsored by the Association of Energy Engineers (AEE). Certified Energy Manager and CEM are marks of the Association of Energy Engineers. This program is examination preparation only: the details on this page are drawn from the official sources recorded in the companion guide and are current as of November 2026; AEE’s official publications govern if anything here differs from them. The credential is awarded by AEE alone when its requirements are complete; this program confers no credential.
