The rest of Part B – Practical under AWS B5.1: Procedure and Welder Qualifications (minimum 28%), Mechanical Test and Properties (minimum 8%), NDE (minimum 8%) and Utilization of Specifications and Drawings (minimum 8%). These eight worked questions cover qualification records and coverage, bend and tensile test criteria, choosing a volumetric method, and reading the governing document.
About Part B, stated exactly. The real Part B is a hands-on, open-book examination worked on physical weld replicas with a physical inspection tool kit against the AWS Part B Book of Specifications, at an AWS authorized test center. A question bank cannot reproduce the bench itself. These questions state every specimen reading and acceptance limit in the question text, so you practice the same measurement-and-disposition judgment the examination measures — not the physical specimens.
AWS publishes the passing standard in its own words: “Candidates must achieve a minimum score of 72% on each exam part to obtain the CWI credential.” There is no averaging across parts — each part is passed on its own line.
1. A welder qualification test record lists the process, material, thickness, filler metal, test results, and inspector signature, but the entry for the position tested was left blank. A supervisor wants to assign the welder to vertical groove work based on this record. What is wrong with relying on this record for that assignment?
A. Nothing is wrong, because position can be assumed from the thickness entry
B. The position tested is not recorded, so the record cannot show that vertical work was ever qualified
C. The record is invalid because it lists the filler metal in full words
D. The record needs a second tensile test before any assignment is made
Correct: B. Position coverage can only be claimed from a record that states the position actually tested, and that entry is blank. Assuming a position from thickness or other entries would fabricate qualification coverage.
2. A welder passed a SMAW plate groove test in the 3G and 4G positions. The governing specification states that a passed groove test also qualifies the welder for fillet welds in the same positions as the groove qualification. The welder is assigned a vertical fillet weld. Is the welder qualified for this assignment?
A. Yes, because the passed groove tests cover fillet welds in the same positions, including vertical
B. No, because fillet welds always require a separate fillet-only test
C. No, because groove tests qualify only groove welds of the same thickness
D. Yes, but only for overhead fillets and not vertical fillets
Correct: A. The stated rule extends a passed groove qualification to fillet welds in the same positions, and vertical was one of the groove positions earned. No separate fillet test is required under that rule.
3. A procedure test coupon was welded in the 1G position only. The governing sample specification states that, for this application, a 1G procedure test supports a WPS for flat-position welding only. The proposed WPS claims all positions. Is the WPS claim supported by this PQR?
A. Yes, because procedure tests are never position-limited
B. Yes, if individual welders hold all-position qualifications
C. No, because the stated support from this test is flat position only, so the all-position claim exceeds the PQR
D. Yes, because the coupon passed its bend tests
Correct: C. Procedure support and welder position coverage are separate questions, and here the stated PQR support is flat only. Qualified welders cannot widen a procedure beyond what its test supports.
4. A welder passed two SMAW plate groove tests, one in the 3G position and one in the 4G position, both recorded. The governing specification states that 3G qualifies flat, horizontal, and vertical groove work, and 4G qualifies flat and overhead groove work. The welder is assigned a horizontal plate groove weld. Is the welder qualified?
A. No, because horizontal work is covered only by a 2G test
B. Yes, because the recorded 3G qualification includes horizontal groove work under the stated coverage
C. No, because two partial tests can never be combined on one record
D. Yes, but only because the 4G test was also passed
Correct: B. Horizontal is expressly inside the stated 3G coverage, so the assignment is covered by that test alone. Separate tests on one welder’s record each contribute their own stated position coverage.
5. A guided bend specimen shows a single open discontinuity 1/8 in. long on the convex surface after bending. The sample specification rejects a specimen when any single open discontinuity exceeds 1/8 in., and corner cracks under 1/4 in. not caused by a flaw are disregarded. The crack is mid-face, not at a corner. What is the result?
A. The specimen passes because the discontinuity does not exceed the 1/8 in. limit
B. The specimen fails because any visible opening is rejectable
C. The specimen fails because mid-face cracks are judged at half the corner limit
D. The result is decided by measuring the specimen thickness instead
Correct: A. The limit rejects discontinuities that exceed 1/8 in., and this one measures exactly 1/8 in. on the face where the limit applies. It therefore meets the stated criterion.
6. A bend specimen shows three small open discontinuities measuring 1/32 in., 1/16 in., and 1/32 in. The specification limits any single discontinuity to 1/8 in. and limits the sum of discontinuities between 1/32 in. and 1/8 in. to 1/4 in. total. What is the result?
A. Fail, because three openings are present
B. Fail, because the sum reaches 3/8 in.
C. Pass, because no single opening exceeds 1/8 in. and the sum is 1/8 in., within the 1/4 in. total
D. Pass only after the openings are counted again after straightening
Correct: C. The individual sizes are 0.031, 0.063, and 0.031 in., summing to 0.125 in., which is within the 0.250 in. total allowed. No single opening exceeds its limit either.
7. A completed butt weld in 1 in. plate must be checked for internal slag inclusions and incomplete penetration through the full volume, and both sides plus the weld faces are accessible. Which volumetric method pair is appropriate for this examination?
A. Liquid penetrant or magnetic particle testing
B. Visual testing with a fillet gauge only
C. Leak testing with a vacuum box
D. Radiographic or ultrasonic testing, because only volumetric methods examine the interior
Correct: D. Internal discontinuities require a method whose energy passes through the weld volume. Radiography and ultrasonics do this, while penetrant and magnetic particle methods address surface and near-surface conditions.
8. A drawing carries the general note: ‘All fillet welds shall be 1/4 in. minimum unless otherwise specified on the drawing.’ A particular joint detail on the same drawing shows no fillet size at all. What size fillet is required at that joint?
A. No weld is required where no size is shown
B. The welder chooses any convenient size
C. 3/8 in., as a safe default for all work
D. 1/4 in., because the general note supplies the size when a detail does not specify otherwise
Correct: D. General notes are part of the drawing requirements and fill in values that individual details leave unstated. The exception phrase matters: a different size shown on a detail would override the note for that joint only.
Keep going: the full program — 1,500 original questions across all 21 B5.1 content areas, 21 area drills and a full timed Part A simulation — is the AWS Certified Welding Inspector (CWI) Exam Prep course. Read the AWS CWI exam guide for the format, eligibility and passing standard in full, try the free 20-question sample, or enroll for $79 with 6 months of access.
Disclaimer
PassProfessor is an independent exam-preparation provider. This program is exam preparation only: it is not the real exam, it provides no education credit, and completing it does not by itself qualify you for any license or certification. The real exam is run by its own exam body — you register for it, pay its fees, and sit it through that body, not through PassProfessor. All practice questions in this program are original; they are not actual exam questions.